ANSI ASME MFC-11-2006 Measurement of Fluid Flow by Means of Coriolis Mass Flowmeters.pdf
《ANSI ASME MFC-11-2006 Measurement of Fluid Flow by Means of Coriolis Mass Flowmeters.pdf》由会员分享,可在线阅读,更多相关《ANSI ASME MFC-11-2006 Measurement of Fluid Flow by Means of Coriolis Mass Flowmeters.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、AN AMERICAN NATIONAL STANDARDMeasurement ofFluid Flow by Means of Coriolis Mass FlowmetersASME MFC-112006(Revision of ASME MFC-11M2003)Intentionally left blank ASME MFC-112006(Revision of ASME MFC-11M2003)Measurement ofFluid Flow byMeans ofCoriolis MassFlowmetersAN AMERICAN NATIONAL STANDARDThree Pa
2、rk Avenue New York, NY 10016Date of Issuance: March 30, 2007This Standard will be revised when the Society approves the issuance of a new edition. There willbe no addenda issued to this edition.ASME issues written replies to inquiries concerning interpretations of technical aspects of thisStandard.
3、Interpretations are published on the ASME Web site under the Committee Pages athttp:/cstools.asme.org as they are issued.ASME is the registered trademark of The American Society of Mechanical Engineers.This code or standard was developed under procedures accredited as meeting the criteria for Americ
4、an NationalStandards. The Standards Committee that approved the code or standard was balanced to assure that individuals fromcompetent and concerned interests have had an opportunity to participate. The proposed code or standard was madeavailable for public review and comment that provides an opport
5、unity for additional public input from industry, academia,regulatory agencies, and the public-at-large.ASME does not “approve,” “rate,” or “endorse” any item, construction, proprietary device, or activity.ASME does not take any position with respect to the validity of any patent rights asserted in c
6、onnection with anyitems mentioned in this document, and does not undertake to insure anyone utilizing a standard against liability forinfringement of any applicable letters patent, nor assume any such liability. Users of a code or standard are expresslyadvised that determination of the validity of a
7、ny such patent rights, and the risk of infringement of such rights, isentirely their own responsibility.Participation by federal agency representative(s) or person(s) affiliated with industry is not to be interpreted asgovernment or industry endorsement of this code or standard.ASME accepts responsi
8、bility for only those interpretations of this document issued in accordance with the establishedASME procedures and policies, which precludes the issuance of interpretations by individuals.No part of this document may be reproduced in any form,in an electronic retrieval system or otherwise,without t
9、he prior written permission of the publisher.The American Society of Mechanical EngineersThree Park Avenue, New York, NY 10016-5990Copyright 2007 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll rights reservedPrinted in U.S.A.CONTENTSForeword ivCommittee Roster . vCorrespondence With the MFC Commi
10、ttee . vi1 Scope 12 Terminology, Symbols, References, and Bibliography 13 Mass Flow Measurement . 64 Coriolis Flowmeter Selection and Application Guidelines . 95 Inspection and Compliance. 156 Density Measurement of Liquid. 157 Volume Flow Measurement Under Metering Conditions. 178 Additional Measur
11、ements 199 Coriolis Flow Measurement Uncertainty Analysis Procedure. 20Figures3.1.1 Principle of Operation of a Coriolis Flowmeter 74.1.3-1 Examples of Coriolis Flowmeter Performance and Pressure Loss vs. FlowRate . 104.1.3-2 Examples of Coriolis Flowmeter Performance and Pressure Loss vs. FlowRate
12、. 104.1.3-3 Examples of Coriolis Flowmeter Performance and Pressure Loss vs. FlowRate . 114.1.3-4 Examples of Coriolis Flowmeter Performance vs. Flow Rate . 11Tables2.3 Symbols . 32.4 Abbreviations 6Nonmandatory AppendicesA Flow Calibration Techniques . 23B Safety Considerations and Secondary Contai
