ANSI P1073.1.3.10 D3.0-1999 Draft Standard for Medical Device Communications - Medical Device Data Language (MDDL) Virtual Medical Device Specialized – Cardiac Output《医疗装置通信用标准草案.专用虚拟医疗.pdf
《ANSI P1073.1.3.10 D3.0-1999 Draft Standard for Medical Device Communications - Medical Device Data Language (MDDL) Virtual Medical Device Specialized – Cardiac Output《医疗装置通信用标准草案.专用虚拟医疗.pdf》由会员分享,可在线阅读,更多相关《ANSI P1073.1.3.10 D3.0-1999 Draft Standard for Medical Device Communications - Medical Device Data Language (MDDL) Virtual Medical Device Specialized – Cardiac Output《医疗装置通信用标准草案.专用虚拟医疗.pdf(49页珍藏版)》请在麦多课文档分享上搜索。
1、NOTICETHIS DOCUMENT IS AN UNAPPROVED IEEE STANDARDSDRAFT, SUBJECT TO CHANGE. THE IEEE SHALL NOT BELIABLE FOR ANY DAMAGES RESULTING FROM YOUR USEOF THIS UNAPPROVED IEEE STANDARDS DRAFT.The IEEE makes no guaranties or warranties as to the results to be obtainedfrom purchasing and using this unapproved
2、 IEEE Standards Draft documentin electronic form and is not responsible for problems in the delivery of thisdocument that are beyond its control. This IEEE Standards Draft, in pdf fileformat, is licensed solely for your personal use subject to the TERMS OFUSE.For more information about current, revi
3、sed, and withdrawn IEEEStandards, please consult the IEEE Standards Status Report on-line athttp:/standards.ieee.org/db/status/. For more information about unapprovedIEEE Standards Drafts that are available for purchase, please refer to ourcatalog listing at http:/standards.ieee.org/catalog/drafts.h
4、tml.Copyright The Institute of Electrical and Electronics Engineers, Inc. Provided by IHS under license with IEEENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-IEEE P1073.1.3.10 / D3.0Draft Standard forMedical Device Communications -Medical Device Data Language (M
5、DDL)Virtual Medical Device, Specialized Cardiac OutputPrepared byVital Signs Monitoring Working Group of the IEEE 1073 CommitteeSponsor:Engineering in Medicine and Biology Society (EMBS)Abstract: This standard establishes a model for the implementation of the Cardiac OutputVirtual Medical Device. It
6、 establishes a Design Model and specifies how this Model should beimplemented. It also provides guidance concerning bandwidth requirements as well as how tospecify conformance with this standard.Keywords: bedside, VMD, Channel, medical device, medical device communications, MIB,patient, Blood Temper
7、ature, Cardiac Output, Temperature, Injectate TemperatureNOTE: This draft is for review only and should not be distributed without permission of theeditor.Copyright 1999 by the Institute of Electrical and Electronics Engineers, Inc.345 East 47th StreetNew York, NY 10017, USAAll Rights Reserved.This
8、is an unapproved draft of a proposed IEEE Standard, subject to change. Permission is hereby granted for IEEEStandards Committee participants to reproduce this document for purposes of IEEE standardization activities. If thisdocument is to be submitted to ISO or IEC, notification shall be given to th
9、e IEEE Copyright Administrator.Permission is also granted for member bodies and technical committees of ISO and IEC to reproduce this documentfor purposes of developing a national position. Other entities seeking permission to reproduce portions of thisdocument for these or other uses must contact t
10、he IEEE Standards Department for the appropriate license. Use ofinformation contained in this unapproved draft is at your own risk.IEEE Standards DepartmentCopyright and Permissions445 Hoes Lane, P.O. Box 1331Piscataway, NJ 08855-1331, USACopyright The Institute of Electrical and Electronics Enginee
11、rs, Inc. Provided by IHS under license with IEEENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UNAPPROVED DRAFT PUBLISHED FOR COMMENT ONLYDraft 3 - P1073.1.3.10 Medical Device Communications, Cardiac OutputCopyright 1999 IEEE. All Rights Reserved.This is an unappr
