ASSE 1002-2008 Performance Requirements for nAnti-Siphon Fill nValves for Water nCloset Tanks.pdf
《ASSE 1002-2008 Performance Requirements for nAnti-Siphon Fill nValves for Water nCloset Tanks.pdf》由会员分享,可在线阅读,更多相关《ASSE 1002-2008 Performance Requirements for nAnti-Siphon Fill nValves for Water nCloset Tanks.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、Performance Requirements forAnti-Siphon FillValves for WaterCloset TanksAmerican Society of Sanitary EngineeringASSE Standard #1002-2008ASSE Board Approved: APRIL 28, 2008ANSI Approval: DATEAn American National StandardCopyright American Society of Sanitary Engineering Provided by IHS under license
2、with ASSE Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright American Society of Sanitary Engineering Provided by IHS under license with ASSE Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-American Society of Sanitary Engi
3、neeringWestlake, OhioCopyright 2008, 1999, 1986, 1979, 1976Neither this standard, nor any portion thereof, may be reproduced without the written consentof the American Society of Sanitary Engineering.No product may be said to be ASSE approved unless the manufacturer has applied to theASSE, has had h
4、is product tested according to the applicable ASSE Standards, and when theproduct has passed the test, displays the ASSE Seal on the product.Instructions for receiving the authorization to display the Seal are available from ASSEsInternational Office. Organizations wishing to adopt or list any ASSE
5、Standard should print theASSE Standard number on the cover page first and in equal or larger type to that of the adoptingor listing organization.General InformationAnti-Siphon Fill Valves for Water Closet Tanks iASSE Standard #1002- 2008Copyright American Society of Sanitary Engineering Provided by
6、IHS under license with ASSE Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-ii Anti-Siphon Fill Valves for Water Closet TanksASSE Standard #1002 - 2008Copyright American Society of Sanitary Engineering Provided by IHS under license with ASSE Not for ResaleNo reprod
7、uction or networking permitted without license from IHS-,-,-This foreword shall not be considered a part of the standard, however, it is offered to providebackground information.ASSE standards are developed in the interest of consumer safety.This standard outlines the performance requirements for An
8、ti-siphon Fill Valves (Ballcocks) forGravity Water Closet Flush Tanks, and describes those performance requirements in terms ofmethods of testing applicable to all such units, equivalent materials or methods of testingintended to demonstrate compliance with these requirements are also acceptable.Rec
9、ognition is made of the time volunteered by members of the working group and of thesupport of the manufacturers who also participated in the meetings for this standard.This standard does not imply ASSEs endorsement of a product which conforms to theserequirements.Compliance with this standard does n
10、ot imply acceptance by any code body.It is recommended that these devices be installed consistent with local codes by qualified andtrained professionals.This standard was promulgated in accordance with procedures developed by the AmericanNational Standards Institute (ANSI).ForewordAnti-Siphon Fill V
11、alves for Water Closet Tanks iiiASSE Standard #1002 - 2008Copyright American Society of Sanitary Engineering Provided by IHS under license with ASSE Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Edward LyczkoProduct Standards Committee ChairmanCleveland ClinicCle
12、veland, OhioRand H. AckroydRand EngineeringNewburyport, MassachusettsGunnar O. CollinsCollins Backflow Specialists, Inc.Palatine, IllinoisJudson W. CollinsJULYCO ProfessionalsMannford, OklahomaShannon M. CorcoranASSE Standards CoordinatorWestlake, OhioA. Richard EmmersonGeneral InterestBuffalo Grove
13、, IllinoisRon GeorgeRon George Design and to ensure that the manufacturer has provided a means for securing the refill tubeto the overflow tube and that it remains in place during the test.3.1.2 ProcedureThe device shall be installed in a water closet tank or container per the manufacturers instruct
14、ions.The water shall be permitted to be displaced in the water closet tank or container. The water supplytemperature for this test shall be maintained at 120.0 F 5.0 F (48.9 C 2.8 C), with a staticpressure of 125.0 psi (861.9 kPa).Flush the water closet tank every five (5) minutes for a total of fif
15、ty (50) cycles using a flush volumetolerance of 1.4 to 2.0 gallons (5.3 to 7.6 liters).Following this test, and with the water closet tank filled with water maintained at 120.0 F 5.0 F(48.9 C 2.8 C), the pressure in the device shall be raised to 150.0 psig (1034.3 kPa) andmaintained for five (5) min
16、utes. The device shall be checked for leakage, distortion, or otherindications of damage which would affect the devices performance.3.1.3 CriteriaAny indications of leakage, distortion, or other damage which affects the devices performanceshall result in a rejection of the device. Failure of the ref
17、ill tube to remain in place throughout thistest shall result in a rejection of the device.3.2 Cycle Test3.2.1 PurposeThe purpose of this test is to demonstrate the devices long-term operational performance.3.2.2 ProcedureInstall the device per the manufacturers instructions in a water closet tank or
18、 container. The deviceshall be operated a total of seventy-five thousand (75,000) cycles at a minimum of 90.0 psi (620.6kPa) static pressure and 70.0 psig (482.7 kPa) minimum flowing pressure using ambienttemperature 65.0 F - 80.0 F (18.3 C to 26.7 C) water. For each cycle, the tank shall be filleda
19、nd the cycle shall have a maximum cycle time of one (1) minute. The water shall be permittedto be displaced in the tank to accelerate this test. Following this test, maintain a static pressureof 125.0 psig ( 861.9 kPa) for five (5) minutes, and observe for leakage, distortion, or otherindications of
20、 damage which would affect the devices performance.3.2.3 CriteriaAny indications of leakage, distortion, or other damage which affects the devices performanceshall result in a rejection of the device. Failure of the refill tube to remain in place throughout thistest shall result in a rejection of th
21、e device.4 Anti-Siphon Fill Valves for Water Closet TanksASSE Standard #1002 - 2008Copyright American Society of Sanitary Engineering Provided by IHS under license with ASSE Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.3 Critical Level Marking and Backflow Pre
22、vention Test3.3.1 PurposeThe purpose of this test is to verify the Critical Level (CL) marking, and ensure that the backflowprevention feature functions as intended.3.3.2 ProcedureInstall the device in accordance with Figure 2. Foul all of the check valves, seats and checkingmembers with a 0.032 inc
23、hes (0.8 mm) diameter wire. The fouling wire shall be placed at a singlepoint on each seating area.Figure 2Anti-Siphon Fill Valve Test AssemblyA sight glass shall be assembled to the shank assembly as shown in Figure 2. Start with the tankwater level 0.125 inches (3.2 mm) below the vacuum breaker ai
24、r port(s) or water dischargeopenings (air gaps type). As the water level is lowered, the device shall be subjected to aninstantaneous vacuum of 25 inches of mercury (84.7 kPa) until there is no water in the sight glass.Next, apply an intermittent vacuum of 5 inches of mercury (16.9 kPa) for five (5)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASSE10022008PERFORMANCEREQUIREMENTSFORNANTISIPHONFILLNVALVESFORWATERNCLOSETTANKSPDF

链接地址:http://www.mydoc123.com/p-457113.html