ASTM B114-2007 Standard Test Method for Temperature-Resistance Constants of Sheet Materials for Shunts and Precision Resistors《分流器与精密电阻器用薄板材料温度-电阻常数的标准试验方法》.pdf
《ASTM B114-2007 Standard Test Method for Temperature-Resistance Constants of Sheet Materials for Shunts and Precision Resistors《分流器与精密电阻器用薄板材料温度-电阻常数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B114-2007 Standard Test Method for Temperature-Resistance Constants of Sheet Materials for Shunts and Precision Resistors《分流器与精密电阻器用薄板材料温度-电阻常数的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 114 07Standard Test Method forTemperature-Resistance Constants of Sheet Materials forShunts and Precision Resistors1This standard is issued under the fixed designation B 114; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the changeof resistance with temperature of sheet mat
3、erials used forshunts and precision resistors for electrical apparatus. It isapplicable to materials normally used in the temperature rangeof from 0 to 80C.1.2 The values stated in inch-pound units are to be regardedas the standard. The metric equivalents of inch-pound unitsmay be approximate.1.3 Th
4、is standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to become familiarwith all hazards including those identified in the appropriateMaterial Safety Data Sheet (MSDS) for this product/materialas provi
5、ded by the manufacturer, to establish appropriatesafety and health practices, and determine the applicability ofregulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B 84 Test Method for Temperature-Resistance Constants ofAlloy Wires for Precision Resistors3. Significance an
6、d Use3.1 This test method covers the determination of the changeof resistance with temperature for precision resistors andshunts made from sheet materials.3.2 Materials normally used in the temperature range from 0to 80C may be tested using this test method.4. Test Specimen4.1 The test specimen shal
7、l be of such dimensions that itselectrical resistance can be measured to the required accuracy.NOTE 1Measurements are simplified if the specimen has a resistanceof 0.01 V or more. The specimen may be bent in the form of a “U” tofacilitate handling.5. Terminals5.1 A current terminal shall be attached
8、 to each end of thespecimen. These terminals shall be either soldered or clampedin such a manner that there will be no change of currentdistribution in the specimen during the test.5.2 Potential terminals, one at each end, shall be located ata distance not less than two times the width of the specim
9、enfrom the current terminals. These terminals shall be attached atthe center of the width of the specimen either by soldering toears cut out of the specimen (Note 2) as shown in Fig. 1 or byclamps, each of which presses a single sharp point into thematerial.NOTE 2The ears shall be cut so that they a
10、re about12 in. (12.7 mm)in length and18 in. (3.2 mm) in width. The cut shall be clean and free fromslivers at the junction of the ear and the specimen. Before cutting the ears,it is desirable to drill two small holes with a sharp drill where the ear willbe jointed to the specimen.6. Preliminary Trea
11、tment for Manganin Samples6.1 In the case of manganin materials, after all the mechani-cal work has been finished, the specimen shall be given oneheat treatment of 48 h at 140 6 5.0C and then cooled to roomtemperature.6.2 The specimen shall then be given a dip in a nitric acidsolution (50 %) to remo
12、ve the copper film (which can bejudged by the color of the specimen) and then thoroughlyscrubbed in running water.7. Apparatus7.1 The apparatus for making the test shall consist of one ormore baths for maintaining the specimen at the desiredtemperature, thermometers for measuring the temperatures of
13、the baths, and suitable means for measuring the resistance ofthe specimen.8. Baths8.1 Each bath shall consist of chemically neutral oil. The oilshall be of such quantity and so well stirred that the tempera-ture in the region occupied by the specimen and the thermom-eter shall be uniform within 0.2C
14、 for any temperature between0 and 80C.1This test method is under the jurisdiction of ASTM Committee B02 onNonferrous Metals and Alloys and is the direct responsibility of SubcommitteeB02.10 on Thermostat Metals and Electrical Resistance Heating Materials.Current edition approved May 1, 2007. Publish
15、ed June 2007. Originallyapproved in 1938. Last previous edition approved in 2001 as B 114 90 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Do
16、cument Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8.2 In an automatically controlled bath, the temperature ofthe bath at any time during the test at any temperature levelshall not differ from its
17、mean temperature by more than 0.2C.In a manually controlled bath, the rate of change of tempera-ture shall not exceed 0.2C/min.9. Temperature Measurement9.1 The temperature shall be measured by a calibratedtemperature measuring device of suitable precision and accu-racy. The thermometer shall have s
18、ufficient sensitivity toindicate temperature changes of 0.1C. It shall be sufficientlyaccurate to measure temperature differences to 0.2C in therange from 0 to 80C.10. Resistance Measurements10.1 The change of resistance of the specimen shall bemeasured by apparatus capable of determining such chang
19、es to0.001 % of the resistance of the specimen. A Kelvin doublebridge, digital ohmmeter, or equivalent is suitable for thispurpose (see Appendix X1).10.2 The temperature of the measuring apparatus shall notchange during the test by an amount sufficient to introduceappreciable errors in the results.
20、With apparatus of goodquality, a change of 1C in its temperature is allowable.10.3 The test current shall not be of such a magnitude as toproduce an appreciable change in resistance of the specimen ormeasuring apparatus due to the heating effect. The dimensionsof the specimen should be such that the
21、 power dissipated shallnot exceed 0.02 W/in.2(0.003 W/cm2) of exposed surface. Todetermine experimentally that the test current is not too large,the specimen may be immersed in a bath having a temperatureat which it has been found that the sheet has a relatively largechange in resistance with temper
22、ature. The test current shall beapplied and maintained until the resistance of the specimen hasbecome constant. The current shall then be increased by 40 %and maintained at this value until the resistance has againbecome constant. If the change in resistance is greater than0.001 %, the test current
23、is too large and shall be reduced untilthe foregoing limitation is reached.10.4 The measurements shall be made in such a way that theeffects of thermoelectromotive forces and parasitic currents areavoided. When these effects are small, the resistance of thespecimen when measured by a Kelvin bridge m
24、ay be obtainedby either of two methods. In the first method, the galvanometerzero shall be obtained with the galvanometer key open. Thebridge shall be balanced both with the direct and reversedconnection of the battery, the average value of the two resultsbeing the resistance of the specimen. In the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB1142007STANDARDTESTMETHODFORTEMPERATURERESISTANCECONSTANTSOFSHEETMATERIALSFORSHUNTSANDPRECISIONRESISTORS

链接地址:http://www.mydoc123.com/p-460368.html