BS PD IEC TS 62786-2017 Distributed energy resources connection with the grid《连接电网的分布式能源》.pdf
《BS PD IEC TS 62786-2017 Distributed energy resources connection with the grid《连接电网的分布式能源》.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TS 62786-2017 Distributed energy resources connection with the grid《连接电网的分布式能源》.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、Distributed energy resources connection with the grid PD IEC/TS 62786:2017 BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06 IEC TS 62786 Edition 1.0 2017-04 TECHNICAL SPECIFICATION Distributed energy resources connection with the grid INTERNATIONAL ELECTROTECHNICAL
2、COMMISSION ICS 29.240.01 ISBN 978-2-8322-4218-6 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. National foreword This British Standard is the UK implementation of IEC/TS 62786:2017. The UK pa
3、rticipation in its preparation was entrusted to Technical Committee GEL/8, Systems Aspects for Electrical Energy Supply. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a c
4、ontract. Users are responsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limited 2017 ISBN 978 0 580 85979 3 ICS 29.240.01 Compliance with a British Standard cannot confer immunity from legal obligations. This British Standard was published under
5、the authority of the Standards Policy and Strategy Committee on 30 June 2017. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD IEC/TS 62786:2017 IEC TS 62786 Edition 1.0 2017-04 TECHNICAL SPECIFICATION Distributed energy resources connection with the grid INTER
6、NATIONAL ELECTROTECHNICAL COMMISSION ICS 29.240.01 ISBN 978-2-8322-4218-6 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. PD IEC/TS 62786:2017 2 IEC TS 62786:2017 IEC 2017 CONTENTS FOREWORD .
7、4 1 Scope and object . 6 2 Normative references 6 3 Terms and definitions 6 4 Requirements on generating plants . 11 4.1 General . 11 4.2 Connection scheme 12 4.3 Choice of switchgear . 12 4.3.1 General . 12 4.3.2 Interface switch . 12 4.4 Normal operating range 12 4.4.1 General . 12 4.4.2 Operating
8、 frequency range 12 4.4.3 Operating voltage range 13 4.5 Immunity to disturbances 13 4.5.1 General . 13 4.5.2 Rate of change of frequency (ROCOF) immunity . 13 4.5.3 Under voltage ride through (UVRT) requirements 13 4.5.4 Over voltage ride through (OVRT) requirements 14 4.6 Active power response to
9、frequency deviation . 14 4.7 Reactive power response to voltage variations and voltage changes . 15 4.7.1 General . 15 4.7.2 Reactive power control 15 4.7.3 Dynamic reactive power support capabilities 15 4.8 EMC and power quality . 15 4.8.1 General . 15 4.8.2 Direct current (DC) injection 16 4.9 Int
10、erface protection . 16 4.10 Connection and start to generate electrical power . 17 4.10.1 General . 17 4.10.2 Connection of synchronous generators 17 4.10.3 Auto reclose of distribution lines 17 4.11 Active power management 18 4.12 Monitoring, control and communication . 18 4.12.1 Monitoring and con
11、trol . 18 4.12.2 Communication 18 5 Conformance tests 18 Annex A (normative) Operating frequency range . 19 Annex B (normative) Operating voltage range . 20 Annex C (normative) Under voltage ride through capability of DERs . 21 Annex D (normative) Over voltage ride through parameters 22 Bibliography
12、 23 Figure 1 Electricity generating plant connected to a distribution network (schematic view of switches) 10 Figure 2 Under voltage ride through capability requirements of DER . 14 PD IEC/TS 62786:2017 2 IEC TS 62786:2017 IEC 2017 CONTENTS FOREWORD . 4 1 Scope and object . 6 2 Normative references
13、6 3 Terms and definitions 6 4 Requirements on generating plants . 11 4.1 General . 11 4.2 Connection scheme 12 4.3 Choice of switchgear . 12 4.3.1 General . 12 4.3.2 Interface switch . 12 4.4 Normal operating range 12 4.4.1 General . 12 4.4.2 Operating frequency range 12 4.4.3 Operating voltage rang
14、e 13 4.5 Immunity to disturbances 13 4.5.1 General . 13 4.5.2 Rate of change of frequency (ROCOF) immunity . 13 4.5.3 Under voltage ride through (UVRT) requirements 13 4.5.4 Over voltage ride through (OVRT) requirements 14 4.6 Active power response to frequency deviation . 14 4.7 Reactive power resp
15、onse to voltage variations and voltage changes . 15 4.7.1 General . 15 4.7.2 Reactive power control 15 4.7.3 Dynamic reactive power support capabilities 15 4.8 EMC and power quality . 15 4.8.1 General . 15 4.8.2 Direct current (DC) injection 16 4.9 Interface protection . 16 4.10 Connection and start
16、 to generate electrical power . 17 4.10.1 General . 17 4.10.2 Connection of synchronous generators 17 4.10.3 Auto reclose of distribution lines 17 4.11 Active power management 18 4.12 Monitoring, control and communication . 18 4.12.1 Monitoring and control . 18 4.12.2 Communication 18 5 Conformance
17、tests 18 Annex A (normative) Operating frequency range . 19 Annex B (normative) Operating voltage range . 20 Annex C (normative) Under voltage ride through capability of DERs . 21 Annex D (normative) Over voltage ride through parameters 22 Bibliography 23 Figure 1 Electricity generating plant connec
18、ted to a distribution network (schematic view of switches) 10 Figure 2 Under voltage ride through capability requirements of DER . 14 IEC TS 62786:2017 IEC 2017 3 Table 1 Operating frequency requirements of DERs . 13 Table 2 Operating voltage requirements of DERs . 13 Table 3 Interface protection fu
19、nctions 17 Table A.1 Continuous operating frequency range . 19 Table A.2 Limited operating frequency range . 19 Table B.1 Continuous operating voltage range . 20 Table B.2 Limited operating voltage range . 20 Table C.1 UVRT capability of DERs with an interface to the grid based on a synchronous gene
20、rator . 21 Table C.2 UVRT capability of DERs with an interface to the grid based on non- synchronous generators (eg. converters, DFIG, etc.) . 21 Table D.1 Medium voltage OVRT requirements 22 PD IEC/TS 62786:2017 4 IEC TS 62786:2017 IEC 2017 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ DISTRIBUTED EN
21、ERGY RESOURCES CONNECTION WITH THE GRID FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all que
22、stions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publicatio
23、n(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC co
24、llaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTS627862017DISTRIBUTEDENERGYRESOURCESCONNECTIONWITHTHEGRID 连接 电网 分布式 能源 PDF

链接地址:http://www.mydoc123.com/p-397829.html