ASTM C109 C109M-2007e1 Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in or [50-mm] Cube Specimens).pdf
《ASTM C109 C109M-2007e1 Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in or [50-mm] Cube Specimens).pdf》由会员分享,可在线阅读,更多相关《ASTM C109 C109M-2007e1 Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in or [50-mm] Cube Specimens).pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 109/C 109M 071Standard Test Method forCompressive Strength of Hydraulic Cement Mortars (Using2-in. or 50-mm Cube Specimens)1This standard is issued under the fixed designation C 109/C 109M; the number immediately following the designation indicates the yearof original adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1NOTEA typo in
3、5.9.2 was corrected editorially August 2008.1. Scope*1.1 This test method covers determination of the compres-sive strength of hydraulic cement mortars, using 2-in. or50-mm cube specimens.NOTE 1Test Method C 349 provides an alternative procedure for thisdetermination (not to be used for acceptance t
4、ests).1.2 This test method covers the application of the test usingeither inch-pound or SI units. The values stated in either systemshall be regarded separately as standard. Within the text, the SIunits are shown in brackets. The values stated in each systemare not exact equivalents; therefore, each
5、 system shall be usedindependently of the other. Combining values from the twosystems may result in nonconformance with the specification.1.3 Values in SI units shall be obtained by measurement inSI units or by appropriate conversion, using the Rules forConversion and Rounding given in Standard IEEE
6、/ASTM SI10, of measurements made in other units.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of reg
7、ulatory limitations prior to use. (WarningFreshhydraulic cementitious mixtures are caustic and may causechemical burns to skin and tissue upon prolonged exposure.2)2. Referenced Documents2.1 ASTM Standards:3C91 Specification for Masonry CementC114 Test Methods for Chemical Analysis of HydraulicCemen
8、tC 150 Specification for Portland CementC 230/C 230M Specification for Flow Table for Use in Testsof Hydraulic CementC 305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC 349 Test Method for Compressive Strength of Hydraulic-Cement Mortars (Using Portions
9、 of Prisms Broken inFlexure)C511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and ConcretesC 595 Specification for Blended Hydraulic CementsC 618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use
10、in ConcreteC 670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsC 778 Specification for Standard SandC 989 Specification for Ground Granulated Blast-FurnaceSlag for Use in Concrete and MortarsC 1005 Specification for Reference Masses and Devices forDet
11、ermining Mass and Volume for Use in the PhysicalTesting of Hydraulic CementsC 1157 Performance Specification for Hydraulic CementC 1328 Specification for Plastic (Stucco) CementC 1329 Specification for Mortar CementC 1437 Test Method for Flow of Hydraulic Cement MortarIEEE/ASTM SI 10 Standard for Us
12、e of the InternationalSystem of Units (SI): The Modern Metric System3. Summary of Test Method3.1 The mortar used consists of 1 part cement and 2.75 partsof sand proportioned by mass. Portland or air-entrainingportland cements are mixed at specified water/cement ratios.Water content for other cements
13、 is that sufficient to obtain aflow of 110 6 5 in 25 drops of the flow table. Two-inch or50-mm test cubes are compacted by tamping in two layers.1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.27 on Strength.Current edit
14、ion approved Aug. 15, 2007. Published September 2007. Originallyapproved in 1934. Last previous edition approved in 2005 as C 109/C 109M 05.2See the section on Safety, Manual of Cement Testing, Annual Book of ASTMStandards, Vol 04.01.3For referenced ASTM standards, visit the ASTM website, www.astm.o
15、rg, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box
16、C700, West Conshohocken, PA 19428-2959, United States.The cubes are cured one day in the molds and stripped andimmersed in lime water until tested.4. Significance and Use4.1 This test method provides a means of determining thecompressive strength of hydraulic cement and other mortarsand results may
17、be used to determine compliance with speci-fications. Further, this test method is referenced by numerousother specifications and test methods. Caution must be exer-cised in using the results of this test method to predict thestrength of concretes.5. Apparatus5.1 Weights and Weighing Devices, shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC109C109M2007E1STANDARDTESTMETHODFORCOMPRESSIVESTRENGTHOFHYDRAULICCEMENTMORTARSUSING2INOR50MMCUBESPECIMENSPDF

链接地址:http://www.mydoc123.com/p-463320.html