1、4100 N. FAIRFAX DR., STE. 200 ARLINGTON, VIRGINIA 222032002STANDARD forREFRIGERANTACCESSVALVES ANDHOSECONNECTORSStandard 720Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
2、Price $10.00 (M) $20.00 (NM) Copyright 2002, by Air-Conditioning and Refrigeration InstitutePrinted in U.S.A. Registered United States Patent and Trademark Office IMPORTANTSAFETY RECOMMENDATIONSIt is strongly recommended that the product be designed, constructed, assembled and installed in accordanc
3、e withnationally recognized safety requirements, appropriate for products covered by this standard.ARI, as a manufacturers trade association, uses its best efforts to develop standards, employing state-of-the-artand accepted industry practices. However, ARI does not certify or guarantee safety of an
4、y products, componentsor systems designed, tested, rated, installed or operated in accordance with these standards or that any testconducted under its standards will be non-hazardous or free from risk.Note:This standard supersedes ARI Standard 720-97.Copyright Air-Conditioning and Refrigeration Inst
5、itute Provided by IHS under license with ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE OF CONTENTSSECTION PAGESection 1. Purpose1Section 2. Scope 1Section 3. Definitions 1Section 4. Location Requirements .1Section 5. Dimensions and Materials .2Section 6.
6、 Gaging Procedures .2Section 7. Marking and Nameplate Data.2Section 8. Conformance Conditions 2TABLESTable 1. Conversion Table .5FIGURESFigure 1. Refrigerant Access Valve - Required Moveable Valve Core Pin Location3Figure 2. Refrigerant Access Valve - Typical Valve Body Dimensions 3Figure 3. Refrige
7、rant Access Valve - Typical Valve Core Dimensions 4Figure 4. Refrigerant Access Valve - Plug Gage.4Figure 5. Refrigerant Access Valve - Ball Gage5APPENDICESAppendix A. References - Normative6Appendix B. References - Informative.6Copyright Air-Conditioning and Refrigeration Institute Provided by IHS
8、under license with ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Copyright Air-Conditioning and Refrigeration Institute Provided by IHS under license with ARINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ARI STANDARD 720-20
9、021REFRIGERANT ACCESS VALVESAND HOSE CONNECTORSSection 1. Purpose1.1 Purpose. The purpose of this standard is to establishfor Refrigerant Access Valves and Hose Connectors used inrefrigeration and air-conditioning systems: definitions;location requirements; dimensions and materials; gagingprocedures
10、; marking and nameplate data; and conformanceconditions.1.1.1 Intent. This standard is intended for theguidance of the industry, including manufacturers,engineers, installers, contractors and users.1.1.2 Review and Amendment. This standard issubject to review and amendment as technologyadvances.Sect
11、ion 2. Scope2.1 Scope. This standard applies to in SAE flareRefrigerant Access Valves and Hose Connectors as definedin Section 3.2.1.1 Refrigerant. This standard applies toRefrigerant Access Valves and Hose Connectorsintended for use with Volatile Refrigerants.2.2 Exclusions.2.2.1 This standard does
12、 not apply to RefrigerantAccess Valves and Hose Connectors other than inSAE flare.Section 3. DefinitionsAll terms in this document shall follow the standard industrydefinitions in the current edition of ASHRAE Terminology ofHeating, Ventilation, Air Conditioning and Refrigerationand ANSI/SAE Standar
13、d J513f, unless otherwise defined inthis section.3.1 Refrigerant Access Valve (Valve). A normally closedvalve containing a Valve Core, incorporating a flare connectorused for the purpose of servicing refrigeration and air-conditioning systems.3.2 Refrigerant Access Valve Body (Valve Body). A flareco
14、nnector machined to permit the insertion of a Valve Core.3.2.1 Valve Core. An assembly containing a springand moveable valve core pin and seating details,suitably threaded for insertion into a Valve Body toprovide a normally closed Valve intended for use withrefrigeration and air-conditioning system
15、s. Depressionof the moveable Valve Core pin opens the Valve.3.3 Refrigerant Access Valve Hose Connector (HoseConnector). A modified internally threaded flare connectorsuitable for sealed attachment to a refrigerant hose containinga flare sealing gasket and a depressor to automaticallydepress a movea
16、ble Valve Core pin as the connector isthreaded on the Valve external flare connection.3.4 “Shall“ or “Should“. “Shall“ or “should“ shall beinterpreted as follows:3.4.1 Shall. Where “shall“ or “shall not“ is usedfor a provision specified, that provision is mandatoryif compliance with the standard is
17、claimed.3.4.2 Should. “Should“ is used to indicateprovisions which are not mandatory but which aredesirable as good practice.3.5 Volatile Refrigerant. A fluid used for heat transfer ina refrigerating system, which absorbs heat at a lowtemperature and low pressure and transfers heat at a highertemper
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARI7202002REFRIGERANTACCESSVALVESANDHOSECONNECTORS 制冷 真空管 接管 PDF

链接地址:http://www.mydoc123.com/p-429459.html