BS PD IEC TS 62791-2015 Ultrasonics Pulse-echo scanners Low-echo sphere phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to.pdf
《BS PD IEC TS 62791-2015 Ultrasonics Pulse-echo scanners Low-echo sphere phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TS 62791-2015 Ultrasonics Pulse-echo scanners Low-echo sphere phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to.pdf(64页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards Publication Ultrasonics Pulse-echo scanners Low-echo sphere phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to a broad range of transducer types PD IEC/TS 62791:2015National foreword This Published Document is the UK implementation of IE
2、C/TS 62791:2015. The UK participation in its preparation was entrusted to Technical Committee EPL/87, Ultrasonics. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contrac
3、t. Users are responsible for its correct application. The British Standards Institution 2015. Published by BSI Standards Limited 2015 ISBN 978 0 580 80391 8 ICS 11.040.50; 17.140.50 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was publishe
4、d under the authority of the Standards Policy and Strategy Committee on 30 September 2015. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD IEC/TS 62791:2015 IEC TS 62791 Edition 1.0 2015-09 TECHNICAL SPECIFICATION Ultrasonics Pulse-echo scanners Low-echo spher
5、e phantoms and method for performance testing of gray-scale medical ultrasound scanners applicable to a broad range of transducer types INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 11.040.50; 17.140.50 ISBN 978-2-8322-2902-6 Registered trademark of the International Electrotechnical Commission Warn
6、ing! Make sure that you obtained this publication from an authorized distributor. colour inside PD IEC/TS 62791:201 2 IEC TS 62791:2015 IEC 2015 CONTENTS FOREWORD . 6 INTRODUCTION . 8 1 Scope 10 2 Normative references 10 3 Terms and definitions 10 4 Symbols 12 5 General and environmental conditions
7、. 13 6 Equipment required . 14 6.1 General . 14 6.2 Phantom geometries . 14 6.2.1 Phantoms for use in the frequency range 2 MHz to 7 MHz . 14 6.2.2 Phantoms for use in the frequency range 7 MHz to 15 MHz including “micro-convex“ arrays 14 6.2.3 Total internal-reflection surfaces 15 6.2.4 Spatially r
8、andom distribution of low-echo spheres 15 6.3 Ultrasonic properties of the tissue-mimicking (TM) phantoms 15 7 Data acquisition assuming a spatially random distribution of low-echo spheres . 16 7.1 Methodology . 16 7.2 Storage of digitized image data . 17 7.3 Digital image files available from the s
9、canner itself . 18 7.4 Image archiving systems . 18 8 Automated data analysis for quantifying low-echo sphere detectability 18 8.1 General . 18 8.2 Computation of mean pixel values (MPVs) 18 8.3 Determination of the LSNR m -value for a given depth interval . 21 8.3.1 Preliminaries . 21 8.3.2 Computa
10、tion of the LSNR n -values and LSNR m -value in a given depth interval 21 8.3.3 Standard error corresponding to each LSNR n -value 21 Annex A (informative) Example of a phantom for performance testing in the 2 MHz to 7 MHz frequency range . 22 Annex B (informative) Illustrations of the computation o
11、f LSNR m -values as a function of depth 24 Annex C (informative) Sufficient number of data images to assure reproducibility of results 29 C.1 General . 29 C.2 Phantom with low-echo sphere diameter 3,2 mm, having 2 spheres per millilitre . 29 C.3 Phantom with 2 mm-diameter, low-echo spheres and 8 sph
12、eres per millilitre 32 Annex D (informative) Example of a phantom for performance testing in the 7 MHz to 15 MHz frequency range . 36 Annex E (informative) Determination of low-echo sphere positions to within D/8 in x, y and z Cartesian coordinates 39 E.1 Procedure . 39 E.2 Argument for the choice o
