1、I I t I I I l I l l l l I l I i I I l i I l t A-A-50b9b 49 W 9999974 0062335 8 W , -1 A-8-50698 f- 11 July 1991 COMMERCIAL ITEM DESCRIPTION REELS, STATIC DISCHARGE, GROUYDIIGI, 50 AND 75 FOOT CABLE LENGTHS The General Services Administration has authorized the we of this Commercial Item Description
2、as a replacement for Military Specification MIL-B-83232 which is cancelled. Abstract. This Commercial Item Description describes industrial type static discharge reels with either 50 or 75 foot cable lengths (fully extracted) used to dispel static charges from ground support equipment. Type I - Larg
3、e (75 foot cable) Type II - Small (50 foot cable) Salient characteristics. Materials. The use of toxic or hazardous materials? as defined by the US Environmental Protection Agency, shall be the minimum consistent with performance requirements as stated herein. Metals. Those metals used shall possess
4、 low resistivity. Metals other than those specified shall be corrosion resistant or treated to resist corrosion throughout the life of the unit dile to contact with fuels, salt spray, or the following atmospheric conditions! Storage temperatures of -80 degrees to t160 degrees Fahrenheit, operational
5、 temperatures between -65 degrees and t125 degrees Fahrenheit, a relative humidity of 95 plus or minus 5 percent and airborne dust and sand particles encountered in desert operation. Fungus-Proof materials. Materials which are not nutrients for fungi shall be used to the greatest practical extent. W
6、here materials that are nutrients for fungi must be used, such materials shall be treated with a fungicidal agent commercially acceptable and compatible with those materials on which it is to be applied. Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data w
7、hich may improve this document should be sent to: San Antonio Air Logistics Center, AFLC, ATTI: SA-ALC/TIBDY, Kelly AFB, TX 78241-5000. AMSC N/A FSC- 4930 DISTBIBUTIOY STATEYEW A. Approved for public release; distribution is unlimited. I. Provided by IHSNot for ResaleNo reproduction or networking pe
8、rmitted without license from IHS-,-,-A-A-50696 49 E 9999974 00b2L3b T m A-8-50898 Dissimilar metals. Unless protected against electrolytic corrosion, dissimilar metals shall not be used in intimate contact with each other. Construction. The reel trough shall be of such size to contain the entire cab
9、le lengths as specified herein when in the fully retracted position. When bolted to an appropriate fixture, the reel and base shall be so constructed as to be capable of withstanding a static load of 150-pounds applied at the cable free end grounding device or cable free end when grounding device is
10、 not installed. Dimensions. The envelope dimensions of the reel in an upright position shall not exceed 12 inches in height, Il inches in depth, and 5 inches In width. For mounting, two 1/2 inch diameter bolt holes shall be symmetrically located in the base 7 and 7/8 inches apart on center (see figu
11、re 11. Mounting position. The unit shall be capable of operating when mounted in any position about a 360 degree axis. Cable outlet guide. A cable outlet guide shall be provided that will allow the cable to return to the reel from any position within a 90 degree arc to the plane of rotation of the r
12、eel without kinking or tangling. Automatic rewind. The reel shall be spring loaded with a spring manufac- tured from a corrosion resistant steel or one of steel that has been treated to prevent corrosion which will automatically retract the entire length of the cable extension when extended in any d
13、irection within 90 degrees from the axis of the cable outlet guide. Cable latching mechanism. The reel shall be equipped with a latching mechanism to release and restore cable tension. After latching has occurred the cable shall remain in an extended position. Further extension of cable shall cause
14、the latching mechanism to release and permit the cable to retract. Cable. The Type I reel shall contain a minimum of 75 feet of cable. The Type II reel shall contain a minimum of 50 feet of cable. The cable for the Type I and Type II reels shall be made of “7x7 strand commercial corrosion resistant
15、steel with a nominal outside diameter of 3/32 inch. The cable shall have a Y20 pound minimum breaking strength and no more than 6.67 ohms electri- cal resistance per 75 feet. This cable is not for flight control use. The cable shall be sheathed with a yellow Dupont Hytrel jacket having a 5/32 inch n
16、ominal diameter. Cable stop. A cable stop will be furnished with each unit which is cap- able of preventing the cable from being inadvertently withdrawn into the reel housing. Cable end ground devices. A welder and a grounding plug (Per MIL-C-83413/4 assembly. The cable end grounding devi style grip
17、 clamp (per MIL-C-83413/7) shall be furnished with each reel es shall not be attached to the cable. 2 . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-c I A-A-50696 49 I 7999974 0062337 3 8-8-50806 Color. The reel shall be color no. 24052 in accorda
18、nce with FED-STD-595. Cleaning, painting, plating, anodic films, and chemical treatments shall be in accordance with MIL-STD-808. e Electrical resistance. The electrical resistance between the cable free end grounding device or end of cable if no grounding device is furnished (in either extended or
19、retracted condition) and the contact surfaces on the mounting base or the reel frame shall not exceed 10 ohms. Metal components shall be electrically bonded together to prevent sparking during operation. Repairability. The unit shall contain provisions for cable replacement under field conditions. R
20、eplacement of the cable and end attachments shall be accomplished using common hand tools. Lubrication. The drum shaft bearings shall be permanently lubricated and sealed for the life of the unit. The use of grease fittings shall be limited only to the latching mechanism. Where lubricants are requir
21、ed, the reel shall so be designed that excess grease or oil cannot contaminate electrical contacts cawing disruptions in continuity of the unit. Reliability requirements. The unit provided by the contractor shall be capable of a minimum of 5000 cycles (full extensions and retractions) before failure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEAA506961991REELSSTATICDISCHARGEGROUNDING50AND75FOOTCABLELENGTHS50 75 英尺 线缆 接地 静电 放电 卷轴 PDF

链接地址:http://www.mydoc123.com/p-426854.html