1、ANSI/AAMI/ISO 14408: 2005Tracheal tubes designed for laser surgeryRequirements for marking and accompanying informationAmerican National StandardThis document was approved and published when the U.S. TAG for TC 121 was held by ASTM, but it is now an AAMI standard. The original formatting has been ma
2、intained, so there are some variations from the typical AAMI style. Published by Association for the Advancement of Medical Instrumentation 4301 N. Fairfax Drive, Suite 301 Arlington, VA 22203-1633 www.aami.org 2014 by the Association for the Advancement of Medical Instrumentation All Rights Reserve
3、d This publication is subject to copyright claims of ISO, and AAMI. No part of this publication may be reproduced or distributed in any form, including an electronic retrieval system, without the prior written permission of AAMI. All requests pertaining to this document should be submitted to AAMI.
4、It is illegal under federal law (17 U.S.C. 101, et seq.) to make copies of all or any part of this document (whether internally or externally) without the prior written permission of the Association for the Advancement of Medical Instrumentation. Violators risk legal action, including civil and crim
5、inal penalties, and damages of $100,000 per offense. For permission regarding the use of all or any part of this document, complete the reprint request form at www.aami.org or contact AAMI, 4301 N. Fairfax Drive, Suite 301, Arlington, VA 22203-1633. Phone: 703-525-4890; Fax: 703-525-1067. Printed in
6、 the United States of America ISBN 1570205310 Approved as an American National Standard by ASTM International ASTM InternationalINTERNATIONALSTANDARDANSI/ISO14408Second edition2005-06-01Tracheal tubes designed for laser surgery Requirements for marking and accompanying information Tubes trachaux des
7、tins aux oprations laser Exigences relatives au marquage et aux informations daccompagnement ANSI/ISO 14408:2005(E) Approved as an American National Standard with deviations by ASTM International ASTM InternationalThese materials are subject to copyright claims of ASTM International. Not for resale
8、without the prior written permission of ASTM International. No part of this publication may be reproduced in any form, including an electronic retrieval system, without the prior written permission of ASTM International. ii ASTM International ANSI/ISO 14408:2005(E) Approved as an American National S
9、tandard with deviations by ASTM International ASTM International iiiForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technica
10、l committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely wit
11、h the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft Inter
12、national Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may
13、 be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 14408 was prepared by Technical Committee ISO/TC 121, Anaesthetic and respiratory equipment,Subcommittee SC 2, Tracheal tubes and other equipment.This second edition cancels and rep
14、laces the first edition (ISO 14408:1998), Clauses 4 and 5 and Figure 1 of which have been technically revised. For the purposes of this International Standard, the CEN annex regarding fulfilment of European Council Directives has been removed. ANSI/ISO 14408:2005(E) Approved as an American National
15、Standard with deviations by ASTM International ivASTM InternationalIntroductionThis International Standard is intended to provide requirements for marking, labelling and information supplied for tracheal tubes which are designed for resistance to ignition by a laser and which have been tested for la
16、ser resistance in accordance with ISO 11990 including a standard format for reporting results obtained when tested in accordance with ISO 11990. It is intended that, by limiting the requirements to disclosure of information determined in accordance with standard test methods, the manufacturer will b
17、e allowed maximum use of alternatives in design and materials. INTERNATIONAL STANDARD ANSI/ISO 14408:2005(E)Approved as an American National Standard with deviations by ASTM International ASTM International 1Tracheal tubes designed for laser surgery Requirements for marking and accompanying informat
18、ion 1 Scope This International Standard specifies marking, labelling and information to be supplied by the manufacturer for cuffed and uncuffed tracheal tubes and related materials designed to resist ignition by a laser. 2 Normative references The following referenced documents are indispensable for
19、 the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 11990, Optics and optical instruments Lasers and laser-related equipment Determination of laser resis
20、tance of tracheal tube shafts3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 tracheal tube tube designed for insertion through the larynx into the trachea to convey gases and vapours to and from the trachea ISO 4135:2001 3.2 cuff inflatable b
21、alloon permanently attached around the tracheal tube near the patient end to provide an effective seal between the tube and the trachea NOTE Adapted from ISO 4135:2001. 3.3 laser-resistant tracheal tube tracheal tube specifically designed by the manufacturer for use during laser surgery of the airwa
22、y NOTE This includes devices sold preassembled or in kit form. 3.4 laser-resistant tracheal tube treatment covering and/or surface treatment that adapts or modifies non-laser-resistant tracheal tubes for use in laser surgery of the airway ANSI/ISO 14408:2005(E) Approved as an American National Stand
23、ard with deviations by ASTM International 2ASTM International3.5 upper anatomical airway upper airway airway above the laryngotracheal junction 3.6 laser-resistant portion that portion of the tracheal tube intended by the manufacturer to be laser-resistant 4 Marking and labelling 4.1 Use of symbols
24、The requirements given in 4.2, 4.3, and 4.4 may be met by the use of the appropriate symbols in accordance with ISO 7000 or EN 980. 4.2 Marking 4.2.1 Marking of tracheal tubes, connectors, packages, inserts and information to be supplied by the manufacturer should comply with EN 1041. 4.2.2 The foll
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAAMI144082005TRACHEALTUBESDESIGNEDFORLASERSURGERYREQUIREMENTSFORMARKINGANDACCOMPANYINGINFORMATIONPDF

链接地址:http://www.mydoc123.com/p-430297.html