1、Designation: E2026 16a An American National StandardStandard Guide forSeismic Risk Assessment of Buildings1This standard is issued under the fixed designation E2026; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONLenders, insurers, and equity owners in real estate are giving more intense scrutiny to earthquakerisk than ever before. Th
3、e 1989 Loma Prieta, California earthquake, which caused more than $6 billionin damage, accelerated the trend toward considering loss estimation in real estate transactions. The1994 Northridge, California earthquake, with over $20 billion in damage, made seismic riskassessment an integral part of rea
4、l estate financial decision-making for regions at risk of damagingearthquakes. Users of Seismic Risk Assessment reports need specific and consistent measures forassessing the possibility of future loss due to earthquake occurrences. This guide discusses specificapproaches that the real estate and te
5、chnical communities can consider a basis for characterizing theseismic risk assessment of buildings in an earthquake. It uses two concepts to characterize earthquakeloss: probable loss (PL) and scenario loss (SL). Use of the term probable maximum loss (PML) isacceptable, provided it is specifically
6、and adequately defined by the User.1. Scope1.1 This guide provides guidance on conducting seismicrisk assessments for buildings. As such, this guide assists aUser to assess a propertys potential for losses from earthquakeoccurrences.1.1.1 Hazards addressed in this guide include:1.1.1.1 Earthquake gr
7、ound shaking,1.1.1.2 Earthquake-caused site instability, including faultrupture, landslides, soil liquefaction, lateral spreading andsettlement, and1.1.1.3 Earthquake-caused off-site response impacting theproperty, including flooding from dam or dike failure, tsunamisand seiches.1.1.2 This guide doe
8、s not address the following:1.1.2.1 Earthquake-caused fires and toxic materials releases.1.1.2.2 Federal, state, or local laws and regulations ofbuilding construction or maintenance. Users are cautioned thatcurrent federal, state, and local laws and regulations may differfrom those in effect at the
9、time of the original construction ofthe building(s).1.1.2.3 Preservation of life safety.1.1.2.4 Prevention of building damage.1.1.2.5 Contractual and legal obligations between prior andsubsequent Users of seismic risk assessment reports or betweenProviders who prepared the report and those who would
10、 like touse such prior reports.1.1.2.6 Contractual and legal obligations between a Pro-vider and a User, and other parties, if any.1.1.3 It is the responsibility of the User of this guide toestablish appropriate life safety and damage prevention prac-tices and determine the applicability of current
11、regulatorylimitations prior to use.1.2 The objectives of this guide are:1.2.1 To synthesize and document guidelines for seismicrisk assessment of buildings;1.2.2 To encourage standardized seismic risk assessments;1.2.3 To establish guidelines for field observations of thesite and physical conditions
12、, and the document review andresearch considered appropriate, practical, sufficient, and rea-sonable for seismic risk assessment;1.2.4 To establish guidelines on what reasonably can beexpected of and delivered by a Provider in conducting theseismic risk assessment of buildings; and1.2.5 To establish
13、 guidelines by which a Provider cancommunicate to the User observations, opinions, and conclu-sions in a manner that is meaningful and not misleading eitherby content or by omission.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathemati
14、calconversions to SI units that are provided for information onlyand are not considered standard.1This guide is under the jurisdiction of ASTM Committee E06 on Performanceof Buildings and is the direct responsibility of Subcommittee E06.25 on WholeBuildings and Facilities.Current edition approved Ma
15、y 15, 2016. Published June 2016. Originallyapproved in 1999. Last previous edition approved in 2016 as E2026-16. DOI:10.1520/E2026-16A.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12. Referenced Documents2.1 ASTM Standards:2E631 Ter
16、minology of Building Constructions2.2 ICC Standard:3IBC International Building Code, current edition2.3 Other ReferencesThe following resource documentsprovide technical guidance for the seismic evaluation andretrofit of existing buildings:4ASCE 7-10 Minimum Design Loads for Buildings and OtherStruc
17、turesASCE 31 Seismic Evaluation of Existing Buildings5ASCE 41-13 Seismic Evaluation and Retrofit of ExistingBuildings63. Terminology3.1 Definitions:3.1.1 See Terminology E631.3.1.2 For definition of terms related to buildingconstruction, ASCE 31 and ASCE 41 provide additionalresources for understand
18、ing terminology and language relatedto seismic performance of buildings.3.1.3 For definition of terms and additional detailed infor-mation on concepts related to seismic events and structuraldesign, see references at the end of this document.3.2 Definitions of Terms Specific to This StandardThissect
19、ion provides definitions of concepts and terms specific tothis guide. The concepts and terms are an integral part of thisguide and are critical to an understanding of this guide and itsuse.3.2.1 active earthquake fault, nan earthquake fault thathas exhibited surface displacement within Holocene time
20、typically about the last 11 000 years.3.2.2 building code, na collection of laws (regulations,ordinances, or statutory requirements) applicable to buildings,adopted by governmental (legislative) authority and adminis-tered with the primary intent of protecting public health, safety,and welfare.3.2.3
21、 building systems, nall physical systems that com-prise a building and its services.3.2.3.1 DiscussionThis includes architectural, structural,mechanical, plumbing, electrical, fire life-safety, vertical trans-portation and security systems. More specifically architecturalsystems include non-structur
22、al building envelopes, roofing,ceilings, partitions, non-structural demising walls etc; struc-tural systems include both gravity and seismic force-resistingsystems and foundations; mechanical systems include heating,ventilating and air conditioning equipment, ducts, controlsystems etc; plumbing syst
23、ems include domestic water heaters,piping, controls, plumbing fixtures, waste water system pipingand natural gas or propane systems, storm water drains andpumps etc; electrical systems include switchgear, transformers,breakers, wiring, lighting fixtures, emergency power systemsetc; and fire life-saf
24、ety systems include fire sprinkler systems,monitoring and alarm systems etc. Not included in buildingsystems are those contained within a building and defined ascontents.3.2.4 business interruption, na period of interruption tonormal business operations that can potentially or materiallycause a loss
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTME2026REVA2016STANDARDGUIDEFORSEISMICRISKASSESSMENTOFBUILDINGSPDF

链接地址:http://www.mydoc123.com/p-432578.html