ASTM C1387-2014 Standard Guide for the Determination of Technetium-99 in Soil《土壤里锝99的测定的标准指南》.pdf
《ASTM C1387-2014 Standard Guide for the Determination of Technetium-99 in Soil《土壤里锝99的测定的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1387-2014 Standard Guide for the Determination of Technetium-99 in Soil《土壤里锝99的测定的标准指南》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1387 14Standard Guide forthe Determination of Technetium-99 in Soil1This standard is issued under the fixed designation C1387; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in par
2、entheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide is intended to serve as a reference forlaboratories wishing to perform99Tc analyses in soil. Severaloptions are given for selection of a
3、tracer and for the method ofextracting the Tc from the soil matrix. Separation of Tc fromthe sample matrix is performed using an extraction chroma-tography resin. Options are then given for the determination ofthe99Tc activity in the original sample. It is up to the user todetermine which options ar
4、e appropriate for use, and togenerate acceptance data to support the chosen procedure.1.2 Due to the various extraction methods available, varioustracers used, variable detection methods used, and lack ofcertified reference materials for99Tc in soil, there is insufficientdata to support a single met
5、hod written as a standard method.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user o
6、f this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C859 Terminology Relating to Nuclear MaterialsC998 Practice for Sampling Surface Soil for RadionuclidesC999 Practic
7、e for Soil Sample Preparation for the Determi-nation of RadionuclidesD1193 Specification for Reagent WaterD7168 Test Method for99Tc in Water by Solid Phase Extrac-tion DiskE11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Terminology3.1 For definitions of terms in this guide, refer
8、to Terminol-ogy C859.4. Summary of Guide4.1 There are no stable isotopes of technetium.Technetium-99 is produced by the fission of uranium andplutonium, and has been released to the environment vianuclear weapons testing and nuclear materials processing. Inan oxidizing environment, it exists as the
9、very mobile pertech-netate ion, TcO4. Technetium-99 is a long-lived (half-life of2.1 E 5 years), weak beta (maximum beta energy of 293 keV)emitting radioisotope.4.2 For the analysis of99Tc in soil, a tracer is added to thesample matrix, or spiked duplicate samples are prepared, andthen the Tc is ext
10、racted from the soil matrix by one of severalmethods, including acid leaching or one of various fusionmethods. The resulting solution is passed through an extractionchromatography column. Technetium is known to be retainedby the extraction chromatography material while most otherelements pass throug
11、h the column. The column is washed withdilute acid to remove any remaining interferents. The resinmay then be counted directly by adding it to a liquid scintil-lation cocktail and counting by liquid scintillationspectrometry, or the Tc may be eluted from the resin foralternative counting or mass spe
12、ctrometric techniques.5. Significance and Use5.1 This guide offers several options for the determinationof99Tc in soil samples. Sample sizes of up to 200 g arepossible, depending on the method chosen to extract Tc fromthe soil matrix. It is up to the user to determine if it isappropriate for the int
13、ended use of the final data.6. Interferences6.1 Any radionuclide not completely removed by the ex-traction chromatography column that has a beta decay energysimilar to or higher than99Tc will interfere when countingtechniques are used for quantification of the99Tc activity.6.2 Any elements with a ma
14、ss-to-charge ratio (m/z) of 99(that is, naturally occurring isotope of99Ru or other artificiallyproduced elements of sufficient half-life with similar m/z) caninterfere when using mass spectrometry for quantification of1This guide is under the jurisdiction of ASTM Committee C26 on Nuclear FuelCycle
15、and is the direct responsibility of Subcommittee C26.05 on Methods of Test.Current edition approved Jan. 1, 2014. Published February 2014. Originallyapproved in 1998. Last previous edition approved in 2008 as C1387 08. DOI:10.1520/C1387-14.2For referenced ASTM standards, visit the ASTM website, www.
16、astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1the99Tc
17、 mass activity. Any element with the same m/z as theisotope used as an isotope dilution tracer or internal standardwill cause a bias in the yield correction. Corrections should beincluded in the mass spectrometry data reduction for knowninterferences.6.3 Additional interferences may be encountered,
18、depend-ing on the tracer and measurement technique chosen. It is up tothe user to determine and correct for any additional interfer-ences.7. Apparatus7.1 Apparatus for the Extraction of Tc from Sample Matrix:7.1.1 See the individual extraction method descriptions tocompile a list of the equipment ne
19、eded for the chosen extrac-tion method.7.2 Apparatus for the Purification of Tc from the SoilExtract:7.2.1 Extraction columnwith a bed volume of severalmilliliters for the extraction chromatography resin.37.2.2 Column extension funnelsthat can be added to theextraction column such that a few hundred
20、 milliliters ofsolution can be added to the column at one time.7.2.3 Column rackholds columns such that several extrac-tions can be performed simultaneously.7.3 Apparatus for the Quantification of99Tc:7.3.1 See the individual detection method descriptions tocompile a list of the equipment needed for
21、 the chosen detectionmethod.8. Reagents8.1 Purity of ReagentsAll chemicals should, at aminimum, be of reagent grade and should conform to thespecifications of the Committee on Analytical Reagents of theAmerican Chemical Society where such specifications areavailable.4High Purity reagents are suggest
22、ed if mass spec-trometry is chosen as the detection method. Other grades ofreagents may be used provided it is first determined that thereagent is of sufficient purity to permit its use without lesseningthe accuracy of the determination.8.2 Purity of WaterUnless otherwise indicated, referencesto wat
23、er shall be understood to mean reagent water, as definedby Type I of Specification D1193.8.3 Tracer:8.3.1 Isotope Dilution Yield Determination:8.3.1.1 Radiometric Yield Determination95mTc5or99mTc6have been used to monitor the chemical yield of the extractionand purification of99Tc prior to quantific
24、ation. Example: Add10 nCi of99mTc as a yield tracer when determining yield bygamma spectrometry.8.3.1.2 Mass Spectrometric Yield Determination97Tc maybe produced in a nuclear reactor in very limited quantities to beused as an isotope dilution tracer for the mass spectrometricdetermination of99Tc (1)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13872014STANDARDGUIDEFORTHEDETERMINATIONOFTECHNETIUM99INSOIL 土壤 99 测定 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-464448.html