BS ISO 7718-2-2016 en_1749 Aircraft Passenger doors interface requirements for connection of passenger boarding bridge or passenger transfer vehicle Upper deck doors《航空器.乘客登机桥或机.pdf
《BS ISO 7718-2-2016 en_1749 Aircraft Passenger doors interface requirements for connection of passenger boarding bridge or passenger transfer vehicle Upper deck doors《航空器.乘客登机桥或机.pdf》由会员分享,可在线阅读,更多相关《BS ISO 7718-2-2016 en_1749 Aircraft Passenger doors interface requirements for connection of passenger boarding bridge or passenger transfer vehicle Upper deck doors《航空器.乘客登机桥或机.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BS ISO 7718-2:2016 Aircraft Passenger doors interface requirements for connection of passenger boarding bridge or passenger transfer vehicle Part 2: Upper deck doors BSI Standards Publication WB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS ISO 7718-2:2016 BRITISH STANDARD National forewor
2、d This British Standard is the UK implementation of ISO 7718-2:2016. It supersedes BS ISO 7718-2:2009 which is withdrawn. The UK participation in its preparation was entrusted to Technical Committee ACE/57, Air Cargo Figure 1 has been modified; additional editorial changes have been made, such as by
3、 adding a table of contents. A list of all parts in the ISO 7718 series can be found on the ISO website.iv ISO 2016 All rights reservedBS ISO 7718-2:2016ISO 7718-2:2016(E) Introduction This document specifies minimum dimensional and unobstructed space requirements around upper deck passenger doors o
4、n the outer skin of civil transport aircraft, applicable when these doors are designed to accept connection of existing passenger boarding bridges or transfer vehicles. Throughout this document, the minimum essential criteria are identified by use of the keyword “shall”. Recommended criteria are ide
5、ntified by use of the keyword “should” and, while not mandatory, are considered to be of primary importance in providing easily and economically handled aircraft, as well as preventing damage to the aircraft as a result of passenger boarding bridge interference. Deviation from recommended criteria c
6、an only occur, after careful consideration, if positively required by basic aircraft-design factors with a significant operational cost impact. ISO 2016 All rights reserved vBS ISO 7718-2:2016BS ISO 7718-2:2016Aircraft Passenger doors interface requirements for connection of passenger boarding bridg
7、e or passenger transfer vehicle Part 2: Upper deck doors 1 Scope This document specifies the minimum dimensional and unobstructed space requirements around future civil-passenger transport aircraft upper deck passenger doors when they are intended to be compatible with passenger boarding bridges pla
8、nned in airports worldwide. This document is not applicable to existing models of civil transport aircraft, or derivative models with entry into service up to year 2000 with the same fuselage, for which the aircraft-mating section of passenger boarding bridges or passenger transfer vehicles is expec
9、ted to be compatible with ISO 16004. However, it is expected that the design of such aircraft types may be taken into account for design of passenger boarding bridges capable of upper deck servicing, in addition to this document. It is not the intent of this document to restrict in any way the basic
10、 design of any future types of civil- passenger transport aircraft. It aims, however, at clarifying for aircraft design engineers the design characteristics which would make it difficult or impossible for a new type of aircraft to adequately connect with airport passenger boarding bridges. Should ba
11、sic aircraft design requirements impose on a future model certain dimensional characteristics not complying with this document, note that: either alternative methods of embarking/disembarking passengers will need to be implemented, such as using the internal aircraft stairs, etc.; or upper deck pass
12、enger boarding bridges in the airports where such a new type of aircraft is to operate will require some degree of modification/reworking; or additional interface devices/equipment will be required in order to connect such a new type of aircraft with existing upper deck passenger boarding bridges. E
13、ach case results in increased aircraft-handling constraints and operating cost. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies.
14、For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 7718-1, Aircraft Passenger doors interface requirements for connection of passenger boarding bridge Part 1: Main deck doors ISO 16004, Aircraft ground equipment Passenger boarding bridge or
15、transfer vehicle Interface requirements with aircraft doors 3 T erms a nd definiti ons No terms and definitions are listed in this document. INTERNATIONAL ST ANDARD ISO 7718-2:2016(E) ISO 2016 All rights reserved 1BS ISO 7718-2:2016ISO 7718-2:2016(E) ISO and IEC maintain terminological databases for
16、 use in standardization at the following addresses: IEC Electropedia: available at http:/ /www.electropedia.org/ ISO Online browsing platform: available at http:/ /www.iso.org/obp 4 Requirements 4.1 Minimum unobstructed space 4.1.1 Unobstructed space shall be provided for the connection of the passe
17、nger boarding bridge or passenger transfer vehicle as shown by the hatched area in Figure 1. The area bound by the dotted line represents the opening of the bridge or vehicle. 4.1.2 This area shall be kept completely clear of any external features such as aerials, drains, pitot heads, static ports,
18、sensors, incidence probes, aerodynamic strakes, access panels, etc. 4.1.3 Protrusions intended to divert rainwater away from the door opening are allowable in this area, provided they are not deemed part of the aircrafts structural or aerodynamic integrity and they do not interfere with the deployme
19、nt of the PBB canopy. 4.2 Minimum radius of the fuselage The cross-section radius of the fuselage in any part of the area defined in Figure 1 should not be less than 1,6 m (63 in). 4.3 Door sill height The passenger door sill height above the ground, at any part of its excursion range during normal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO771822016EN_1749AIRCRAFTPASSENGERDOORSINTERFACEREQUIREMENTSFORCONNECTIONOFPASSENGERBOARDINGBRIDGEORPASSENGERTRANSFERVEHICLEUPPERDECKDOORS

链接地址:http://www.mydoc123.com/p-391545.html