1、Designation: C 1026 87 (Reapproved 2002)Standard Test Method forMeasuring the Resistance of Ceramic Tile to Freeze-ThawCycling1This standard is issued under the fixed designation C 1026; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the procedures and equip-ment required to test either glazed or unglazed c
3、eramic tile forresistance to repeated cycles of freezing and thawing. Ceramictile of any size or shape may be tested by this test method.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard does not pur
4、port to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 2
5、42 Terminology of Ceramic Whitewares and RelatedProducts2E 220 Method for Calibration of Thermocouples by Com-parison Techniques33. Summary of Test Method3.1 A designated test-load of tile specimens is saturated withwater, and placed in a freezer with thermocouples (thermom-eter) inserted. Freezing
6、is followed by a thawing cycle with thespecimens immersed in water. The number of tile damagedafter freezing and thawing for 5, 10, and 15 cycles isdetermined by visual examination.4. Significance and Use4.1 The test for resistance to freezing and thawing functionsas a guide to the selection of cera
7、mic tile suitable for outdoorservice in geographic areas subjected to freezing. It can serveas a test method to verify compliance with specifications forceramic tile, and provides a control test for determining theuniformity of tile being manufactured for exterior installations.5. Apparatus (See Fig
8、. 1)5.1 The freezing chamber for this test method may be ofanytype provided it has the capacity to cool the center of the testload to 0F (18C) within a period of 6 to 8 h. By adjustingthe mass of the test load, freezers with various freezing ratesmay be used in this test as long as the 6 to 8-h peri
9、od to reach0F (18C) is maintained.5.2 Two freezer thermometers of the type that use a ther-mocouple are required. They shall be calibrated to 0F (18C)against a thermometer of known accuracy (see 2.1).5.3 Vacuum Chamber, capable of withstanding a vacuum of760 mm Hg (102 MPa).5.4 Vacuum Pump, that can
10、 go down to 20 mm Hg (2.6MPa) pressure.5.5 Drill Press.5.6 Carbide Tipped Bit, slightly larger in diameter than thethermocouple, or other means of drilling the tile.5.7 Ultraviolet Light Source and Fluorescent Dye, (un-glazed tile) or black ink (glazed tile).6. Test Samples6.1 Select ten samples at
11、random from the lot to be tested.7. Procedure7.1 Calibration of the Freezer Capacity:7.1.1 Calibrate the two freezer thermometers.7.1.2 Select a group of tiles having the same approximateabsorption, size, and total mass as the samples to be used in thefinal test for use as a test load.7.1.3 Drill a
12、hole through the center of the tile that will bein the middle of the load as it is placed in the freezer in orderto accommodate the thermocouple. The fit of the thermocouplebead in the tile should be as snug as possible. The wire shouldbe trailed out either between the ribs or in a slot cut in the b
13、ackof one of the tiles. It is important that the tile, when stacked, arenot held apart by the thermocouple or wire.7.1.4 Remove the thermocouple from the prepared tile andsubject them and the remainder of the tile to be used as the testload to the following:1This test method is under the jurisdictio
14、n of ASTM Committee C21 on CeramicWhitewares and Related Productsand is the direct responsibility of SubcommitteeC21.06on Ceramic Tile.Current edition approved Sept. 25, 1987. Published November 1987. Originallypublished as C-21 Proposed Test Method P 153. Last previous edition C 1026 84.2Annual Boo
15、k of ASTM Standards, Vol 15.02.3Annual Book of ASTM Standards, Vol 14.03.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.2 Test Load Preparation:7.2.1 Place as many tile at a time as possible in a vacuumcontainer. Evacuate to a pre
16、ssure of 20 mm Hg for 20 min, thenadd potable water at room temperature to cover the tilecompletely while still under vacuum. Hold under vacuum for40 min. Make sure all tile are submerged in water throughoutthe 40-min soak. After this treatment, release the vacuum andstore the treated tile immersed
17、in water until ready for 7.2.3.7.2.2 Mount the thermometers to the outside of freezingchamber which has a no-load capability of 10 to 20F (23to 29C). Place one thermocouple in the freezer sothat it issuspended in the atmosphere of the freezer, not touching thesides or bottom. The other thermocouple
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC102619872002STANDARDTESTMETHODFORMEASURINGTHERESISTANCEOFCERAMICTILETOFREEZETHAWCYCLING 测定 瓷砖 耐冻熔

链接地址:http://www.mydoc123.com/p-463090.html