《ASTM B444-2006(2011) Standard Specification for Nickel-Chromium-Molybdenum-Columbium Alloys (UNS N06625 and UNS N06852) and Nickel-Chromium-Molybdenum-Silicon Alloy (UNS N06219) Pi.pdf》由会员分享,可在线阅读,更多相关《ASTM B444-2006(2011) Standard Specification for Nickel-Chromium-Molybdenum-Columbium Alloys (UNS N06625 and UNS N06852) and Nickel-Chromium-Molybdenum-Silicon Alloy (UNS N06219) Pi.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B444 06 (Reapproved 2011)Standard Specification forNickel-Chromium-Molybdenum-Columbium Alloys(UNS N06625 and UNS N06852) and Nickel-Chromium-Molybdenum-Silicon Alloy (UNS N06219) Pipe and Tube1This standard is issued under the fixed designation B444; the number immediately following th
2、e designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for
3、use by agencies of the Department of Defense.1. Scope*1.1 This specification2covers nickel-chromium-molybdenum-columbium alloys (UNS N06625 and UNSN06852) and nickel-chromium-molybdenum-silicon alloy(UNS N06219)* in the form of cold-worked seamless pipe andtube. The general requirements for pipe and
4、 tube are coveredby Specification B829.1.1.1 UNS N06625 products are furnished in two grades ofdifferent heat-treated conditions:1.1.1.1 Grade 1 (annealed)Material is normally em-ployed in service temperatures up to 1100F (593C).1.1.1.2 Grade 2 (solution annealed)Material is normallyemployed in serv
5、ice temperatures above 1100F (593C) whenresistance to creep and rupture is required.NOTE 1Hot-working or reannealing may change properties signifi-cantly, depending on working history and temperatures.1.1.2 Alloys UNS N06219 and UNS N06852 are supplied inthe solution annealed condition only.1.2 The
6、values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 The following precautionary caveat pertains only to thetest methods portion, Section 9, o
7、f this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to become familiar with all hazards includingthose identified in the appropriate Material Safety Data Sheet(MSDS) for this p
8、roduct/material as provided by the manufac-turer, to establish appropriate safety and health practices, anddetermine the applicability of regulatory limitations prior touse.2. Referenced Documents2.1 ASTM Standards:3B829 Specification for General Requirements for Nickeland Nickel Alloys Seamless Pip
9、e and Tube3. General Requirement3.1 Material furnished under this specification shall con-form to the applicable requirements of Specification B829unless otherwise provided herein.4. Ordering Information4.1 Orders for material to this specification shall includeinformation with respect to the follow
10、ing:4.1.1 Alloy name or UNS number,4.1.2 ASTM designation,4.1.3 Condition (temper) (see 1.1.1, 1.1.2, Section 6, andAppendix X1 and Appendix X2),4.1.3.1 If neither grade of N06625 is specified, Grade 1 willbe supplied.4.1.4 Finish (See Appendix X2),4.1.5 Dimensions:4.1.5.1 TubeSpecify outside diamet
11、er and nominal orminimum wall,4.1.5.2 PipeSpecify standard pipe size and schedule,4.1.5.3 LengthCut to length or random,4.1.6 QuantityFeet (or metres) or number of pieces,4.1.7 Hydrostatic Test or Nondestructive Electric TestSpecify type of test (see 6.2),4.1.8 Hydrostatic Pressure RequirementsSpeci
12、fy testpressure if other than required by 9.1.1,1This specification is under the jurisdiction of ASTM Committee B02 onNonferrous Metals and Alloys and is the direct responsibility of SubcommitteeB02.07 on Refined Nickel and Cobalt and Their Alloys.Current edition approved May 1, 2011. Published May
13、2011. Originallyapproved in 1966. Last previous edition approved in 2006 as B444 06. DOI:10.1520/B0444-06R11.* New designation established in accordance with Practice E527 and SAEJ 1086, Practice for Numbering Metals and Alloys (UNS).2For ASME Boiler and Pressure Vessel Code applications see related
14、 Specifi-cation SB-444 in Section II of that Code.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary
15、 of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.9 CertificationState if certification is required,4.1.10 Samples for Product (Check) AnalysisStatewhether samples for product
16、(check) analysis should be fur-nished (see 5.2),4.1.11 Purchaser InspectionIf purchaser wishes to wit-ness tests or inspection of material at place of manufacture, thepurchase order must so state indicating which tests or inspec-tions are to be witnessed, and4.1.12 Small-Diameter and Light-Wall Tube
17、 (ConverterSizes)See Appendix X1 and Table 1.5. Chemical Composition5.1 The material shall conform to the composition limitsspecified in Table 2. One test is required for each lot as definedin Specification B829.5.2 If a product (check) analysis is performed by thepurchaser, the material shall confo
18、rm to the product (check)analysis variations in Table 2 of Specification B829.6. Mechanical Properties and Other Requirements6.1 Tension TestThe material shall conform to the tensileproperties specified in Table 1. The sampling and specimenpreparation are as covered in Specification B829.6.2 Hydrost
19、atic or Nondestructive Electric TestEach pipeor tube shall be subjected to either the hydrostatic test or to thenondestructive electric test. The type of test to be used shall beat the option of the manufacturer, unless otherwise specified inthe purchase order.7. Dimensions and Permissible Variation
20、s7.1 Permissible variations for material specified as small-diameter and light-wall tube (converter size) shall conform tothe permissible variations prescribed in Table X1.1 and TableX1.2.8. Number of Tests8.1 Chemical AnalysisOne test per lot.8.2 TensionOne test per lot.8.3 Hydrostatic or Nondestru
21、ctive Electric TestEachpiece in each lot.9. Test Methods9.1 Hydrostatic TestEach pipe or tube with an outsidediameter18 in. (3 mm) and larger and with wall thickness of0.015 in. (0.38 mm) and over shall be tested in accordance withSpecification B829. The allowable fiber stress for material inthe con
22、dition furnished, is as follows:UNS N06625:Grade 130 000 psi (207 MPa)Grade 225 000 psi (172 MPa)UNS N06219:All24 000 psi (165 MPa)UNS N06852:All21 000 psi (145 MPa)9.1.1 When so agreed upon by the manufacturer and pur-chaser, pipe or tube may be tested to 112 times the allowablefiber stress given a
23、bove.9.1.2 If any pipe or tube shows leak during hydrostatictesting, it shall be rejected.9.2 Nondestructive Electric TestEach pipe or tube shall beexamined with a nondestructive electric test as per prescribedin Specification B829.10. Keywords10.1 seamless pipe; seamless tube; N06219; N06625TABLE 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB44420062011STANDARDSPECIFICATIONFORNICKELCHROMIUMMOLYBDENUMCOLUMBIUMALLOYSUNSN06625ANDUNSN06852ANDNICKELCHROMIUMMOLYBDENUMSILICONALLOYUNSN06219PIPDF

链接地址:http://www.mydoc123.com/p-461252.html