ASTM C1269-1997(2003) Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors《内置穿过式金属探测器操作灵敏度设置调整的标准规程》.pdf
《ASTM C1269-1997(2003) Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors《内置穿过式金属探测器操作灵敏度设置调整的标准规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1269-1997(2003) Standard Practice for Adjusting the Operational Sensitivity Setting of In-Plant Walk-Through Metal Detectors《内置穿过式金属探测器操作灵敏度设置调整的标准规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1269 97 (Reapproved 2003)Standard Practice forAdjusting the Operational Sensitivity Setting of In-PlantWalk-Through Metal Detectors1This standard is issued under the fixed designation C 1269; the number immediately following the designation indicates the year oforiginal adoption or, i
2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONNuclear regulatory authorities require personnel entering designated security are
3、as to be screenedfor concealed weapons. Additionally, in security areas containing specified quantities of specialnuclear materials, personnel exiting the facility are required to be screened for metallic nuclearshielding material. Walk-through metal detectors are widely used to implement these requ
4、irements.Nuclear regulatory authorities usually specify an assortment of metal detector test objects that mustall be detected by walk-through metal detectors. This practice provides a procedure for adjusting theoperational sensitivity setting to the lowest setting necessary to detect the least likel
5、y to-be-detectedtest object in its least likely to-be-detected orientation while passing through the detection zone in theweakest known detection path. All other test objects will then be detected at this sensitivity settinganywhere in the detection zone.1. Scope1.1 This practice covers a procedure
6、for adjusting theoperational sensitivity of in-plant walk-through metal detec-tors. Performance of this procedure should result with in-plantwalk-through metal detectors being adjusted to an initialoperational sensitivity setting suitable for performance testing.1.2 This practice does not set test o
7、bject specifications orspecify specific test objects. These should be specified by theregulatory authority.1.3 This practice uses information developed by PracticeC 1270, or an equivalent procedure, which identifies thecritical test object (from a specified set of test objects), itscritical orientat
8、ion, and the critical test path through thedetection zone. In the case of Practice C 1270, the informationis found on the detection sensitivity map(s) for each in-plantwalk-through metal detector.1.4 This practice is one of several developed to assistoperators of nuclear facilities with meeting the
9、metal detectionperformance requirements of the regulatory authorities (seeAppendix).1.5 This standard practice is neither intended to set perfor-mance levels nor limit or constrain technologies.1.6 This practice does not address safety or operationalissues associated with the use of walk-through met
10、al detectors.1.7 The values stated in SI units are to be regarded asstandards. The values given in parentheses are for informationonly.2. Referenced Documents2.1 ASTM Standards:C 1238 Guide for Installation of Walk-Through Metal De-tectors2C 1270 Practice for Detection Sensitivity Mapping of In-Plan
11、t Walk-Through Metal Detectors2C 1309 Practice for Performance Evaluation of In-PlantWalk-Through Metal DetectorsF 1468 Practice for the Evaluation of Metallic WeaponsDetectors for Controlled Access Search and Screening33. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 clean-tes
12、ter, na person who does not carry anyextraneous metallic objects that would significantly alter thesignal produced when the person carries a test object.3.1.1.1 DiscussionSmaller test objects require more com-plete elimination of metallic objects. By example but notlimitation, such extraneous metall
13、ic objects may include:metallic belt buckles, metal buttons, cardiac pacemakers, coins,metal frame eyeglasses, hearing aids, jewelry, keys, mechani-cal pens and pencils, shoes with metal shanks or arch supports,metallic surgical implants, undergarment support metal, metal1This practice is under the
14、jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.12 on SafeguardApplications.Current edition approved Dec. 10, 1997. Published June 1998. Originallyapproved in 2000. Last previous edition approved in 1997 as C 1269 97.2Annual Book of ASTM S
15、tandards, Vol 12.01.3Annual Book of ASTM Standards, Vol 15.07.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.zippers, etc. In the absence of other criteria, a clean testerpassing through a metal detector shall not cause a disturbanc
16、esignal greater than 10 % of that produced when carrying thecritical test object through the detector. Test objects requiringmore complete elimination of extraneous metal to obtain lessthan 10 % signal disturbance.3.1.1.2 DiscussionThe tester shall have a weight between50 to 104 kg (110 to 230 lb) a
17、nd a height between 1.44 to 1.93m (57 to 75 in.). Should a given detector be sensitive to bodysize because of design or desired sensitivity, the physical sizeof testers should be smaller and within a narrower range.3.1.1.3 DiscussionIt is recommended that the clean testerbe surveyed with a high sens
18、itivity hand-held metal detector toensure that no metal is present.3.1.2 critical orientationthe orthogonal orientation of atest object that produces the smallest detection signal orweakest detection anywhere in the detection zone; the orthogo-nal orientation of a test object that requires a higher
19、sensitivitysetting to be detected compared to the sensitivity settingsrequired to detect the object in all other orthogonal orienta-tions. See Fig. 1 for handgun orientations3.1.2.1 DiscussionCritical orientations are determined bytesting using a mapping procedure such as described inPractice C 1270
20、.3.1.2.2 DiscussionThe term critical orientation can beapplied in two ways. Critical orientation can refer to the worstcase orthogonal orientation in a single test path or the worstcase orthogonal orientation for all the test paths (the entiredetection zone). The two are coincident in the critical t
21、est path.3.1.3 critical sensitivity setting, nthe lowest sensitivitysetting of a detector at which the critical test object in itscritical orientation is consistently detected (10 out of 10 testpasses) when passed through the detection zone on the criticaltest path.3.1.4 critical test element, nsee
22、test element.3.1.5 critical test object, nsee test object.3.1.6 critical test path, nthe straight-line shortest-coursepath through the portal aperture, as defined by an element onthe detection sensitivity map, that produces the smallestdetection signal or weakest detection for the critical test obje
23、ctin its critical orientation. (see Figs. 2 and 3)3.1.7 detection sensitivity map, n(see Fig. 2) a depictionof the grid used to define test paths through the detection zonewith each element of the grid containing a value, usually thesensitivity setting of the detector, that is indicative of thedetec
24、tability of the test object.3.1.7.1 DiscussionThese values are relative and describethe detection sensitivity pattern within the detection zone forthe specific test object. The values are derived by identicallytesting each defined test path using a specific test object in aFIG. 1 Six Standard Orthog
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC126919972003STANDARDPRACTICEFORADJUSTINGTHEOPERATIONALSENSITIVITYSETTINGOFINPLANTWALKTHROUGHMETALDETECTORS

链接地址:http://www.mydoc123.com/p-464005.html