13、nment of Coriolis Flowmeters . 25C Coriolis Flowmeter Sizing Considerations . 26iiiFOREWORDCoriolis flowmeters cover a family of devices with varying designs that depend on the Coriolisforce generated by the fluid (liquid or gas) flowing through oscillating tube(s). The primarypurpose of Coriolis fl
14、owmeters is to measure mass flow. However, some of these flowmeters alsomeasure liquid density and temperature of the oscillating tube wall. From the measurements,the mass flow of liquid or gas, liquid density, liquid volume flow, and other related quantitiescan be determined. This Standard was appr
15、oved by the American National Standards Institute(ANSI) on July 13, 2006.ivASME MFC COMMITTEEMeasurement of Fluid Flow in Closed Conduits(The following is the roster of the Committee at the time of approval of this Standard.)STANDARDS COMMITTEE OFFICERSZ. D. Husain, ChairR. J. DeBoom, Vice ChairA. L
16、. Guzman, SecretarySTANDARDS COMMITTEE PERSONNELC. J. Blechinger, Member Emeritus, ConsultantR. M. Bough, Rolls-RoyceG. P. Corpron, ConsultantR. J. DeBoom, ConsultantD. Faber, Corresponding Member, Badger Meter, Inc.R. H. Fritz, Corresponding Member, Lonestar Measurement andControlsF. D. Goodson, Em
17、erson Process Management Daniel DivisionA. L. Guzman, The American Society of Mechanical EngineersZ. D. Husain, Chevron Corp.E. H. Jones, Jr., Alternate, Chevron Petroleum TechnologyC. G. Langford, ConsultantW. M. Mattar, Invensys/Foxboro Co.SUBCOMMITTEE 11 DYNAMIC MASS FLOWMETERS (MFC)R. J. DeBoom,
18、 Chair, ConsultantG. P. Corpron, ConsultantZ. D. Husain, Chevron Corp.M. J. Keilty, Endress Hauser Flowtec AGM. S. Lee, Micro Motion, Inc.W. M. Mattar, Invensys/Foxboro Co.vG. E. Mattingly, ConsultantD. R. Mesnard, ConsultantR. W. Miller, Member Emeritus, R. W. Miller and Associates, Inc.A. M. Qurai
19、shi, American Gas AssociationB. K. Rao, ConsultantW. F. Seidl, Colorado Engineering Experiment Station, Inc.T. M. Kegel, Alternate, Colorado Engineering Experiment Station,Inc.D. W. Spitzer, Spitzer and Boyes, LLCR. N. Steven Colorado Engineering Experiment Station, Inc.D. H. Strobel, Member Emeritu
20、s, ConsultantJ. H. Vignos, Member Emeritus, ConsultantD. E. Wiklund, Rosemount, Inc.D. C. Wyatt, Wyatt EngineeringD. R. Mesnard, ConsultantA. M. Quraishi, American Gas AssociationB. K. Rao, ConsultantD. W. Spitzer, Spitzer and Boyes, LLCJ. H. Vignos, ConsultantCORRESPONDENCE WITH THE MFC COMMITTEEGe
21、neral. ASME Standards are developed and maintained with the intent to represent theconsensus of concerned interests. As such, users of this Standard may interact with the Committeeby requesting interpretations, proposing revisions, and attending committee meetings. Correspon-dence should be addresse
22、d to:Secretary, MFC Standards CommitteeThe American Society of Mechanical EngineersThree Park AvenueNew York, NY 10016-5990Proposing Revisions. Revisions are made periodically to the Standard to incorporate changesthat appear necessary or desirable, as demonstrated by the experience gained from the
23、applicationof the Standard. Approved revisions will be published periodically.The Committee welcomes proposals for revisions to this Standard. Such proposals should beas specific as possible, citing the paragraph number(s), the proposed wording, and a detaileddescription of the reasons for the propo
24、sal, including any pertinent documentation.Interpretations. Upon request, the MFC Committee will render an interpretation of any require-ment of the Standard. Interpretations can only be rendered in response to a written request sentto the Secretary of the MFC Standards Committee.The request for int
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASMEMFC112006MEASUREMENTOFFLUIDFLOWBYMEANSOFCORIOLISMASSFLOWMETERSPDF

链接地址:http://www.mydoc123.com/p-431990.html