《ASTM A609 A609M-1991(2002) Standard Practice for Castings Carbon Low-Alloy and Martensitic Stainless Steel Ultrasonic Examination Thereof《关于超声波检验的低合金、碳和马氏体不锈钢铸件用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A609 A609M-1991(2002) Standard Practice for Castings Carbon Low-Alloy and Martensitic Stainless Steel Ultrasonic Examination Thereof《关于超声波检验的低合金、碳和马氏体不锈钢铸件用标准实施规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A 609/A 609M 91 (Reapproved 2002)Standard Practice forCastings, Carbon, Low-Alloy, and Martensitic StainlessSteel, Ultrasonic Examination Thereof1This standard is issued under the fixed designationA609/A609M; the number immediately following the designation indicates the yearof original
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defen
3、se.1. Scope1.1 This practice2covers the standards and procedures forthe pulse-echo ultrasonic examination of heat-treated carbon,low-alloy, and martensitic stainless steel castings by thelongitudinal-beam technique.1.2 This practice is to be used whenever the inquiry,contract, order, or specificatio
4、n states that castings are to besubjected to ultrasonic examination in accordance with Prac-tice A 609/A 609M.1.3 This practice contains two procedures for ultrasonicinspection of carbon, low-alloy, and martensitic stainless steelcastings; that is, Procedure A and Procedure B. Procedure A isthe orig
5、inal A 609/A 609M practice and requires calibrationusing a series of test blocks containing flat bottomed holes. Italso provides supplementary requirements for angle beamtesting. Procedure B requires calibration using a back wallreflection from a series of solid calibration blocks.NOTE 1Ultrasonic e
6、xamination and radiography are not directlycomparable. This examination technique is intended to complement GuideE94in the detection of discontinuities.1.4 The values stated in either inch-pound units or SI unitsare to be regarded separately as standard. Within the text, theSI units are shown in bra
7、ckets. The values stated in eachsystem are not exact equivalents; therefore, each system mustbe used independently of the other. Combining values from thetwo systems may result in nonconformance with this practice.1.5 This standard does not purport to address all of thesafety concerns, if any, assoc
8、iated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:A 217/A217M Specification for Steel Castings, MartensiticSt
9、ainless and Alloy, for Pressure-Containing Parts, Suit-able for High-Temperature Service3E94 Guide for Radiographic Examination4E 317 Practice for Evaluating Performance Characteristicsof Ultrasonic Pulse-Echo Examination Instruments andSystems Without the Use of Electronic MeasurementInstruments42.
10、2 Other Document:SNT-TC-1A Recommended Practice for Non-DestructiveTesting Personnel Qualification and Certification53. Ordering Information3.1 The inquiry and order should specify which procedure isto be used. If a procedure is not specified, ProcedureAshall beused.3.2 Procedure AFlat-Bottomed Hole
11、 Calibration Proce-dure:3.2.1 When this practice is to be applied to an inquiry,contract, or order, the purchaser shall furnish the followinginformation:3.2.1.1 Quality levels for the entire casting or portionsthereof,3.2.1.2 Sections of castings requiring longitudinal-beamexamination,3.2.1.3 Sectio
12、ns of castings requiring dual element exami-nation,3.2.1.4 Sections of castings requiring supplementary exami-nation, using the angle-beam procedure described in Supple-mentary Requirement S1 in order to achieve more completeexamination, and3.2.1.5 Any requirements additional to the provisions of th
13、ispractice.3.3 Procedure B: Back-Wall Reflection CalibrationProcedureWhen this procedure is to be applied to an inquiry,contract, or order, the purchaser shall designate the qualitylevels for the entire casting or applicable portions.1This practice is under the jurisdiction of ASTM Committee A01 on
14、Steel,Stainless Steel and Related Alloys and is the direct responsibility of SubcommitteeA01.18 on Castings.Current edition approved March 10, 2002. Published July 1992. Originallypublished as A 609 70. Last previous edition A 609/A 609M 90.2For ASME Boiler and Pressure Vessel Code applications, see
15、 related Specifi-cation SA-609 of Section II of that Code.3Annual Book of ASTM Standards, Vol 01.02.4Annual Book of ASTM Standards, Vol 03.03.5Available from American Society for Nondestructive Testing, P.O. Box 28518,1711 Arlingate Ln., Columbus, OH 43228-0518.1Copyright ASTM International, 100 Bar
16、r Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.PROCEDURE AFLAT-BOTTOMED HOLECALIBRATION PROCEDURE4. Apparatus4.1 Electronic Apparatus:4.1.1 An ultrasonic, pulsed, reflection type of instrumentthat is capable of generating, receiving, and amplifying fre-quencies of at le
17、ast 1 to 5 MHz.4.1.2 The ultrasonic instrument shall provide linear presen-tation (within 65 %) for at least 75 % of the screen height(sweep line to top of screen). Linearity shall be determined inaccordance with Practice E 317 or equivalent electronic means.4.1.3 The electronic apparatus shall cont
18、ain a signal attenu-ator or calibrated gain control that shall be accurate over itsuseful range to 610 % of the nominal attenuation or gain ratioto allow measurement of signals beyond the linear range of theinstrument.4.2 Search Units:4.2.1 Longitudinal Wave, internally grounded, havingato1! in. 13
19、to 28 mm diameter or 1-in. 25-mm squarepiezo-electric elements. Based on the signals-to-noise ratio ofthe response pattern of the casting, a frequency in the rangefrom 1 to 5 MHz shall be used. The background noise shall notexceed 25 % of the distance amplitude correction curve(DAC). Transducers sha
20、ll be utilized at their rated frequencies.4.2.2 Dual-Element, 5-MHz, by 1-in. 13 by 25-mm, 12included angle search units are recommended for sections 1 in.25 mm and under.4.2.3 Other frequencies and sizes of search units may beused for evaluating and pinpointing indications.4.3 Reference Blocks:4.3.
21、1 Reference blocks containing flat-bottom holes shall beused to establish test sensitivity in accordance with 8.2.4.3.2 Reference blocks shall be made from cast steels thatgive an acoustic response similar to the castings being exam-ined.4.3.3 The design of reference blocks shall be in accordancewit
22、h Fig. 1, and the basic set shall consist of those blocks listedin Table 1. When section thicknesses over 15 in. 380-mm areto be inspected, an additional block of the maximum testthickness shall be made to supplement the basic set.4.3.4 Machined blocks with332-in. 2.4-mm diameter flat-bottom holes a
23、t depths from the entry surface of18 in. 3 mm,12 in. 13 mm, or12 t and34 in. 19 mm, or34 t (where t =thickness of the block) shall be used to establish the DAC forthe dual-element search units (see Fig. 2).4.3.5 Each reference block shall be permanently identifiedalong the side of the block indicati
24、ng the material and the blockidentification.4.4 CouplantA suitable couplant having good wettingcharacteristics shall be used between the search unit andexamination surface. The same couplant shall be used forcalibrations and examinations.5. Personnel Requirements5.1 The manufacturer shall be respons
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA609A609M19912002STANDARDPRACTICEFORCASTINGSCARBONLOWALLOYANDMARTENSITICSTAINLESSSTEELULTRASONICEXAMINATIONTHEREOF

链接地址:http://www.mydoc123.com/p-458938.html