12、oved IEEE Standards Draft, subject to change.2IntroductionThis is a draft copy of the IEEE 1073 Cardiac Output VMD Standard. The information and datapresented here is intended to provide a foundation on which the final document can be built.The subcommittee currently working on the development of th
13、is standard consists of:Ken Fuchs, ChairDan Nowicki GE Marquette Medical SystemsJan Wittenber AgilentWard Silver Medtronic Physio-ControlKen Fuchs Siemens Medical SystemsDennis Harding SpacelabsKen Hall SpacelabsTodd Cooper RealsoftPop Tufty Protocol SystemsJohn Villaire Protocol SystemsRick Schrenk
14、er Massachusetts General HospitalSpecial thanks to Kai Hassing of Agilent, Boeblingen Germany for his input into this document.All parts of this document are subject to further discussion and may be changed significantly inthe future as the associated IEEE 1073 upper layer documents are revised, and
15、 new upper layerdocuments are generated.Review and Feedback on the content of this is document is solicited and should be addressed tothe Editor:Ken FuchsSiemens Medical Systems16 Electronics Ave.,Danvers, MA 01923Phone: 978/907-7686Fax: 978/774-8342Email: ken.fuchsieee.orgCopyright The Institute of
16、 Electrical and Electronics Engineers, Inc. Provided by IHS under license with IEEENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UNAPPROVED DRAFT PUBLISHED FOR COMMENT ONLYDraft 3 - P1073.1.3.10 Medical Device Communications, Cardiac OutputCopyright 1999 IEEE. Al
17、l Rights Reserved.This is an unapproved IEEE Standards Draft, subject to change.3Revision HistoryRevisionNumberDate RemarksDraft 1 March 15, 1999 Initial Draft FormatDraft 2 May 5, 1999 Incorporate feedback from Toronto meetingDraft 3 October 31, 1999 Incorporate feedback from Vital Signs Meeting.Co
18、pyright The Institute of Electrical and Electronics Engineers, Inc. Provided by IHS under license with IEEENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UNAPPROVED DRAFT PUBLISHED FOR COMMENT ONLYDraft 3 - P1073.1.3.10 Medical Device Communications, Cardiac Outpu
19、tCopyright 1999 IEEE. All Rights Reserved.This is an unapproved IEEE Standards Draft, subject to change.4Table of Contents1 GENERAL .71.1 SCOPE71.2 PURPOSE 71.3 APPLICABILITY.81.4 AUDIENCE .81.5 ORGANIZATION.81.6 CONVENTIONS82 NORMATIVE REFERENCES93 DEFINITIONS 104 ABBREVIATIONS105 GENERAL VMD DOMAI
20、N INFORMATION MODEL .115.1 MEDICAL SUBJECT MODEL .115.2 APPLICATION PROFILES AND THE GENERAL VMD116 CARDIAC OUTPUT VMD DOMAIN INFORMATION MODEL136.1 GENERAL OVERVIEW .136.2 EXTENDING THE CARDIAC OUTPUT VMD136.3 CARDIAC OUTPUT VMD DOMAIN INFORMATION MODEL 136.4 VMO ATTRIBUTES156.4.1 Type156.4.2 Label
21、 String.156.5 VMD ATTRIBUTES166.5.1 VMD Status .166.5.2 VMD-Model166.5.3 Instance Number .166.5.4 Product Specification.166.5.5 Compatibility ID166.5.6 Parameter Group.176.5.7 Position .176.5.8 Operating Hours 176.5.9 Operating Cycles .176.5.10 Measurement Principle.177 INTERMITTENT CARDIAC OUTPUT C
22、HANNEL.18Copyright The Institute of Electrical and Electronics Engineers, Inc. Provided by IHS under license with IEEENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UNAPPROVED DRAFT PUBLISHED FOR COMMENT ONLYDraft 3 - P1073.1.3.10 Medical Device Communications, Ca
23、rdiac OutputCopyright 1999 IEEE. All Rights Reserved.This is an unapproved IEEE Standards Draft, subject to change.57.1 INTERMITTENT CARDIAC OUTPUT - CHANNEL ATTRIBUTES.187.1.1 Channel Status187.1.2 Measurement Principle.187.2 INTERMITTENT CARDIAC OUTPUT - METRIC ATTRIBUTES.197.2.1 Metric Specificat
24、ion197.2.2 Metric Status197.3 INTERMITTENT CARDIAC OUTPUT NUMERIC ATTRIBUTES217.3.1 Observed Value.217.3.2 Summary Intermittent Cardiac Output Numeric 227.4 INJECTATE TEMPERATURE NUMERIC ATTRIBUTES .237.4.1 Observed Value.237.4.2 Summary Injectate Temperature Numeric247.5 BLOOD TEMPERATURE NUMERIC A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIP10731310D301999DRAFTSTANDARDFORMEDICALDEVICECOMMUNICATIONSMEDICALDEVICEDATALANGUAGEMDDLVIRTUALMEDICALDEVICESPECIALIZED

链接地址:http://www.mydoc123.com/p-437839.html