ANSI American Society of Sanitary Engineering 1017-2009 Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems.pdf
《ANSI American Society of Sanitary Engineering 1017-2009 Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems.pdf》由会员分享,可在线阅读,更多相关《ANSI American Society of Sanitary Engineering 1017-2009 Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Temperature Actuated Mixing Valves for Hot Water Distribution Systems iASSE 1017 - 2009Performance Requirements forTemperatureActuated MixingValves for Hot Water Distribution SystemsAmerican Society of Sanitary EngineeringASSE Standard #1017-2009ASSE Board Approved: October 5, 2009ANSI Approved: Jan
2、uary 19, 2010An American National StandardTemperature Actuated Mixing Valves for Hot Water Distribution Systems iASSE 1017 - 2009American Society of Sanitary EngineeringWestlake, OhioCopyright 2009, 2003, 1998, 1986, 1979, 1976All rights reserved.Neither this standard, nor any portion thereof, may b
3、e reproduced without the written consent of the American Society of Sanitary Engineering.No product may be said to be ASSE approved unless the manufacturer has applied to ASSE, has had the product tested according to the applicable ASSE Standards, and when the product has passed the test, displays t
4、he ASSE Seal on the product.Instructions for receiving the authorization to display the Seal are available from ASSEs International Office. Organizations wishing to adopt or list any ASSE Standard should print the ASSE Standard number on the cover page first and in equal or larger type to that of th
5、e adopting or listing organization.General Informationii Temperature Actuated Mixing Valves for Hot Water Distribution SystemsASSE 1017 - 2009The foreword shall not be considered a part of this standard; however it is offered to provide background information.In the interest of consumer safety, this
6、 standard was originally issued in April, 1976; accepted by the American National Standards Institute (ANSI) in 1979 and revised in April 1986, 1998, 2003 and 2009.Water mixing (also defined as tempering or blending) valves are used extensively in water service applications to mix hot and cold water
7、 to reduce high service water temperature to the building distribution piping system.This class of valve is intended to be installed at the hot water source. These devices are designed for primary automatic control of the hot water distribution temperature within a rea-sonable degree of uniformity.T
8、o provide final temperature control, ASSE 1017 devices should be supplemented by a point-of-use device or in-line device designed to control final temperature. High temperature limit alarms and/or temperature limiting devices may also be used to monitor or further control point of use water temperat
9、ure.Recognition is made of the time volunteered by members of this working group and of the support of the manufacturers who also participated in the meetings for this standard.This standard does not imply ASSEs endorsement of a product which conforms to these requirements.Compliance with this stand
10、ard does not imply acceptance by any code body.This standard was promulgated in accordance with procedures developed by the American National Standards Institute (ANSI).ForewordTemperature Actuated Mixing Valves for Hot Water Distribution Systems iiiASSE 1017 - 2009Edward J. LyczkoProduct Standards
11、Committee ChairmanCleveland ClinicCleveland, OhioRand H. AckroydRand Technical Consulting, LLCNewburyport, MassachusettsWilliam Briggs, Jr.MGJ Associates New York, New YorkJudson W. CollinsJULYCO ProfessionalsMannford, OklahomaA. Richard EmmersonGeneral InterestBuffalo Grove, IllinoisRon GeorgeRon G
12、eorge Design and supply water between 39.0F - 80.0F (3.9C - 26.7C) to the cold water inlet. Maintain the cold water temperature to within 2.0F ( 1.1C) for the duration of the test.With V2 fully open, interactively adjust V1, the device outlet temperature adjustment and the hot and cold supply pressu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAMERICANSOCIETYOFSANITARYENGINEERING10172009PERFORMANCEREQUIREMENTSFORTEMPERATUREACTUATEDMIXINGVALVESFORHOTWATERDISTRIBUTIONSYSTEMSPDF

链接地址:http://www.mydoc123.com/p-430848.html