ASTM A598 A598M-2002(2015) Standard Test Method for Magnetic Properties of Magnetic Amplifier Cores《磁放大器芯磁性的标准试验方法》.pdf
《ASTM A598 A598M-2002(2015) Standard Test Method for Magnetic Properties of Magnetic Amplifier Cores《磁放大器芯磁性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM A598 A598M-2002(2015) Standard Test Method for Magnetic Properties of Magnetic Amplifier Cores《磁放大器芯磁性的标准试验方法》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A598/A598M 02 (Reapproved 2015)Standard Test Method forMagnetic Properties of Magnetic Amplifier Cores1This standard is issued under the fixed designation A598/A598M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the mag-netic performance of fully processed cores for magnetica
3、mplifier-type applications.1.2 Tests may be conducted at excitation frequencies of 60,400, 1600 Hz, or higher frequencies.1.3 Permissible core sizes for this test method are limitedonly by the available power supplies and the range andsensitivity of the instrumentation.1.4 At specified values of ful
4、l-wave sinusoidal-currentexcitation, Hmax, this test method provides procedures ofdetermining the corresponding value of maximum induction,Bmax.1.5 At specified values of half-wave sinusoidal-currentexcitation, this test method provides procedures for determin-ing the residual induction, Br.1.6 At i
5、ncreased specified values of half-wave sinusoidal-current excitation, this test method provides procedures fordetermining the dc reverse biasing magnetic field strength, H1,required to reset the induction in the core material past Brto avalue where the total induction change, B1, becomes approxi-mat
6、ely one third of the induction change, 2 Bp. It also providesprocedures for determining the additional dc reset magneticfield strength, H, which, combined with H1, is the valuerequired to reset the induction in the core material past Brto avalue where the total induction change, B2, becomes approxi-
7、mately two thirds of the induction change 2 Bp.1.7 This test method specifies procedures for determiningcore gain from the corresponding biasing and inductionchanges, H and B.1.8 This test method covers test procedures and require-ments for evaluation of finished cores which are to be used inmagneti
8、c-amplifier-type applications. It is not a test for basic-material magnetic properties.1.9 This test method shall be used in conjunction withPractice A34/A34M.1.10 Explanations of symbols and abbreviated definitionsappear in the text of this test method. The official symbols anddefinitions are liste
9、d in Terminology A340.1.11 The values and equations stated in customary (cgs-emuand inch-pound) or SI units are to be regarded separately asstandard. Within this test method, SI units are shown inbrackets. The values stated in each system may not be exactequivalents; therefore, each system shall be
10、used independentlyof the other. Combining values from the two systems mayresult in nonconformance with this test method.1.12 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-p
11、riate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A34/A34M Practice for Sampling and Procurement Testingof Magnetic MaterialsA340 Terminology of Symbols and Definitions Relating toMagnetic TestingA596/
12、A596M Test Method for Direct-Current MagneticProperties of Materials Using the Ballistic Method andRing Specimens3. Terminology3.1 DefinitionsBelow is a list of symbols and definitionsas used in this test method. The official list of symbols anddefinitions may be found in Terminology A340. (See Tabl
13、e 1where indicated).3.2 Symbols:1This test method is under the jurisdiction of ASTM Committee A06 onMagnetic Properties and is the direct responsibility of Subcommittee A06.01 on TestMethods.Current edition approved April 1, 2015. Published April 2015. Originallyapproved in 1969. Last previous editi
14、on approved in 2007 as A598/A598M02(2007). DOI: 10.1520/A0598_A0598M-02R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、 ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1A = cross-sectional area of test specimen corematerial, cm2m2.A1= ac ammeter for primary circuit, half-wave,average-responsive, A.A2= dc ammeter for H1biasing winding, A.A3
16、= dc ammeter for H2biasing winding, A.A4= dc milliammeter for ac voltage calibrator, V.BmaxBr= change in test specimen induction, under half-wave sinusoidal-current excitation specifiedfor this measurement.Bm= maximum induction in a sine-current SCM acflux-current loop Gauss Tesla (Note 1).Bp= maxim
17、um value of induction in the sine-current half-wave CM flux-current loop, for thereset test Gauss Tesla (Note 1).Br= residual induction in an ac sine-current flux-current loop Gauss Tesla.B = change in magnetic induction Gauss Tesla(Table 1).B1= change in induction in the flux-current loopduring H1t
18、est Gauss Tesla (Table 1).B2= change of induction in the flux current loopduring H2test Gauss Tesla (Table 1).CM = cyclic magnetization (see Terminology A340).D1and D2= solid state diodes or other rectifiers.D3to D6= silicon diodes.d = lamination thickness, cm m.Eavg= average value of voltage wavefo
19、rm, V.f = frequency of test, Hz.G = core gain B2 B1/H2,H1,GaussOeFTA/mG.Hc= coercive field strength in an SCM flux-currentloop Oe A/m.Hmax= maximum magnetic field strength in a sine-current SCM ac flux-current loop, Oe A/m(Note 1).Hp= maximum value of the sine-current ac mag-netic field strength for
20、 the CM reset tests, OeA/m (Note 1).H1= dc biasing (reset) magnetic field strength forthe H1test point, Oe A/m.H2= dc biasing (reset) magnetic field strength forthe H2test point, Oe A/m.H = change in dc biasing (reset) magnetic fieldstrength, Oe A/m.N1= test winding primary, ac excitation winding,tu
21、rns.N2= test winding primary, dc H1biasing winding,turns.N3= test winding primary, dc H2biasing winding,turns.N4= test winding secondary, B pickup winding,turns.SCM = symmetrical cyclic magnetization (see Termi-nology A340).NOTE 1Note that Hmaxand Bmax, as used in this test method, aremaximum points
22、 on the sine-current SCM or corresponding half-waveCM flux-current loops.Also, that Hpand Bpare maximum points on a CMflux-current loop corresponding to the ac half-wave sine current which isestablished in the exciting winding, N1, and held constant, during the dccurrent measurements for H1, H2,orH.
23、 These definitions are differentfrom those used for the same symbols in Terminology A340 for use withdc or sinusoidal-flux ac measurements.4. Summary of Test Method4.1 This test method uses the procedures commonly referredto as the “Constant Current Flux Reset Test Method”(C.C.F.R.). For graphic rep
24、resentation of the magnetic ampli-fier core test see Appendix X3.4.2 Under its provision, a specific predetermined value ofsinusoidal-current excitation, Hmax,(Table 2) is established andthe corresponding induction change is measured to determinethe value of maximum induction which is then designate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA598A598M20022015STANDARDTESTMETHODFORMAGNETICPROPERTIESOFMAGNETICAMPLIFIERCORES 放大器 磁性 标准 试验 方法

链接地址:http://www.mydoc123.com/p-458892.html