1、Designation: C1392 00 (Reapproved 2009)Standard Guide forEvaluating Failure of Structural Sealant Glazing1This standard is issued under the fixed designation C1392; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers a screening approach to detect failure(adhesive or cohesive) of a structural sealant in a structuralsealan
3、t-glazed window, curtain wall, or other similar system.Presently, only a silicone-sealant that is specifically formu-lated, tested, and marketed as a structural glazing sealant isallowed for structural sealant glazing.1.2 The values stated in either acceptable metric units or inother units shall be
4、regarded separately as the standard. Thevalues stated in each system may not be exact equivalents;therefore, each system must be used independently of the other,without combining values in any way.1.3 There are no ISO standards similar or equivalent to thisASTM standard.1.4 This standard does not pu
5、rport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C
6、717 Terminology of Building Seals and Sealants3. Terminology3.1 Definitions: Refer to Terminology C717 for the follow-ing definitions and description of terms used in this guide:adhesive failure; cohesive failure; deflection; glazing; joint;lite; modulus; silicone sealant; structural sealant; struct
7、uralsealant glazing; and substrate.3.1.1 qualified authority, na person with a recognizeddegree or professional certificate and extensive knowledge andexperience in the particular fields necessary for the evaluationprogram. The authoritys qualification level that is necessary tospecify the evaluatio
8、n criteria and interpret the significance ofthe results depends upon the level of sophistication of theevaluation program. For example, if statistical and finiteelement analyses are being incorporated into the evaluationprogram, then the authority should be knowledgeable andexperienced in these area
9、s.3.1.2 competent person, na person experienced in theoperation of the testing equipment and with an understandingof the construction of the wall system. This person may carryout the field testing under the supervision of the qualifiedauthority.4. Summary of Guide4.1 This guide uses deflection measu
10、rements obtained fromlocalized applied loads to determine locations of sealant failurein an installed structural sealant glazing system.4.2 Initially, the deflection of an existing lite that is fullyadhered by a structural sealant is measured when a discreteedge of the lite is loaded laterally. Subs
11、equently, at a fewselected lites, the structural sealant is cut intentionally tosimulate failure, and the deflection of the lite is measured at thesame lateral load. This provides the basis for determiningduring subsequent tests of other lites in the system whether thesealant has failed.4.3 Addition
12、al lites are evaluated and their deflectionsmeasured to determine the extent of any structural sealantfailure. Structural sealant failure is determined by comparingthe measured deflections with the initial measurements ofdeflection with and without failed (intentionally cut) sealant.5. Significance
13、and Use5.1 This guide suggests a simple means of evaluating theextent of any failure of a structural sealant in an installedstructural sealant glazing system.5.2 A qualified authority should specify the criteria de-scribed in Sections 8 and 9 and should interpret the results andjudge their significa
14、nce for the structural sealant glazingsystem.5.3 The evaluation program measures deflection of loadedlites and does not measure directly any structural sealantfailure. Consequently, the qualified authority interpreting thedata should also evaluate the source of any increased deflectionthat is measur
15、ed. Increased deflection may be due to structural1This guide is under the jurisdiction ofASTM Committee C24 on Building Sealsand Sealants and is the direct responsibility of Subcommittee C24.10 on Specifi-cations, Guides and Practices.Current edition approved Dec. 1, 2009. Published December 2009. O
16、riginallyapproved in 1998. Last previous edition approved in 2005 as C1392 00(2005).DOI: 10.1520/C1392-00R09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the sta
17、ndards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.sealant adhesive or cohesive failure, but may also be due to adecrease in sealant modulus, a change in sealant joint dimen-sions, or othe
18、r nonfailure mechanisms. Selective destructivesampling of areas with increased deflections can assist in thisevaluation.6. Suggested Apparatus6.1 Field Loading Device, provides a frame that can spanbeyond the edges of the loaded lite, while supported by suctioncups on the face of adjacent lites or b
19、y other means that do notadversely affect the stresses in the tested structural sealant andlite (Fig. 1 and Fig. 2). To permit application of a forceperpendicular to the surface of the lite, mount a loading pistonon the lite, with a suction cup or other means near the edge ofthe lite. Place a load c
20、ell between the suction cup and the frameto monitor the applied load. Calibrate the field loading deviceand the load cell prior to use on a project and immediately afterany changes or damage to the device.6.2 Deflection Measurement Device, either an extensometerwith a dial gage mounted on an adjacen
21、t lite or a straight edgewith feeler gages, of length equal to the length of the edge ofthe lite. The device should be accurate to within 10 % of themeasured deflection.7. Sampling7.1 The qualified authority should specify the locations,distribution, and number of applied loads for the structuralsea
22、lant glazing system. Sections 8 and 9 discuss variousapproaches to this selection process.8. Establishing Deflection and Sealant FailureRelationship8.1 Summary of ProcedureEstablishing the deflection/failure relationship requires the specifying authority to selectthe applied load magnitude, the loca
23、tions of the applied loadson the lite, and the criteria for failure length. The followingdescribes various approaches that can be used to select theseparameters, depending upon the sophistication of the evalua-tion program and the desired results. Depending upon theparameters selected the procedure
24、can be used as a crudescreening tool or can be correlated to the actual stresses withinthe structural sealant joint under an applied load and used as arational means of assessing areas of failure that require repair.Using the deflection magnitudes and locations, the initialevaluation establishes the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC139220002009STANDARDGUIDEFOREVALUATINGFAILUREOFSTRUCTURALSEALANTGLAZING 评价 构造 密封 门窗 玻璃 破坏 标准 指南

链接地址:http://www.mydoc123.com/p-464455.html