ANSI UL 875-2009 UL Standard for Safety Electric Dry-Bath Heaters (Ninth Edition Reprint with Revisions Through and Including September 20 2017)《浴室电干燥加热器的安全性标准》.pdf
《ANSI UL 875-2009 UL Standard for Safety Electric Dry-Bath Heaters (Ninth Edition Reprint with Revisions Through and Including September 20 2017)《浴室电干燥加热器的安全性标准》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 875-2009 UL Standard for Safety Electric Dry-Bath Heaters (Ninth Edition Reprint with Revisions Through and Including September 20 2017)《浴室电干燥加热器的安全性标准》.pdf(119页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 875 Electric Dry-Bath Heaters STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORI
2、ZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Electric Dry-Bath Heaters, UL 875 Ninth Edition, Dated May 21, 2009 Summary of Topics This revision to ANSI/UL 875 is being issued to update requirements for coin cell batteries. The revised requiremen
3、ts are substantially in accordance with Proposal(s) on this subject dated August 4, 2017. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, stored
4、in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties
5、 of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL o
6、r an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemn
7、ify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. SEPTEMBER 20, 2017 UL 875 tr
8、1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 20, 2017 UL 875 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 21, 2009 (Title Page Reprinted:
9、 September 20, 2017) 1 UL 875 Standard for Electric Dry-Bath Heaters Prior to the rst edition, the requirements for the products covered by this standard were included in the Standard for Electric Heating Appliances, UL 499. The First through Third editions were titled Electric Dry Bath Heaters. The
10、 Fourth Edition was titled Electric Sauna Heating Equipment. First Edition August, 1970 Second Edition February, 1972 Third Edition June, 1976 Fourth Edition February, 1983 Fifth Edition August, 1989 Sixth Edition August, 1994 Seventh Edition September, 2000 Eighth Edition March, 2004 Ninth Edition
11、May 21, 2009 This ANSI/UL Standard for Safety consists of the Ninth Edition including revisions through September 20, 2017. The most recent designation of ANSI/UL 875 as an American National Standard (ANSI) occurred on September 20, 2017. ANSI approval for a standard does not include the Cover Page,
12、 Transmittal Pages, and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyr
13、ighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 875-2017
14、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 20, 2017 ELECTRIC DRY-BATH HEATERS - UL 875 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS I
15、NTRODUCTION 1 Scope .5 2 General 6 2.1 Components .6 2.2 Units of measurement .6 2.3 Undated references .6 3 Glossary .6 CONSTRUCTION 3A Component Specications 7 3B Component Specications 7 3B.1 General 7 3B.2 Button or coin cell batteries of lithium technologies 8 3C Safety Critical Functions 8A 4
16、Frame and Enclosure 8B 5 Risk of Injury to Persons 16A 5A Button or Coin Cell Batteries of Lithium Technologies .16B 6 Assembly 16B 7 Corrosion Resistance .17 8 Supply Connections 18 8.1 General 18 8.2 Field-wiring compartment .18 8.3 Wire-bending space .20 8.4 Field-wiring terminals and leads .21 9
17、 Current-Carrying Parts 23 10 Internal Wiring 23 10.1 General .23 10.2 Sleeving and tubing 24 10.3 Protection of wiring .24 10.4 Splices and connections .24A 10.5 Separation of circuits .25 10.6 Barrier material and thickness .27 10.7 Low-voltage circuits .27 10.8 Line-voltage circuits 28 11 Heating
18、 Elements .28 11.1 General .28 11.2 Sheathed heating element .28 11.3 Guarding of heating elements 28 12 Electrical Insulation .29 13 Thermal Insulation .30A 14 Motors .30A 15 Overcurrent Protection .30B 16 Motor-Running Overcurrent Protection .30B 16A Ground-Fault, Arc-Fault, and Leakage Current De
19、tectors / Interrupters .30C 16B Fuses and Circuit Breakers .30C 17 Short-Circuit Protection 30D 17A Light Sources and Associated Components .31 18 Lampholders .32 SEPTEMBER 20, 2017 ELECTRIC DRY-BATH HEATERS - UL 875 2AUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION W
20、ITHOUT PERMISSION FROM UL 19 Switches .32 20 Receptacles 33 20A Printed Wiring Boards 33 20B Semiconductors and Small Electronic Components 33 21 Automatic Temperature Controls 34 21.1 General .34 21.2 Terminals and actuating members of temperature controls 36 21A Liquid Level Controls 36 21B Pressu
21、re Controls .36 22 Spacings 36 22.1 General .36 22.2 Barriers .38 22A Clearance and Creepage Distances .38A 23 Grounding and Bonding .39 PERFORMANCE 24 Power Input Test .40 25 Temperature Test .40 26 Minimum Room Air Temperature Test .48 27 Insulation Resistance Test .48 28 Dielectric Voltage-Withst
22、and Test .48 29 Water Spray Test .49 30 Abnormal Operation Test 52 30.1 Temperature .52 30.2 Mechanical abuse 52 30.3 Cheesecloth and towel drape 54 30.4 Thermal cutoff 54A 30.5 Stalled fan .54A 30.6 Component breakdown 54A 31 Motor Switch Overload Test 54B 32 Stability Test 54B 33 Static Loading Te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL8752009ULSTANDARDFORSAFETYELECTRICDRYBATHHEATERSNINTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGSEPTEMBER202017

链接地址:http://www.mydoc123.com/p-439573.html