ASTM C639-2001(2007) Standard Test Method for Rheological (Flow) Properties of Elastomeric Sealants《弹性密封料流变(流动)特性的标准试验方法》.pdf
《ASTM C639-2001(2007) Standard Test Method for Rheological (Flow) Properties of Elastomeric Sealants《弹性密封料流变(流动)特性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C639-2001(2007) Standard Test Method for Rheological (Flow) Properties of Elastomeric Sealants《弹性密封料流变(流动)特性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 639 01 (Reapproved 2007)Standard Test Method forRheological (Flow) Properties of Elastomeric Sealants1This standard is issued under the fixed designation C 639; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method describes a la
3、boratory procedure forthe determination of rheological (flow) properties of single-and multicomponent chemically curing sealants for use inbuilding construction.1.2 Other suitable flow characteristics may be agreed uponbetween the seller and purchaser or specifier. Special nonsagproperties and lower
4、 flow characteristics may be required foruse in sloping joints where absolute leveling is not desired.NOTE 1The sealants are supplied in various rheological propertiesranging from pourable fluids to stiff nonsagging pastes. Multicomponentsealants are supplied as a base component with an activator or
5、 curingagent separately packaged. After mixing the multiple parts, the sealant isready for application. Single-component sealants are supplied ready foruse upon opening of the package and usually depend on the externalenvironment for cure.1.3 This test method describes four types of joint sealants:1
6、.3.1 Type ISingle-component flowable or self-leveling,1.3.2 Type IISingle-component nonsag,1.3.3 Type IIIMulticomponent flowable or self-leveling,and1.3.4 Type IVMulticomponent nonsag.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informa
7、tiononly.1.5 This standard does not purport to address the safetyproblems associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2
8、.1 ASTM Standards:2C 717 Terminology of Building Seals and Sealants3. Terminology3.1 DefinitionsRefer to Terminology C 717, Section 4.1,for definitions of the following terms used in this standard:chemically curing sealants, compound, elastomeric, flow(slump), non-sag sealant (non-slump), sealant, s
9、elf-levelingsealant (flowable).4. Comparison to Other Standards4.1 ISO 7390:1987 Building Construction-JointingProducts-Determination of Resistance to Flow5. Significance and Use5.1 The results obtained from this test method are simply ameasure of the degree of horizontal or vertical flow ofsingle-c
10、omponent or multi-component sealants when appliedto a set joint configuration at two pre-determined temperatures.Only samples conditioned at the same temperature may bedirectly compared.6. Apparatus6.1 Refrigerator, controlled at 4.4 6 2C (40 6 3.6F).6.2 Oven, convention-type, controlled at 50 6 2C
11、(12263.6F).6.3 Channel, one, stainless steel (Type 304, No. 2-B finish,No. 16 gage), inside dimensions 19 mm wide, 13 mm deep,152 mm long (34 by12 by 6 in.), and closed at both ends (seeFig. 1a).6.4 Channels, two, stainless steel (Type 304, No. 2-B finish,No. 16 gage), inside dimensions 19 mm wide,
12、13 mm deep,152 mm long (34 by12 by 6 in.) with both ends open and theback surface extended 51 mm (2 in.) (see Fig. 1b).7. Standard Test Conditions7.1 Unless otherwise specified, standard conditions shall be23 6 2C (73.4 6 3.6F) and 50 6 5 % relative humidity.8. Procedures8.1 Test for Type I Sealants
13、:8.1.1 Clean the closed-end channel (Fig. 1a) with methylethyl ketone or similar solvent followed by a thorough cleaningwith a detergent solution and a final rinse with distilled ordeionized water, and then air dry.1This test method is under the jurisdiction ofASTM Committee C24 on BuildingSeals and
14、 Sealants and is the direct responsibility of Subcommittee C24.20 onGeneral Test Methods.Current edition approved June 1, 2007. Published July 2007. Originally approvedin 1969. Last previous edition approved in 2001 as C 639 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or
15、contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8.1.2 Before prepa
16、ring the test assembly, condition at least100 g of the compound under test in the unopened container forat least 16 h at standard conditions. Then condition thecompound for 16 to 24 h and the channel for2hinarefrigerator held at 4.4 6 2C (40 6 3.6F). At the end of theconditioning periods, pour the c
17、ompound into the conditionedchannel held horizontally at the latter temperature and maintainthe test specimen at this temperature for 4 h. At the end of thisperiod, examine the compound for flow properties.8.2 Tests for Type II Sealants:8.2.1 Vertical SlumpBefore preparing the test assemblies,condit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC63920012007STANDARDTESTMETHODFORRHEOLOGICALFLOWPROPERTIESOFELASTOMERICSEALANTS 弹性 密封 流变 流动 特性 标准

链接地址:http://www.mydoc123.com/p-507857.html