ASTM A763-1993(2004) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels《铁素体不锈钢晶间腐蚀敏感性检测的标准操作规程》.pdf
《ASTM A763-1993(2004) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels《铁素体不锈钢晶间腐蚀敏感性检测的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A763-1993(2004) Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels《铁素体不锈钢晶间腐蚀敏感性检测的标准操作规程》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 763 93 (Reapproved 2004)Standard Practices forDetecting Susceptibility to Intergranular Attack in FerriticStainless Steels1This standard is issued under the fixed designation A 763; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These practices cover the following four tests:1.1.1 Practice WOxalic acid etch test for de
3、tecting sus-ceptibility to intergranular attack in stabilized ferritic stainlesssteels by classification of the etching structures (see Sections 3through 10).1.1.2 Practice XFerric sulfate-sulfuric acid test for detect-ing susceptibility to intergranular attack in ferritic stainlesssteels (Sections
4、11 to 16).1.1.3 Practice YCopper-copper sulfate-50 % sulfuric acidtest for detecting susceptibility to intergranular attack in ferriticstainless steels (Sections 17 to 22).1.1.4 Practice ZCopper-copper sulfate-16 % sulfuric acidtest for detecting susceptibility to intergranular attack in ferriticsta
5、inless steels (Sections 23 to 29).1.2 The following factors govern the application of thesepractices (16)2:1.2.1 Practice W, oxalic acid test, is a rapid method ofidentifying, by simple, electrolytic etching, those specimens ofcertain ferritic alloys that are not susceptible to intergranularcorrosio
6、n associated with chromium carbide precipitation.Practice W is used as a screening test to avoid the necessity, foracceptable specimens, of more extensive testing required byPractices X, Y, and Z. See Table 1 for a listing of alloys forwhich Practice W is appropriate.1.2.2 Practices X, Y, and Z can
7、be used to detect thesusceptibility of certain ferritic alloys to intergranular attackassociated with the precipitation of chromium carbides ornitrides.1.2.3 Practices W, X, Y, and Z can also be used to evaluatethe effect of heat treatment or of fusion welding on suscepti-bility to intergranular cor
8、rosion.1.2.4 Table 2 lists the identification ferritic stainless steelsfor which data on the application of at least one of the standardpractices is available.1.2.5 Some stabilized ferritic stainless steels may show highrates when tested by Practice X because of metallurgicalfactors not associated w
9、ith chromium carbide or nitride pre-cipitation. This possibility must be considered in selecting thetest method. Combinations of alloys and test methods forwhich successful experience is available are shown in Table 1.Application of these standard tests to the other ferritic stainlesssteels will be
10、by specific agreement between producer and user.1.3 Depending on the test and alloy, evaluations may beaccomplished by weight loss determination, microscopicalexamination, or bend test (Sections 30 and 31). The choices arelisted in Table 1.1.4 This standard does not purport to address all of thesafe
11、ty problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific safetyprecautionary statements, see 3.2.5, Section 7, 13.1, a
12、nd 19.1.2. Referenced Documents2.1 ASTM Standards:3A 370 Test Methods and Definitions for Mechanical Testingof Steel Products3. Apparatus3.1 Apparatus for Practice W, Oxalic Acid Etch Test:3.1.1 Source of DCBattery, generator, or rectifier capableof supplying 15 V and 20 A.3.1.2 Ammeter, range 0 to
13、30 A.3.1.3 Variable Resistance, for control of specimen current.3.1.4 CathodeOne-litre stainless steel beaker or suitablepiece of stainless steel.3.1.5 Electric Clamp, to hold etched specimen.3.1.6 Metallurgical Microscope, for examination of etchedstructures at 250 to 5003.3.1.7 ElectrodesThe speci
14、men is made the anode and thebeaker or other piece of stainless steel the cathode.3.1.8 ElectrolyteOxalic acid (H2C2O42H2O) reagentgrade, 10 weight % solution.1These practices are under the jurisdiction of ASTM Committee A01 on Steel,Stainless Steel and Related Alloys, and are the direct responsibil
15、ity of SubcommitteeA01.14 on Methods of Corrosion Testing.Current edition approved March 1, 2004. Published March 2004. Originallyapproved in 1979. Last previous edition approved in 1999 as A 763 93 (1999)e1.2The boldface numbers in parentheses refer to the list of references appended tothese practi
16、ces.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO
17、Box C700, West Conshohocken, PA 19428-2959, United States.3.2 The apparatus common to Practices X, Y, and Z is listedbelow. Supplementary requirements are noted as required.3.2.1 The apparatus used is shown in Fig. 1.NOTE 1No substitution for this equipment may be used. The cold-finger type of conde
18、nser with standard Erlenmeyer flasks may not be used.3.2.2 Allihn or Soxhlet Condenser, four-bulb (minimum)with a 45/50 ground-glass joint. Overall length shall be about330 mm (13 in.) with condensing section, 241 mm (912 in.).3.2.3 Erlenmeyer Flask, 1-L with a 45/50 ground-glassjoint. The ground-gl
19、ass opening is somewhat over 38 mm (112in.) wide.3.2.4 Glass Cradles (Note 2) can be supplied by a glassblowing shop. The size of the cradles should be such that theycan pass through the ground-glass joint of the Erlenmeyerflask. They should have three or four holes in them to increasecirculation of
20、 the test solution around the specimen.NOTE 2Other equivalent means of specimen support such as glasshooks or stirrups may also be used.3.2.5 Boiling Chips, must be used to prevent bumping. Ithas been reported that violent boiling resulting in acid spillscan occur. It is important to ensure that the
21、 concentration ofacid does not become more concentrated and that an adequatenumber of boiling chips (which are resistant to attack by thetest solution) are present.43.2.6 Silicone Grease, is recommended for the ground-glassjoint.3.2.7 Electrically Heated Hot Plate, or other device toprovide heat for
22、 continuous boiling of the solution.4Amphoteric alundum granules, Hengar Granules, from the Hengar Company,Philadelphia, PA have been found satisfactory for this purpose.TABLE 1 Methods for Evaluating Ferritic Stainless Steels for Susceptibility to Intergranular CorrosionAlloy Time of Test, hEvaluat
23、ion CriteriaWeight Loss MicroscopicalExaminationBend TestPRACTICE WOXALIC ACID ETCH TEST439 0.025 NA AANA18Cr-2Mo 0.025 NA AANAXM27 0.025 NA AANAXM33 0.025 NA AANA26-3-3 0.025 NA AANAPRACTICE XFERRIC SULFATE - SULFURIC ACID TEST430 24 AB,CANA446 72 ACXM27 120 ADACNA29Cr-4Mo 120 NAEACNA29Cr-4Mo-2Ni 1
24、20 NA ACNAPRACTICE YCOPPER-COPPER SULFATE - 50% SULFURIC ACID TEST446 96 ACANAXM27 120 ADACNAXM33 120 ADACNA2633 120 ADACNA29-4C 120 ADACNA29Cr-4Mo 120 NA ACNA29Cr-4Mo-2Ni 120 NA ACNAPRACTICE ZCOPPER-COPPER SULFATE - 16% SULFURIC ACID TEST430 24 NA NA no fissures434 24 NA NA no fissures436 24 NA NA
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA76319932004STANDARDPRACTICESFORDETECTINGSUSCEPTIBILITYTOINTERGRANULARATTACKINFERRITICSTAINLESSSTEELS

链接地址:http://www.mydoc123.com/p-459447.html