《ASTM A939-2007 Standard Practice for Ultrasonic Examination from Bored Surfaces of Cylindrical Forgings《圆柱体锻件钻孔表面的超声波检验用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A939-2007 Standard Practice for Ultrasonic Examination from Bored Surfaces of Cylindrical Forgings《圆柱体锻件钻孔表面的超声波检验用标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 939 07Standard Practice forUltrasonic Examination from Bored Surfaces of CylindricalForgings1This standard is issued under the fixed designation A 939; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers a basic procedure of ultrasonicallyinspecting cylindrical forgings with bores from the boresurface.
3、1.2 This practice applies to the manual testing mode. It doesnot restrict the use of other testing modes, such as mechanizedor automated.1.3 This practice applies to cylindrical forgings having boresizes equal to or greater than 2.5 in. (63.5 mm).1.4 The values stated in inch-pound units are to be r
4、egardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the u
5、ser of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Significance and Use2.1 This practice shall be used when ultrasonic inspectionfrom the bore surface is required by the order or specificationfor inspe
6、ction purposes in which the acceptance of the forgingis based on limitations of the number, amplitude, or location ofdiscontinuities or a combination thereof, which leads to ultra-sonic indications.2.2 The acceptance criteria shall be stated clearly as orderrequirements.2.3 This practice specifies d
7、ual search units, which depend-ing on the angle, are sensitive only to 2 to 3 in. into the metalfrom the bore surface.3. General Requirements3.1 As far as possible, the entire bore surface shall besubjected to ultrasonic inspection. It may be impossible toinspect some small portions of the bore surf
8、ace because ofchamfers at stepdowns and other local configurations.3.2 The bore ultrasonic inspection shall be performed afterthe final austenitizing and tempering heat treatment for me-chanical properties of the forging, and may be performed eitherprior to or after any subsequent stress relieving h
9、eat treatment.3.3 The ultrasonic beam shall be introduced radially foroverall scanning.3.4 Forgings may be tested either when stationary or whilerotated by means of a lathe or rollers.3.5 To ensure complete coverage of the bore surface, thesearch unit shall be indexed approximately 75 % of thetransd
10、ucer width with each pass of the search unit.3.6 A frequency of 214 MHz shall be used unless additionaltransducer frequencies are specified by the purchaser.3.7 The bore hole diameter and calibration hole(s) shall beas specified on the purchasers drawing or order.4. Pulsed Ultrasonic Reflection Equi
11、pment andAccessories4.1 Electronic ApparatusA pulse echo instrument permit-ting inspection frequencies of 1, 2.25, and 5 MHz is required.The accuracy of discontinuity amplitude analysis using thispractice involves a knowledge of the true operating frequencyof the complete inspection system. One of t
12、he best ways toobtain the desired accuracy is by use of a tuned pulser andnarrow band amplifier of known frequency response, witheither a broad band transducer or a narrow band tunedtransducer of known and matching frequency. An equipmentcalibration plan that is acceptable to both the purchaser and
13、thesupplier shall be available.4.2 AmplifierThe amplifier and the cathode ray tube shallprovide linear response (within 65%)upto112 in. (38.1 mm)sweep to peak.An equipment calibration plan that is acceptableto both the purchaser and the supplier shall be available.4.3 Signal AttenuatorThe instrument
14、 shall contain a cali-brated gain control or signal attenuator (accurate within 65%in each case) that will allow indications beyond the linear rangeof the instrument to be measured. It is recommended that thesecontrols permit signal adjustment up to 25 to 1 (28 dB).4.4 Search UnitsDual longitudinal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA9392007STANDARDPRACTICEFORULTRASONICEXAMINATIONFROMBOREDSURFACESOFCYLINDRICALFORGINGS 圆柱体 锻件 钻孔

链接地址:http://www.mydoc123.com/p-460032.html