1、Designation: E2402 11 (Reapproved 2017)Standard Test Method forMass Loss and Residue Measurement Validation ofThermogravimetric Analyzers1This standard is issued under the fixed designation E2402; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method provides procedures for validatingmass loss and residue measurements by the
3、rmogravimetricanalyzers (TGA) and analytical methods based upon themeasurement of mass loss or residue content. Performanceparameters determined include mass loss and residue repeat-ability (precision), detection limit, quantitation limit, linearity,and bias.1.2 Validation of apparatus performance a
4、nd analyticalmethods is requested or required for quality initiatives or whereresults may be used for legal purposes.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 There is no ISO standard equivalent to this test method
5、.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to us
6、e.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers
7、to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE473 Terminology Relating to Thermal Analysis and Rhe-ologyE1142 Terminology Relating to Thermophysical PropertiesE1582 Test Method for Temperature Calibration
8、 of Thermo-gravimetric AnalyzersE1970 Practice for Statistical Treatment of ThermoanalyticalDataE2040 Test Method for Mass Scale Calibration of Thermo-gravimetric AnalyzersE2161 Terminology Relating to Performance Validation inThermal Analysis and Rheology2.2 Other Standard:U.S. FDA Q2B Validation o
9、f Analytical Procedures:Methodology, 62 FR 27464, May 19, 199733. Terminology3.1 Technical terms used in this standard are defined inPractice E177 and in Terminologies E473, E1142, and E2161.3.2 Definitions of Terms Specific to This Standard:3.2.1 highly volatile mattermaterials (such as moisture,pl
10、asticizer, residual solvent, etc.) that boil at temperaturesbelow 200C.3.2.2 medium volatile mattermaterials (such as oil andpolymer degradation products) that boil in the temperaturerange between 200 and 400C.3.2.3 residuematerial remaining (such as metalcomponents, filler content or inert reinforc
11、ing materials) aftermore volatile components are vaporized.3.2.4 mass loss plateaua region of a thermogravimetriccurve with a relatively constant mass (that is, accompanied bya minima in the first derivative of mass with respect to time).4. Summary of Test Method4.1 Mass is the primary dependent par
12、ameter and tempera-ture is the primary independent parameter measured by TGA.4.2 Mass loss and residue measurements are validated bytheir direct measurement using thermogravimetric apparatus1This test method is under the jurisdiction ofASTM Committee E37 on ThermalMeasurements and is the direct resp
13、onsibility of Subcommittee E37.10 onFundamental, Statistical and Mechanical Properties.Current edition approved Dec. 15, 2017. Published December 2017. Originallyapproved in 2005. Last previous edition approved in 2011 as E2402 11. DOI:10.1520/E2402-11R17.2For referenced ASTM standards, visit the AS
14、TM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Food and Drug Administration (FDA), 10903 NewHampshire Ave., Silver Spring, MD 20993
15、-0002, http:/www.fda.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles fo
16、r theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1over a specified temperature range using reference materials ofknown volatiles content as an analyte.4.3 Alternatively, validation of a TGA meth
17、od based uponmass loss and residue measurements may be performed usinga specific test specimen as the analyte.4.4 The mass loss of three or more specimens (nominallyrepresenting the maximum, midpoint, and minimum of therange of this test method) is measured at least in triplicate. Afourth blank spec
18、imen, containing no analyte, is also measuredat least in triplicate.NOTE 1Repeatability is determined by performing a sufficient numberof determinations to calculate statistically valid estimates of the standarddeviation or relative standard deviation of the measurements.4.4.1 Mass loss and residue
19、linearity and bias are deter-mined from the best-fit straight-line correlation of the resultsfrom measurements of the three or more specimens.4.4.2 Mass loss and residue detection limit and quantitationlimit are determined from the standard deviation of the blankspecimen measurements.4.4.3 Mass loss
20、 and residue repeatability are determinedfrom the repeatability measurements of the three or moreanalyte-containing specimens.5. Significance and Use5.1 This test method may be used to validate the perfor-mance of a specific TGA apparatus.5.2 This test method may be used to validate the perfor-mance
21、 of a specific method based upon a TGA mass loss orresidue measurement.5.3 This test method may be used to determine the repeat-ability of a specific apparatus, operator or laboratory.5.4 This test method may be used for specification andregulatory compliance purposes.6. Interferences6.1 This test m
22、ethod depends upon distinctive thermalstability ranges of the measured components as a principle ofthe test. For this reason, impurities or other materials that haveno well-defined thermally stable range, or the thermal stabilityof which are the same as other components, may createinterferences.7. A
23、pparatus7.1 Thermogravimetric Analyzer (TGA)The essential in-strumentation required to provide minimum thermogravimetrycapability for this test method includes:7.1.1 A thermobalance composed of:7.1.1.1 A furnace to provide uniform controlled heating of aspecimen to a constant temperature of 400C and
24、 at a constantrate between 5 and 25C/min.7.1.1.2 A temperature sensor to provide an indication of thespecimen/furnace temperature to 60.1C.7.1.1.3 A continuous recording balance with a minimumcapacity of 100 mg and a sensitivity of 610 g to measure thespecimen mass.7.1.1.4 A means of maintaining the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM E2402 11 2017 Standard Test Method for Mass Loss and Residue Measurement Validation of Thermogravimetric Analyzers

链接地址:http://www.mydoc123.com/p-298629.html