《ASTM C1058 C1058M-2010(2015) Standard Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation《绝热材料热性能评价和报告时温度选择的标准实践规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1058 C1058M-2010(2015) Standard Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation《绝热材料热性能评价和报告时温度选择的标准实践规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1058/C1058M 10 (Reapproved 2015)Standard Practice forSelecting Temperatures for Evaluating and ReportingThermal Properties of Thermal Insulation1This standard is issued under the fixed designation C1058/C1058M; the number immediately following the designation indicates theyear of origi
2、nal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers standard mean temperatures forreporting the
3、rmal properties of thermal insulations, products,and materials, and of related systems and components, bothinsulated and uninsulated.1.2 Thermal properties shall be determined as a function oftemperature by standard test methods. (Test Methods C177,C201, C335/C335M, C518, C745, C1114, C1363, Guide C
4、653,and Practice C687, all in combination with Practice C1045.)NOTE 1Standard referenced materials are needed to span the tem-perature range of the tests.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be
5、exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This practice recommends standard conditions for use intesting and evaluating thermal properties as a function oftemperature by s
6、tandard test methods.1.5 General applications of thermal insulations include:1.5.1 Building envelopes,1.5.2 Mechanical systems or processes, and1.5.3 Building and industrial insulations.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is th
7、eresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat
8、Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC201 Test Method for Thermal Conductivity of RefractoriesC335/C335M Test Method for Steady-State Heat TransferProperties of Pipe InsulationC518 Test Method for Steady-State Thermal TransmissionProperties
9、 by Means of the Heat Flow Meter ApparatusC653 Guide for Determination of the Thermal Resistance ofLow-Density Blanket-Type Mineral Fiber InsulationC687 Practice for Determination of Thermal Resistance ofLoose-Fill Building InsulationC745 Test Method for Heat Flux Through Evacuated Insu-lations Usin
10、g a Guarded Flat Plate Boiloff Calorimeter(Withdrawn 2008)3C1045 Practice for Calculating Thermal Transmission Prop-erties Under Steady-State ConditionsC1114 Test Method for Steady-State Thermal TransmissionProperties by Means of the Thin-Heater ApparatusC1363 Test Method for Thermal Performance of
11、BuildingMaterials and Envelope Assemblies by Means of a HotBox Apparatus3. Terminology3.1 DefinitionsFor definitions of terms and symbols usedin this practice, refer to Terminology C168.1This practice is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibili
12、ty of Subcommittee C16.30 on ThermalMeasurement.Current edition approved March 1, 2015. Published May 2015. Originallyapproved in 1986. Last previous edition approved 2010 as C1058/C1058M 10.DOI: 10.1520/C1058_C1058M-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orconta
13、ct ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, P
14、O Box C700, West Conshohocken, PA 19428-2959. United States14. Significance and Use4.1 The various methods for measuring and calculatingthermal properties provide data and information for manufac-turers published information, for comparison of relatedproducts, and for designers and users to evaluate
15、 insulationproducts for particular applications. For these purposes it isadvisable to provide basic data and information producedunder standard temperature conditions.4.2 It is possible that thermal properties of a specimen willchange with mean temperature, with temperature differenceacross the spec
16、imens, and with high temperature exposure.Data and information at standard temperatures are necessaryfor valid comparison of thermal properties.4.3 The mean test temperatures to measure thermal proper-ties shall be selected from those listed in Table 1.Itisrecommended that thermal properties of insu
17、lation materials beevaluated over a mean temperature range that represents theintended end use. For this situation, the lowest and greatestmean temperatures need to be within 10C of the maximumand minimum mean temperature of interest. The temperaturedifferences for any chosen mean temperature will d
18、epend uponboth the thermal insulation application (see appropriate mate-rials specification), the method of evaluation, and the limita-tions of the apparatus. Temperature differences or relevanttemperature conditions required by ASTM material specifica-tions shall take precedence over those recommen
19、ded in thispractice.4.3.1 Standard conditions are presented where both surfacesare exposed to fixed ambient temperatures that are typical fortesting building constructions, both insulated and uninsulated(Table 2).4.3.2 Standard conditions are presented where the tempera-tures of the two surfaces are
20、 fixed and surface coefficients arenot considered (Table 3).4.3.3 For conditions where the temperature of only onesurface is fixed with the other exposed to fixed ambienttemperature, use the mean temperatures of Table 1.4.4 These conditions must be stated to describe accuratelythermal properties suc
21、h as thermal conductivity versus meantemperature for thermal insulating materials. Thermal insula-tions exhibiting inflection points due to the change of state ofinsulating gases (see Note 2), must be tested at sufficientlysmall temperature differences between (1) the hot and coldsides and (2) betwe
22、en mean temperatures. The test temperaturedifferences used depend on the vapor pressure versus tempera-ture relationship of the gases involved and the ability of the testapparatus to provide accurate measurements of low tempera-ture differences.NOTE 2Certain closed-cell cellular plastic insulations
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1058C1058M20102015STANDARDPRACTICEFORSELECTINGTEMPERATURESFOREVALUATINGANDREPORTINGTHERMALPROPERTIESOFTHERMALINSULATION

链接地址:http://www.mydoc123.com/p-463172.html