AECMA PREN 4611-003-2004 Aerospace series Cables electrical for general purpose single and multicore assembley XLETFE Family Part 003 Tin plated copper Operating temperatures betwe.pdf
《AECMA PREN 4611-003-2004 Aerospace series Cables electrical for general purpose single and multicore assembley XLETFE Family Part 003 Tin plated copper Operating temperatures betwe.pdf》由会员分享,可在线阅读,更多相关《AECMA PREN 4611-003-2004 Aerospace series Cables electrical for general purpose single and multicore assembley XLETFE Family Part 003 Tin plated copper Operating temperatures betwe.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、AECMA STANDARD NORME AECMA AECMA NORM Edition approved for publication prEN 461 1-003 Edition P 1 July 2004 Comments should be sent within six months Electrical Domain ICs: Descriptors: ENGLISH VERSION Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Fam
2、ily Part 003: Tin plated copper Operating temperatures, between - 65 OC and 135 OC Single extruded wall for enclosed applications UV laser printable Product standard Srie arospatiale Cbles, lectriques, dusage gnral, mono et multiconducteurs Famille XLETFE Partie 003 : Cuivre tam Tempratures de fonct
3、ionnement comprises entre - 65 “C et 135 “C Fil simple isol pour applications internes Marquable au laser UV Norme de produit Luft- und Raumfahrt Ein- und mehradrige elektrische Leitungen fr allgemeine Vewendung XLETFE Familie Teil 003: Kupfer verzinnt Betriebstemperaturen zwischen -65 “C und 135 “C
4、 Einfach extrudierte Isolierung fr interne (geschtzte) Verwendung UV-Laser bedruckbar Produktnorm This “Aerospace Series“ frestandard has been drawn up under the responsibility of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published for the needs of the Eu
5、ropean Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this frestandard, the technical content shall not be changed to an extent that interchangeabilify is affected, physically or functionally, wi
6、thout re-identification of the standard. After examination and review by users and formal agreement of AECMA-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN natio
7、nal members have then to implement the EN at national level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. 31 July 2004 after the date of publication to AECMA-STAN I I Copytight 2004 O by AECMA-STA1 Copyright Association Europeen
8、e des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 2 prEN 461 1-003:2004 Foreword This standard was reviewed by the Domain Technical Coordinator of AECMA-STANS Electrical Domain . A
9、fter inquiries and votes carried out in accordance with the rules of AECMA-STAN defined in AECMA- STANS General Process Manual. this standard has received approval for Publication . Contents Page 1 2 3 4 4.1 4.2 4.3 4.4 5 6 7 Scope . Normative references . Definitions and symbols . Materials and con
10、struction Materials Construction . Number of cores . Colour coding of cores . Required characteristics . Quality assurance . Designation 3 3 3 4 4 4 5 5 5 9 9 8 Identification and marking 9 9 Packaging, labelling and delivery lengths 9 10 Technical specification 9 Copyright Association Europeene des
11、 Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 3 prEN 461 1-003:2004 1 Scope This standard specifies the characteristics of UV laser printable, tin plated copper conductor electrical
12、 cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on-board electrical systems of aircraft operating at temperatures between - 65 OC and 135 OC, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 O00 Hz. These cables are for encl
13、osed applications e.g. within equipment or conduit; they are only suitable for open airframe use when provided with additional protection against mechanical abuse. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence. 2 Norm
14、ative references This European Standard incorporates by dated or undated reference provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. Dated references, subsequent amendments to or revisions of any
15、of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. EN 2084, EN 2235, EN 3475-1 OO*, EN 461 1-002, EN 9133, Aerospace series - Cables, electric, single-core, gen
16、eral purpose, with conductors in copper or copper alloy - Technical specification ) Aerospace series - Single and multicore electrical cables, screened and jacketed ) Aerospace series - Cables, electrical, aircraft use - Test methods - Part 700: General Aerospace series - Cables, electrical, for gen
17、eral purpose, single and multicore assembly - XLETFE Family- Part 002: General ) Aerospace series - Quality management systems - Qualification Procedure for Aerospace Standard Parts 3 Definitions and symbols See EN 3475-100. * And all its parts 1) Published as AECMA Prestandard at the date of public
18、ation of this standard Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-Page 4 prEN 461 1-003:2004 Mass kg/km max. 4 Materials and construction 4.1 Materi
19、als Conductor The cable conductors shall be made of tin plated copper according to EN 461 1-002. Insulation Single layer of extruded XLETFE For single core, it shall be possible to mark the outer insulation by UV laser printing. Minimum insulation thickness mm 4.2 Construction See EN 461 1-002, Tabl
20、e 1 and Table 2. mm min. Table 1 - Single core cables mm max. Code for nominal section 0,72 0,81 0,98 1,19 1,44 1,56 1,93 2,37 O01 002 004 006 O10 012 020 030 0,82 0,91 1 ,O8 1,35 1,59 1,82 2,10 2,54 Nominal section mm2 1,88 2,57 3,98 6,56 9,81 13,27 19,57 29,73 0,15 0,25 0,6 1 132 2 3 0,4 0,13 0,13
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AECMAPREN46110032004AEROSPACESERIESCABLESELECTRICALFORGENERALPURPOSESINGLEANDMULTICOREASSEMBLEYXLETFEFAMILYPART003TINPLATEDCOPPEROPERATINGTEMPERATURESBETWEPDF

链接地址:http://www.mydoc123.com/p-421500.html