1、 ANSI/AHRI Standard 540 (formerly ARI Standard 540) 2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units Price $10.00 (M) $20.00 (NM) Copyright 2004, by Air-Conditioning, Heating, and Refrigeration Institute Printed in U.S.A. Registered United St
2、ates Patent and Trademark Office IMPORTANT SAFETY RECOMMENDATIONS ARI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommende
3、d that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. ARI uses its best efforts to develop standards/guidelines employing state-of-the-ar
4、t and accepted industry practices. ARI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes ARI Standard 540-99. TABLE OF CONTENTS SECTION PAGE Section 1. Purpose 1 Section 2. Scope . 1 Section 3
5、. Definitions 1 Section 4. Test Requirements 3 Section 5. Rating Requirements . 3 Section 6. Minimum Data Requirements for Published Ratings . 3 Section 7. Operating Requirements . 7 Section 8. Marking and Nameplate Data . 7 Section 9. Conformance Conditions 7 TABLES Table 1. Standard Rating Conditi
6、ons for Compressors and Compressor Units for Commercial Refrigeration Applications 5 Table 2. Standard Rating Conditions for Compressors and Compressor Units Used In Air Conditioners and Heat Pumps 6 APPENDICES Appendix A. References - Normative 8 Appendix B. References - Informative. 8 Appendix C.
7、Method to Handle Zeotropic Mixtures - Informative . 9 FIGURES Figure C1. Cycle Process for Single Component Refrigerants and Azeotropic Mixtures 9 Figure C2. Cycle Process for Zeotropic Refrigerant Mixtures . 10 Figure C3. Definitions of Subcooling and Superheating . 11ANSI/AHRI STANDARD 540-2004 1
8、PERFORMANCE RATING OF POSITIVE DISPLACEMENT REFRIGERANT COMPRESSORS AND COMPRESSOR UNITS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish, for single and variable capacity positive displacement refrigerant compressors and compressor units: definitions; test requirements;
9、rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors and users. 1.1.2
10、Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to electric motor driven, single and variable capacity positive displacement refrigerant compressors and compressor units. This standard also applies to th
11、e presentation of performance data for positive displacement refrigerant compressors and compressor units for air-cooled, evaporatively-cooled or water-cooled air-conditioning, heat pump and refrigeration applications. 2.1.1 Refrigerant. The rating points in this standard are based on commonly used
12、refrigerants. 2.2 Exclusions. 2.2.1 This standard does not apply to compressors and compressor units employing ammonia, as covered in ARI Standard 510. 2.2.2 This standard does not apply to compressors and compressor units intended for use in: a. Household refrigerators and freezers b. Automotive ai
13、r-conditioners c. Dehumidifiers Section 3. Definitions All terms in this document will follow the standard industry definitions in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unless otherwise defined in this section. 3.1 Compressor or Compres
14、sor Unit Efficiency. The efficiency is defined by the following equation: = 100 m C (h2s- h1) / P where: m = mass flow of volatile refrigerant, lb/h kg/s h1= specific enthalpy of the refrigerant vapor entering the compressor or compressor unit, Btu/lb kJ/kg h2s= specific enthalpy of the refrigerant
15、vapor at the discharge pressure and the specific entropy of the refrigerant vapor entering the compressor or compressor unit, Btu/lb kJ/kg C = 0.2931 W/Btu/h 1.0 kW/kJ/s ANSI/AHRI STANDARD 540-2004 2 P = measured motor input power, W kW = compressor or compressor unit efficiency, %. 3.2 Positive Dis
16、placement Refrigerant Compressor. A compressor in which an increase in vapor pressure is attained by changing the internal volume of the compression chamber. 3.2.1 Hermetic Refrigerant Motor-Compressor. A compressor and motor assembly, both of which are enclosed in the same housing, with the motor o
17、perating in the refrigerant. 3.3 Positive Displacement Refrigerant Compressor Unit. A Positive Displacement Compressor with accessories, such as strainers, service valves, check valves, suction filters, oil separators, as provided by the manufacturer. This will also include variable capacity control
18、s, electronic or electro-mechanical, as supplied or specified by the manufacturer. 3.3.1 External-Drive Refrigerant Compressor Unit. An External-Drive Refrigerant Compressor with motor mounted on a structural base and with accessories as provided by the manufacturer. 3.3.2 Hermetic Refrigerant Motor
19、-Compressor Unit. A Hermetic Refrigerant Motor-Compressor with accessories as provided by the manufacturer. 3.4 Power Input. The power required from the incoming power source for the compressor(s) only, not including the power required for capacity control of the compressor or compressor unit includ
20、ing the oil heaters, motor starters, unloaders, frequency converters and other controls as specified by the manufacturer, expressed in WkW. 3.5 Published Rating. A statement of the assigned values of those performance characteristics, under stated rating conditions, by which a unit may be chosen to
21、fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature co
22、ntrolled by the manufacturer, at stated rating conditions. 3.5.1 Application Rating. A rating based on tests performed at application Rating Conditions (other than Standard Rating Conditions). 3.5.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.6 Rating Conditio
23、ns. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.6.1 Standard Rating Conditions. Rating conditions used as the basis of comparison for performance characteristics. 3.7 Refrigerating Capacity. The capacit
24、y associated with the increase in total enthalpy between the liquid refrigerant entering the expansion valve and superheated return gas multiplied by the mass flow rate of the refrigerant. 3.7.1 Maximum Capacity. The highest displacement capacity by the compressor or compressor unit expressed in ft3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AHRI5402004PERFORMANCERATINGOFPOSITIVEDISPLACEMENTREFRIGERANTCOMPRESSORSANDCOMPRESSORUNITSPDF

链接地址:http://www.mydoc123.com/p-422545.html