1、Designation: C 1266 02 (Reapproved 2007)Standard Test Method forFlow Characteristics of Preformed Tape Sealants1This standard is issued under the fixed designation C 1266; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、 last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes a laboratory procedure fordetermining the flow characteristics of preformed tape sealants
3、after a specified time, temperature, and load.1.2 The values stated in SI units are to be regarded as thestandard. The inch-pound units given in parentheses areprovided for information purposes only.1.3 The committee with jurisdiction of this specification isnot aware of any similar specification wi
4、thin ISO or any otherorganization.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limita
5、tions prior to use.2. Referenced Documents2.1 ASTM Standards:2C 717 Terminology of Building Seals and Sealants3. Terminology3.1 DefinitionsThe definitions of the following terms usedin this test method are found in Terminology C 717: com-pound, seal, sealant, substrate and tape sealant.4. Summary of
6、 Test Method4.1 The tape sealant to be tested is rolled into spherical ballsof equal weight. Four spherical balls are placed between twoaluminum plates, which are then compressed. A standardweight is placed on the test assembly for1hatroomtemperature. The height of the test assembly is measured tode
7、termine the rebound of the sample. The test assembly is thenplaced in an 88C (190F) oven with the standard weight on it.After 24 h the height of the test assembly is measured again todetermine the flow of the sample.5. Significance and Use5.1 Tape sealants are tacky, deformable solids, which areused
8、 under compression between two or more surfaces ofsimilar or dissimilar substrates in a variety of sealing applica-tions. These tapes are normally supplied in a roll form with arelease paper interlever and are hand pressed against a fixedsubstrate. This procedure is designed to give an indication of
9、the flow characteristics of a tape sealant under controlledtemperature and aging conditions with a specified load.6. Apparatus6.1 Aluminum Plates, four, each 6.35 by 76.2 by 101.6 mm(0.25 by 3.00 by 4.00 in.).6.2 Lead Weights, two, each 3.63 kg (8.0 lb) with dimen-sions large enough to cover the ent
10、ire assembly, but notoverhanging the assembly.6.3 Mechanical Convection Oven, capable of maintaining atemperature of 88 6 1C (190 6 2F).6.4 Steel Spacers, six, each 76.2 by 5.08 by 5.08 6 0.05 mm(3.00 by 0.20 by 0.20 6 0.002 in.).6.5 Thickness Gage, having a total capacity of at least 76.2mm (3.00 i
11、n.) graduated in 0.025 mm (0.001 in.) divisions. Thegage shall be equipped to provide a 57 g (2 oz) load over aminimum contact area of 6.35 mm (0.25 in.).6.6 Laboratory Press, at room temperature, to compress thepreformed sealant tape to the proper material thickness.6.7 Stop Watch, to measure the t
12、imed intervals specified inthe laboratory procedure.6.8 Laboratory Precision Balance (capable of weighing to0.1 mg) to measure the weight of the individual spherical ballsof tape.7. Sampling7.1 Samples to be tested shall be taken from a fresh roll oftape sealant taken directly from a randomly select
13、ed commer-cial container as supplied by the manufacturer, after firstremoving and discarding approximately the first 0.61 (2 ft) ofthe roll.1This test method is under the jurisdiction ofASTM Committee C24 on BuildingSeals and Sealants and is the direct responsibility of Subcommittee C24.20 onGeneral
14、 Test Methods.Current edition approved June 1, 2007. Published July 2007. Originally approvedin 1995. Last previous edition approved in 2002 as C 1266 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMS
15、tandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8. Standard Test Conditions8.1 Unless otherwise specified by those authorizing the test,stan
16、dard conditions of temperature and relative humidity shallbe 236 2C (73.4 6 3.6F) and 50 6 5 % respectively.9. Test Assembly Preparation9.1 A total of two assemblies per tape are to be prepared.9.1.1 Prepare a test assembly as follows:9.1.1.1 Clean two aluminum plates with isopropyl alcohol(IPA) or
17、other suitable solvent.9.1.1.2 Using a marking pen, draw intersecting diagonals onone side of both metal plates. On each plate mark four points32 mm (1.25 in.) from the intersection of the diagonals asshown in Fig. 1. These become the top surfaces.9.1.1.3 Stack the plates, and using the thickness ga
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC126620022007STANDARDTESTMETHODFORFLOWCHARACTERISTICSOFPREFORMEDTAPESEALANTS 预制 胶带 密封剂 流动 特性 标准 试验

链接地址:http://www.mydoc123.com/p-463996.html