13、f seven MPV nearest-neighbour sites for determining the centres of low-echo spheres 40 PD IEC/TS 62791:2015IEC TS 62791:2015 IEC 2015 3 Annex F (informative) Test of total internal reflection produced by alumina and plate- glass, plane reflectors . 41 Annex G (informative) Results of a test of repro
14、ducibility of LSNR mversus depth for a phantom with 4 mm-diameter low-echo spheres and 2 spheres per millilitre 48 Annex H (informative) Results for low-echo sphere-concentration dependence of LSNR mversus depth for phantoms with 4 mm-diameter spheres . 50 Annex I (informative) Results for low-echo
15、sphere-concentration dependence of LSNR m versus depth for phantoms with 3,2 mm-diameter spheres 53 Annex J (informative) Comparison of two different makes of scanner with similar transducers and console settings 57 Annex K (informative) Special considerations for 3-D probes 59 K.1 3-D probes operat
16、ing in 2-D imaging mode . 59 K.2 2-D arrays operating in 3-D imaging mode for determining LSNR m -values as a function of depth for reconstructed images . 59 K.3 Mechanically driven 3-D probes operating in 3-D imaging mode 59 Bibliography 60 Figure 1 Flow chart 17 Figure 2 Schematic of an image plan
17、e . 20 Figure A.1 End view of the phantom applicable for 2 MHz to 7 MHz showing the spatially random distribution of 4-mm diameter low-echo spheres . 22 Figure A.2 Top view of phantom with 4 mm-diameter, low-echo spheres 23 Figure B.1 Convex-array image of a prototype 4 mm-diameter low-echo sphere p
18、hantom for use in the 2 MHz to 7 MHz frequency range 24 Figure B.2 Auxiliary figures relating to Figure B.1 25 Figure B.3 Results corresponding to Figures B.1 and B.2, demonstrating reproducibility . 25 Figure B.4 Results corresponding to Figures B.1, B.2 and B.3 . 26 Figure B.5 One of 80 parallel l
19、inear-array images of the phantom containing 4 mm- diameter, low-echo spheres, at 4 MHz with focus at 3 cm . 26 Figure B.6 Three successive images of the set of 80, separated by D/4 equal to 1 mm 27 Figure B.7 Results for the 4 cm-wide, 3 cm-focus, linear array addressed in Figures B.5 and B.6 . 27
20、Figure B.8 Results for the 4 cm-wide, 3 cm-focus, linear array addressed in Figures B.5, B.6 and B.7, using all 80 image frames corresponding to Figure B.7 . 28 Figure C.1 One image obtained from a phantom containing 3,2 mm-diameter, low- echo spheres by using a 4 MHz linear array focused at 3 cm 29
21、 Figure C.2 Reproducibility result for two independent sets of 70 images with a mean number of low-echo sphere centres that is about 15 per 5 mm-depth interval 30 Figure C.3 Results obtained by using both sets of 70 independent images corresponding to Figure C.2 30 Figure C.4 Sector image (curved ar
22、ray) at 4,5 MHz with multiple foci at 4 cm, 8 cm and 12 cm depths; the low-echo spheres are 3,2 mm in diameter . 31 Figure C.5 Reproducibility results for a multiple-lateral-focus (4 cm, 8 cm and 12 cm) case corresponding to Figure C.4 . 31 Figure C.6 Reproducibility results for the case correspondi
23、ng to Figure C.5, except that there is a single focus at 10 cm depth 32 Figure C.7 Reproducibility results for the case corresponding to Figure C.5, except that there is a single focus at 4 cm depth 32 PD IEC/TS 62791:2015 4 IEC TS 62791:2015 IEC 2015 Figure C.8 Image of the phantom containing 2 mm-
24、diameter, low-echo spheres, made with a curved array having 1,5 cm radius of curvature, with its focus at 3 cm 33 Figure C.9 Reproducibility results corresponding to Figure C.8 33 Figure C.10 Results using all 100 images in the image set that gave rise to Figure C.9 . 34 Figure C.11 Image of the pha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTS627912015ULTRASONICSPULSEECHOSCANNERSLOWECHOSPHEREPHANTOMSANDMETHODFORPERFORMANCETESTINGOFGRAYSCALEMEDICALULTRASOUNDSCANNERSAPPLICABLETOPDF

链接地址:http://www.mydoc123.com/p-397830.html