ARMY UFGS-10 14 00 20-2012 INTERIOR SIGNAGE.pdf
《ARMY UFGS-10 14 00 20-2012 INTERIOR SIGNAGE.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-10 14 00 20-2012 INTERIOR SIGNAGE.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-10 14 00.20 (November 2012)-Preparing Activity: USACE Superseding without RevisionUFGS-10 14 02 (February 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2012*SECTION TABLE OF CONTENTSDIVISION 10 - SPECIALTIESSECTIO
2、N 10 14 00.20INTERIOR SIGNAGE11/12PART 1 GENERAL1.1 REFERENCES1.2 SUSTAINABILITY REQUIREMENTS1.2.1 LEED Requirements1.2.2 EPA Comprehensive Procurement Guidelines1.3 SUBMITTALS1.4 EXTRA MATERIALS1.5 QUALITY ASSURANCE1.5.1 Samples1.5.2 Detail Drawings1.6 DELIVERY, STORAGE, AND HANDLING1.7 WARRANTYPAR
3、T 2 PRODUCTS2.1 STANDARD PRODUCTS2.2 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM2.2.1 Standard Room Signs2.2.2 Changeable Message Strip Signs2.2.3 Type of Mounting For Signs2.2.4 Graphics2.2.5 Character Proportions and Heights2.2.6 Tactile Letters, Symbols and Braille2.3 STAIR SIGNAGE2.4 BUILDING
4、 DIRECTORIES2.4.1 Header Panel2.4.2 Doors2.4.2.1 Door Glazing2.4.2.2 Door Construction2.4.2.3 Door Locks2.4.3 Fabrication2.4.4 Illuminated Units2.4.4.1 Construction2.4.4.2 Message Strips2.4.5 Non-Illuminated UnitSECTION 10 14 00.20 Page 1Provided by IHSNot for ResaleNo reproduction or networking per
5、mitted without license from IHS-,-,-2.4.5.1 Construction2.4.5.2 Message Strips2.4.6 Electronic Directory System2.5 METAL PLAQUES2.5.1 Cast Metal Plaques2.5.1.1 Fabrication2.5.1.2 Border2.5.1.3 Finish2.5.1.4 Mounting2.5.2 Chemically Etched Metal Plaques2.5.2.1 Fabrication2.5.2.2 Finish2.6 DIMENSIONAL
6、 BUILDING LETTERS2.6.1 Fabrication2.6.2 Size2.6.3 Finish2.6.4 Mounting2.7 PRESSURE SENSITIVE LETTERS2.7.1 Fabrication2.7.2 Size2.8 ALUMINUM ALLOY PRODUCTS2.9 ANODIC COATING2.10 ORGANIC COATING2.11 FABRICATION AND MANUFACTURE2.11.1 Factory Workmanship2.11.2 Dissimilar Materials2.12 COLOR, FINISH, AND
7、 CONTRAST2.13 TYPEFACEPART 3 EXECUTION3.1 INSTALLATION3.1.1 Anchorage3.1.2 Protection and Cleaning- End of Section Table of Contents -SECTION 10 14 00.20 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-10 14
8、 00.20 (November 2012)-Preparing Activity: USACE Superseding without RevisionUFGS-10 14 02 (February 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2012*SECTION 10 14 00.20INTERIOR SIGNAGE11/12*NOTE: This guide specification covers the requirements fo
9、r common types of signs, dimensional letters, and metal plaques used inside buildings.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project
10、 specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes fo
11、r this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: This section covers some of the more common interior sign types. When other sign types are to be used, such as elevator-related signs, occupancy load signs and structural load limi
12、t signs, specifications will be modified accordingly. Buildings will be accessible in accordance with 36 CFR, Part 1191, Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities except for Army buildings excluded by TI 800-01 Design Criteria.Reference UFC 3-120-01
13、available at http:/www.wbdg.org/ccb/DOD/UFC/ufc 3 120 01.pdfhttp:/www.wbdg.org/ccb/DOD/UFC/ufc 3 120 01.pdf Unified Federal Criteria Sign Standard for SECTION 10 14 00.20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-design, construction and
14、placement of signs. Defer to the most current version of ADA for Chapter 3 and throughout the UFC because the UFC has not been updated to include the most recent ADA revisions.In combination with this specification, drawings and attachments will include location, dimensions, elevations, schedules, c
15、ontent, details and such other information as required to indicate the extent of the work. The same terminology and designations used in the specification will be used on the drawings, schedules and attachments.Product selections shall be based on quality, aesthetic values, appearance, and cost as r
16、elated to project needs.Use of personal names on interior signage is discouraged. If personal names are required, changeable message strips will be used. Consider coordination of interior signage within this specification with signage required on individual workstations which is specified in Section
17、 12 50 00 FURNITURE SYSTEMS.Interior stairwell signage will be provided in accordance with Life Safety Code NFPA 101, Chapter 5, and applicable occupancy chapters. Clearly define interstitial spaces or other doorways within stairwell that do not lead to a horizontal exitway with signage that states
18、“Not an Exit“.Permanent information on room identification signs includes the room number on all room identification signs, symbol and message on toilet rooms, message on janitor closets, mechanical/electrical and communications rooms, and message on stairs.Where appropriate for MEDICAL FACILITIES,
19、include the following requirements for signage:1. Room numbering for spaces within the medical facility will be determined jointly by the using facility and the design team. User room number will be different than architectural room number (see MIL-HDBK 1191, 4.15.3). Room numbering will be consiste
20、nt throughout the facility. For inpatient medical facilities, rooms with audiovisual nurse call shall have a unique user room number, since audiovisual nurse call is tied into a digital paging system. For outpatient clinics, rooms with tonevisual nurse call, do not need a unique user room number, si
21、nce tonevisual nurse call is hardwired to a panel located at a nursing station. Room numbering should address the following issues:a. Wayfinding within clinics and other departments (user room #).SECTION 10 14 00.20 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without l
22、icense from IHS-,-,-b. Facility Maintenance (architectural room #).c. Audiovisual Nurse Call (inpatient) (unique user room #).d. Tonevisual Nurse Call (outpatient) (user room #).2. The use of symbols/graphics on interior signage will be limited. International symbols and graphics will be used where
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS101400202012INTERIORSIGNAGEPDF