1、 FSC 6625 Comments, suggestions, or questions on this document should be addressed to: WR-ALC/742d CBSG, 380 Richard Ray, Ste 104 Robins AFB, GA 31098-1611. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:
2、/assist.daps.dla.mil . A-A-59816 4 August 2008 COMMERCIAL ITEM DESCRIPTION OPTICAL TIME DOMAIN REFLECTOMETER, SINGLE AND MULTI-MODES The general Service Administration has authorized the use of this Commercial Item Description for all federal agencies. 1. SCOPE. This Commercial Item Description(CID)
3、 describes an Optical Time Domain Reflectometer (OTDR) designed to make calibrated optical attenuation and distance measurements for the purpose of diagnosing and locating faults, components, and terminations of 850 nm/multi-mode, 1300 nm/multi-mode, 1310 nm/single-mode, and 1550 nm/single-mode wave
4、lengths using plug in laser modules. Any instrument that meets this specification will have to operate within this specified equipment environment. This CID is meant as a minimum requirement for an Optical Time Domain Reflectometer, herein referred to as an OTDR, in which only those manufacturers th
5、at meet or surpass the following requirements are qualified per this CID. 2. CLASSIFICATION. The instrument covered by this CID may be commercially available equipment modified to the extent necessary to meet the following specification. The equipment shall be Class 3 in accordance with MIL-PRF-2880
6、0 or its Commercial Standard equivalent, with the exceptions noted herein. 3. SALIENT CHARACTERISTICS. The instrument shall be capable of operation and product sample testing, if so requested, within the accuracies, limits, and specifications herein. 3.1 Operational requirements. 3.1.1 Safety. The i
7、nstrument shall meet all safety and environmental requirements as specified in MIL-PRF-28800, or its Commercial Standard equivalent, for the classification as stated herein. 3.1.2 Dynamic Range. The instrument shall provide a minimum dynamic range of 20 dB at the largest pulse width for the followin
8、g wavelengths: 85 nm/multi-mode and 1300 nm/multi-mode. The instrument shall provide a minimum dynamic range of 30 dB at the largest pulse width for the following wavelengths: 1310 nm/single-mode and 1550 nm/single-mode. 3.1.3 Attenuation Accuracy and Resolution. The instrument shall have an attenua
9、tion accuracy of at least 3% or better for all wavelengths. The instrument shall have an attenuation resolution of at least 0.01dB for all wavelengths. 3.1.4 Maximum Measurable Distance. The instrument shall provide a useable scale reading (maximum measurable distance of the fiber) of at least the f
10、ollowing: Wavelength/Mode Maximum Range 850 nm/multi-mode 15 km/ 9 miles 1300 nm/multi-mode 30 km/ 19 miles 1310 nm/single-mode 100 km/ 63 miles 1550 nm/single-mode 200 km/ 125 miles 3.1.5 Distance Resolution. The instrument shall provide a distance resolution of at least 1 meter/ 3.3 feet for all w
11、avelengths. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59816 2 3.1.6 Spatial Resolution. The instrument shall provide a spatial resolution (the smallest spacing of two closely spaced reflecting elements which can be clearly resolv
12、ed) of at least the following: Wavelength/Mode Maximum Range 850 nm/multi-mode 2 m/ 7 ft 1300 nm/multi-mode 4 m/ 13 ft 1310 nm/single-mode 8 m/ 26 ft 1550 nm/single-mode 16 m/ 52 ft 3.1.7 Reflective Dead Zone (Fresnel). The instrument shall have a maximum pulse recovery time (the amount of time requ
13、ired for the OTDR receiver to recover when the reflected power is large and the receiver is overdriven) of 5 meters/ 16 feet on the following wavelengths: 850 nm/multi-mode, 1300 nm/multi-mode, 1310 nm/single-mode, and 1550 nm/single-mode. 3.1.8 Non-Reflective Dead Zone (Backscatter). The instrument
14、 shall have a maximum Non-Reflective Dead Zone of 15 meters/ 49 feet on the following wavelengths: 85 nm/multi-mode, 1300 nm/multi-mode, 1310 nm/single-mode, and 1550 nm/single-mode. 3.1.9 Pulse Width. This instrument shall have the ability to have selectable pulse widths for both single and multi-m
15、odes. The instrument shall have the ability to select several pulse widths between 10 ns and 500 ns plus several between 1 s and 10 s. These pulse widths shall be on all of the module(s) if it uses interchangeable plug-in modules, or some other equivalent means, of accompanying this same task. 3.1.1
16、0 Real Time Monitoring. The instrument shall provide the ability to continuously update the graphical display and the alphanumeric readout. This capability shall be available for both complete trace display and expanded trace display modes of operation. 3.2 General Requirements. 3.2.1 Display, Input
17、, and Data Storage. The instrument shall be capable of both a graphical and an alphanumeric display. Graphically the instrument shall be capable of displaying an entire trace over the maximum range and shall have the capability of displaying and expanding any portion of that over the entire range. A
18、lphanumerically the instrument shall be capable of the attenuation measurements and distance measurements. The display shall be capable of displaying measurements in color. The instrument shall also be capable of providing an input users interface, as well as providing data storage capabilities inte
19、rnal and external storing of data. The instrument shall be supplied with an US style English keyboard to permit easy operation. 3.2.2 Transit Case. The instrument shall be provided with a ruggedized hard transit case. Accessory storage shall be provided for in the hard transit case. It is the Govern
20、ments intent that the transit case be able to withstand the normal situations found in exterior fiber optic maintenance. The transit case needs to withstand rain and dust and not crush under a 25 lb load. In Military Standards the transit case must be in accordance with paragraph 3.7 for Class 3 of
21、MIL-PRF-28800 or its equivalent with exceptions listed below. Commercial Standards are acceptable as long as they are equivalent. 3.2.3 Splash-proof. The Governments intent is that the transit case be water resistant. This is formally accomplished by requiring splash-proof testing. The transit case
22、shall be splash-proof to Class 1 according to MIL-PRF-28800F, paragraph 3.8.6.2. Commercial Standards may be substituted to include type of testing used to verify water resistance. 3.2.4 Dust Exposure. The Governments intent is that the transit case be dust resistant. This is formally accomplished b
23、y requiring dust exposure testing. The item and transit case shall meet Class 1 requirements as listed in MIL-PRF-28800F, paragraph 3.8.10. Commercial Standards are acceptable as long as they are equivalent. 3.2.5 Laser Design and Safety. The instruments laser modules shall meet the safety and desig
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA598162008OPTICALTIMEDOMAINREFLECTOMETERSINGLEANDMULTIMODES 模式 时域 反射 PDF

链接地址:http://www.mydoc123.com/p-427178.html