1、Designation: F3291 17Standard Test Method forMeasuring the Force-Resistance of a Membrane ForceSensor1This standard is issued under the fixed designation F3291; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the force versus resistancemeasurement of a membrane force sensor (MFS) where theelectrical resistance d
3、ecreases as the force on the sensor isincreased.1.2 An MFS may or may not be electrically open in its staticstate. This depends on the attributes required for the applica-tion. If the MFS has a measureable resistance in static state, itwas most likely designed to be used as a variable resistor, nota
4、s a normally open switch.Ahigh but measurable resistance, instatic state, may still be considered an open switch if theresistance is above the closed resistance threshold recognizedby the interface electronics.1.3 Special printed conductive polymer inks orcharacteristics, or both, of the sensor desi
5、gn are used in MFSto achieve variable resistance when compressed. As force isapplied to the MFS the resistance continues to decrease, but notlinearly, until a point where additional force does not changethe resistance appreciably. Ideally, when force is removed fromthe MFS the resistance will return
6、 to, or close to, its originalvalue.1.4 Materials other than conductive polymers can be used inan MFS and also exhibit reduced resistance with increasingforce.1.5 This test method should not be confused with TestMethod F2592 for measuring the force-displacement charac-teristics of a membrane switch
7、(MS) that is designed formomentary closure. Although the resistance of a MS doeschange during contact closure the change from high resistanceto contact resistance is very sudden and additional force doesnot have a significant effect on the resistance; that is, an MS isnot designed to be used as a va
8、riable resistor.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitati
9、ons prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization Tec
10、hnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:F2592 Test Method for Measuring the Force-Displacementof a Membrane SwitchF1578 Test Method for Contact Closure Cycling of a Mem-brane Switch3. Terminology3.1 Definitions:3.1.1 force at initial measurable resistance (F
11、im), nforceat Rim. If there is a measurable resistance Rim at Fss then bothFss = Fim =0.3.1.2 initial measurable resistance (Rim), nresistance ofMFS without force applied (if measurable) or the first measur-able resistance when test probe begins applying force.3.1.3 maximum sensor force (Fmaxs), na
12、special maxi-mum force to be applied to MFS during test or the force atwhich no appreciable change in resistance is noted, also knownas saturation resistance.3.1.4 maximum sensor pressure (Pmaxs), nFmaxs/surfacearea of test probe in contact with MFS.3.1.5 membrane force sensor (MFS), nsimilar in con
13、struc-tion to a non-tactile membrane switch (MS) but the measuredresistance is designed to decrease as force applied is increased.Also sometimes referred to in the industry as a force sensingresistor.3.1.6 membrane switch (MS), na momentary switchingdevice in which at least one contact is on, or mad
14、e of, a flexiblesubstsrate.3.1.7 pressure at initial measurable resistance (Pim),nFim/surface area of test probe in contact with MFS.3.1.8 Rmaxs, nresistance at Fmax.1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.1
15、8 on PrintedElectronics.Current edition approved Nov. 1, 2017. Published November 2017. DOI:10.1520/F3291-17Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally re
16、cognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.1.9 test probe tip diameter (Dtp), ndiameter of the testpro
17、be tip (or actuator) that is in contact with MFS during test.3.1.10 zero force steady state (Fss), nsteady state condi-tion before test begins, no probe force applied, Fss = 0. If thereis a measurable resistance Rim at Fss then Fim is also 0.4. Significance and Use4.1 An MFS has similar properties t
18、o a load cell or straingauge. However, an MFS is not suitable for precision measure-ments.4.2 MFS pressure versus resistance data can be calculated ifthe force probe is providing uniform pressure over a distributedarea or if the sensor is exposed to measurable air or hydraulicpressure.4.3 MFS force-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM F3291-17 Standard Test Method for Measuring the Force-Resistance of Membrane Force Sensor F3291

链接地址:http://www.mydoc123.com/p-348210.html