ASTM F2045-00(2018)e1 Standard Specification for Indicators, Sight, Liquid Level, Direct and Indirect Reading, Tubular GlassPlastic.pdf
《ASTM F2045-00(2018)e1 Standard Specification for Indicators, Sight, Liquid Level, Direct and Indirect Reading, Tubular GlassPlastic.pdf》由会员分享,可在线阅读,更多相关《ASTM F2045-00(2018)e1 Standard Specification for Indicators, Sight, Liquid Level, Direct and Indirect Reading, Tubular GlassPlastic.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2045 00 (Reapproved 2018)1An American National StandardStandard Specification forIndicators, Sight, Liquid Level, Direct and Indirect Reading,Tubular Glass/Plastic1This standard is issued under the fixed designation F2045; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.
3、Department of Defense.1NOTEA key was editorially added to Fig. 1 in January 2018.1. Scope1.1 This specification covers the requirements for direct andindirect reading sight liquid level indicators for general appli-cations. General applications for indirect reading sight glassesare water and fuel se
4、rvice at working pressures 2.07 MPa (300lb/in.2) and below, temperatures of 149C (300F) and below.General applications for direct reading sight glasses are appli-cations in which the temperature does not exceed 66C(150F).1.2 Direct reading sight glass indicators may consist of glassor plastic tubes
5、with fittings including shutoff valves. Glasstubes may be used for low shock direct reading sight glassindicators in which the fluid is not compatible with plastic.1.3 Indirect reading indicators may consist of a sealedchamber with a magnetic float or flag indicator.1.4 Special requirements for nava
6、l shipboard applicationsare included in the supplement to this standard.1.5 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.6 This in
7、ternational standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT
8、) Committee.2. Referenced Documents2.1 ASTM Standards:2D3951 Practice for Commercial Packaging2.2 ANSI Standards:3B16.5 Pipe Flanges and Flanged Fittings (DoD adopted)3. Terminology3.1 Definitions:3.1.1 SI (Le Systeme International dUnites) Unitsunits ofmeasurement recognized by the CIPM (Comite Int
9、ernationaldes Poids et Mesures).4. Design Classification4.1 TypesIndicator designs are classified as either directreading or indirect reading. Both types are depicted in Fig. 1,complete with dimensions that facilitate ordering.4.2 Special ConsiderationsSpecial considerations thatmay affect selection
10、 and installation are listed below. This isnot to be construed as a complete listing.(1) Type of indicator,(2) Manual or automatic shutoff valves,(3) Indication length of liquid level range,(4) Method of connection,(5) Location of indicator relative to vibrating equipment,(6) Protection of the instr
11、umentation,(7) Application of each indicator,(8) Cleaning procedure or reference to the cleaning proce-dure being used, and1This specification is under the jurisdiction of ASTM Committee F25 on Shipsand Marine Technology and is the direct responsibility of Subcommittee F25.10 onElectrical.Current ed
12、ition approved Jan. 1, 2018. Published January 2018. Originallyapproved in 2000. Last previous edition approved in 2011 as F2045 00 (2011).DOI: 10.1520/F2045-00R18E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual
13、Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, W
14、est Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World
15、Trade Organization Technical Barriers to Trade (TBT) Committee.1(9) Selection of indicator for compatibility with materials,temperature, pressure, ambient environment, and with theparameter being measured.5. Ordering Information5.1 The buyer shall provide the manufacturer with all of thepertinent ap
16、plication data outlined in the acquisition require-ments.5.2 Acquisition RequirementsAcquisition documents shallspecify the following:(1) Title, number, and date of this specification;(2) Type and quantity of indicators required;(3) Manufacturers part number;(4) When qualification testing is require
17、d;(5) Final disposition of qualification test samples;(6) Environmental requirements;(7) Operating media;(8) Viscosity and specific gravity of fluid for indirectindicators;(9) Materials;(10) Indication length;(11) Size and type of connections;(12) Shutoff valve requirements;(13) Cleaning requirement
18、s;(14) When certification is required;(15) Marking requirements;(16) Unique packaging requirements; and(17) Unique preservation requirements.Dimensions (mm)A Distance between center of top attachment flange face and top of indicator tubeB Distance between center of bottom attachment flange face and
19、bottom of indicator tubeC Length of piping between outer tube wall and connection to tank attachment flangeD Distance between outer tube wall and outer edge of tank attachment flangeL Distance between center of attachment flange facesFIG. 1 Indicator Design TypesF2045 00 (2018)126. Materials and Man
20、ufacture6.1 MaterialsThe materials for all wetted parts shall beselected for long-term compatibility with the process mediumand ambient conditions.6.2 Material InspectionThe manufacturer shall be respon-sible for ensuring that materials used are manufactured,examined, and tested in accordance with t
21、he specifications andstandards as applicable.6.3 Gaskets and O-RingsGaskets and O-rings shall befabricated of materials suitable to the operating pressure,temperature, and process medium for each application.7. Physical Properties7.1 ConnectionsSight indicators are usually installed us-ing standard
22、pipe fittings or flanges. Pipe fittings and materialshould match that of the existing pipe for each installation.Type and size of fittings shall be specified in the acquisitionrequirements. Welding or brazing shall be performed in accor-dance with industry standards.7.2 Flanged ConnectionsWhere sigh
23、t indicators are in-stalled using flanges, flanges shall be in accordance with ANSIB16.5. Standard flange sizes include 1.27 cm (12 in.), 1.9 cm(34 in.), 2.54 cm (1 in.), 3.8 cm (1-12 in.), and 5.08 cm (2 in.).Standard flange pressure ratings include 1.034 MPa (150 psi),2.07 MPa (300 psi), and 4.14
24、MPa (600 psi). Other flangerequirements shall be specified in the acquisition requirements.7.3 Vent and Drain ConnectionsWhere required, vent anddrain connections are usually plugged,12-or34-in. NPT orwith NPT valves. Other vent and drain connections shall bespecified in the acquisition requirements
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM F2045 00 2018 e1 Standard Specification for Indicators Sight Liquid Level Direct and Indirect Reading Tubular GlassPlastic

链接地址:http://www.mydoc123.com/p-287176.html