ASTM F2390-12(2017) Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent (DWV) Pipe and Fittings Having Post-Industrial Recycle Content.pdf
《ASTM F2390-12(2017) Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent (DWV) Pipe and Fittings Having Post-Industrial Recycle Content.pdf》由会员分享,可在线阅读,更多相关《ASTM F2390-12(2017) Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent (DWV) Pipe and Fittings Having Post-Industrial Recycle Content.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2390 12 (Reapproved 2017) An American National StandardStandard Specification forPoly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent(DWV) Pipe and Fittings Having Post-Industrial RecycleContent1This standard is issued under the fixed designation F2390; the number immediately foll
2、owing the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specificat
3、ion covers requirements and test methodsfor materials, dimensions and tolerances, pipe stiffness, crushresistance, impact resistance, hydrostatic burst resistance, andsolvent cement for poly(vinyl chloride) plastic drain, waste,and vent (DWV) pipe and fittings.1.2 The values stated in inch-pound uni
4、ts are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 The text of this specification references notes, footnotes,and appendixes which provide explanatory material. Thesenotes
5、 and footnotes (excluding those in tables and figures) shallnot be considered as requirements of the specification.1.4 The following safety hazards caveat pertains only to thetest methods portion, Section 7, of this specification. Thisstandard does not purport to address all of the safety concerns,i
6、f any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety, health andenvironmental practices and determine the applicability ofregulatory limitations prior to use.NOTE 1Pressurized (compressed) air or other compressed gasescontain large amou
7、nts of stored energy which present serious safetyhazards should a system fail for any reason.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Stand
8、ards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD1599 Test Method for Resistance to Short-Time HydraulicPressure of Plastic Pipe, Tubing,
9、and FittingsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD2412 Test Method for Determin
10、ation of External LoadingCharacteristics of Plastic Pipe by Parallel-Plate LoadingD2444 Test Method for Determination of the Impact Resis-tance of Thermoplastic Pipe and Fittings by Means of aTup (Falling Weight)D2564 Specification for Solvent Cements for Poly(VinylChloride) (PVC) Plastic Piping Sys
11、temsF2135 Specification for Molded Drain, Waste, and Vent(DWV) Short-Pattern Plastic FittingsD3311 Specification for Drain, Waste, and Vent (DWV)Plastic Fittings PatternsF402 Practice for Safe Handling of Solvent Cements,Primers, and Cleaners Used for Joining ThermoplasticPipe and FittingsF412 Termi
12、nology Relating to Plastic Piping SystemsF1498 Specification for Taper Pipe Threads 60 for Thermo-plastic Pipe and FittingsF1866 Specification for Poly (Vinyl Chloride) (PVC) PlasticSchedule 40 Drainage and DWV Fabricated Fittings1This specification is under the jurisdiction of ASTM Committee F17 on
13、 PlasticPiping Systems and is the direct responsibility of Subcommittee F17.63 on DWV.Current edition approved Aug. 1, 2017. Published September 2017. Originallyapproved in 2007. Last previous edition approved in 2012 as F239012. DOI:10.1520/F2390-12R17.2For referenced ASTM standards, visit the ASTM
14、 website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Har
15、bor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendat
16、ions issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13. Terminology3.1 Definitions Definitions are in accordance with Termi-nology in F412, and abbreviations are in accordance withTerminology in D1600, unless otherwise specified.3.2 Definitions of Terms Specific t
17、o This Standard:3.2.1 certificate of composition disclosure, na certificatedescribing certain properties of an external recycled material,its formulation and source, and the specific material shipmentto which it applies.3.2.1.1 DiscussionExamples include polymer(s), molecu-lar weight, percentage (an
18、d type) of inorganic material, tensilestrength, modulus of elasticity, and izod impact; code ordesignation identifying the formulation and source informa-tion.3.2.2 post-industrial recycle, nrecycled PVC materialgenerated by a company or manufacturing plant that is differentthan the location produci
19、ng products to this specification.3.2.2.1 DiscussionMaterial used for a different productproduced by the same manufacturer shall be considered aspost-industrial recycle material for the product of this standard,unless the different product is made from the same compound.3.2.3 post-consumer recycle,
20、nPVC plastic material usedin products that have proceeded into the chain of commercebeyond the control of the original manufacturer.3.2.3.1 DiscussionThese materials are generally recycledby the users or consumers of the product, and have no specificidentity or specificity of the compound.3.2.3.2 Di
21、scussionPost-consumer recycled material isNOT post-industrial recycle and is prohibited from use inproducts within this specification (see 5.4.1)4. Significance and Use4.1 The requirements of this specification are intended toprovide pipe and fittings suitable for the drainage and ventingof sewage a
22、nd certain other liquid wastes.NOTE 2This standard specifies dimensional, performance and testrequirements for plumbing and fluid handling, but does not addressventing of combustion gases.NOTE 3Industrial waste disposal lines should be installed only withthe specific approval of the cognizant buildi
23、ng code authority sincechemicals not commonly found in drains and sewers and temperatures inexcess of 180 F (82.2 C) may be encountered.5. Materials5.1 Basic MaterialsThe pipe and fittings shall be madefrom a uniform blend containing virgin PVC compound andbetween 10 % by weight and 50 % by weight o
24、f post-industrialrecycle material. The finished compound shall meet or exceedthe minimum cell classification material requirements specifiedin 5.2, Virgin PVC Compounds.5.2 Virgin PVC CompoundsVirgin PVC pipe compoundsshall meet or exceed the requirements of Class 12454 asdefined in Specification D1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM F2390 12 2017 Standard Specification for Poly Vinyl Chloride PVC Plastic Drain Waste and Vent DWV Pipe Fittings Having Post Industrial Recycle Content

链接地址:http://www.mydoc123.com/p-291249.html