ASTM E651 E651M - 01(2008) Standard Practice for Evaluating Capabilities of Agencies Involved in System Analysis and Compliance Assurance for Manufactured Building (Withdrawn 2017).pdf
《ASTM E651 E651M - 01(2008) Standard Practice for Evaluating Capabilities of Agencies Involved in System Analysis and Compliance Assurance for Manufactured Building (Withdrawn 2017).pdf》由会员分享,可在线阅读,更多相关《ASTM E651 E651M - 01(2008) Standard Practice for Evaluating Capabilities of Agencies Involved in System Analysis and Compliance Assurance for Manufactured Building (Withdrawn 2017).pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E651/E651M 01 (Reapproved 2008) An American National StandardStandard Practice forEvaluating Capabilities of Agencies Involved in SystemAnalysis and Compliance Assurance for ManufacturedBuilding1This standard is issued under the fixed designation E651/E651M; the number immediately follo
2、wing the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is
3、intended as a companion standard toSpecification E541, Specification for Agencies Engaged inSystem Analysis and Compliance Assurance for ManufacturedBuilding. Specification E541 covers criteria by which thetechnical resources of agencies may be evaluated for theircapability to perform the system ana
4、lysis or complianceassurance function, or both, in the evaluation and inspection ofmanufactured building. This standard2includes questions thatshould be asked of system analysis and compliance assuranceagencies in order for the administrative agency to evaluate theircompetency. Personnel matters are
5、 not highlighted in thisstandard since they are covered in detail in Specification E541.This is not meant to imply that they are not important.1.2 The preferred method for utilizing this practice is forqualified personnel of the administrative agency to visit thesystem analysis and compliance assura
6、nce agencies headquar-ters to speak to qualified personnel and examine pertinentrecords and documentation. Alternatively, the evaluation maybe done at any location provided the agency being evaluated isfully informed as to the material and personnel they will needto have on hand for the evaluation.1
7、.3 Some of the following will not be applicable in theevaluation of an agency that has not had prior experience as abuilding-evaluation organization. It is not the intent of thispractice to preclude acceptance of such an agency provided itcan otherwise demonstrate that its organizational proceduresa
8、nd experience in other product categories and experience ofkey personnel reflect a keen awareness of the problems andprocesses involved in manufactured building evaluation andthus warrant acceptance. In such instances the administrativeagency may wish to consider extending provisional acceptanceover
9、 a definite period of time, during which it is expected thatthe agency will have opportunity to gain the requisite experi-ence and demonstrate its capabilities and compliance assurancefunctions for manufactured building.1.4 Failure of an agency to respond satisfactorily to one ormore criteria in the
10、 following should not be sole cause forrejection. Such failure should be brought to the agencysattention and be subject to close scrutiny during subsequentreevaluations.1.5 This practice is intended to achieve uniformity in theregulation of manufactured building. It may be necessary tomake changes a
11、nd modifications in order to adapt to legislativeor other regulatory requirements of some jurisdictions.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and
12、health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E541 Specification for Agencies Engaged in System Analy-sis and Compliance Assurance for Manufactured Building3. System Analysis“6.2.1 Drawings, calculations, and speci
13、fications of manu-factured building shall be reviewed by agencys engineeringstaff and details compared with provisions of applicable1This practice is under the jurisdiction of ASTM Committee E36 on Accredi-tation & Certification and is the direct responsibility of Subcommittee E36.70 onAgencies Perf
14、orming Construction Inspection, Testing and Special Inspection.Current edition approved May 1, 2008. Published October 2008. Originallyapproved in 1978. Last previous edition approved in 2001 as E651 01. DOI:10.1520/E0651_E0651M-01R08.2In preparation of this practice, much assistance was gained by r
15、eferring toBuilding Science Series 87, “Model Documents for the Evaluation, Approval, andInspection of Manufactured Buildings,” prepared by the Center for BuildingTechnology, Institute for Applied Technology, National Bureau of Standards, issuedJuly 1976.3For referenced ASTM standards, visit the AST
16、M website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United
17、 StatesNOTICE: This standard has either been superseded and replaced by a new version or withdrawn.Contact ASTM International (www.astm.org) for the latest information1requirements. The construction of assemblies or components orboth, including material identification, shall be compared withpublishe
18、d descriptions of listed, approved, or recognized de-signs where applicable.”43.1 Questions:53.1.1 Does the system analysis agency have on hand copiesof the standard(s), codes(s), specification(s), etc., against whichthe product is being evaluated?3.1.2 Does the system analysis agency have on hand “
19、howto” manuals such as UPC Plumbing Code InterpretationsManual, NFPA Handbook of the National Electrical Code, etc.,and similar manuals which provide the agency with usefulbackground information? Does the agency maintain copies ofcurrent product directories, lists, certification directories, etc.,pu
20、blished or issued by independent organizations, tradeassociations, and other groups?3.1.3 Ask to see checklists and other evaluation aids devel-oped by the system analysis agency, or developed by othersand used by the agency, in their evaluation process. Does theagency have: (a) a data collection ch
21、ecklist for determining theadequacy of data submitted by the manufacturer for review(that is, how does the agency know when it has sufficient datato start a review?); (b) a comprehensive review checklist fordetermining compliance with applicable standards and proce-dures that cover the full range of
22、 architectural, structural,mechanical, etc., features to be reviewed? Does the reviewchecklist include provisions for convenient notation of thoseitems found to be and not to be in compliance with the code(s)?3.1.4 Ask the system analysis agency to explain the criteriaupon which they base their acce
23、ptance or rejection of acomponent, material, device, etc., used in the building system.3.1.4.1 Is the product specifically identified as to make,model, type designation, etc.?3.1.4.2 Is the code or standard that forms the technical basisfor certification of a product known, such as by being markedon
24、 the product, or included in the certifiers seal, label, or mark,or referenced in the certifiers test report or other availabledocuments?3.1.5 Ask the system analysis agency to explain the criteriaupon which they base their acceptance or rejection of tests onindividual products used in the building
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM E651 E651M 01 2008 Standard Practice for Evaluating Capabilities of Agencies Involved in System Analysis and Compliance Assurance Manufactured Building Withdrawn 2017

链接地址:http://www.mydoc123.com/p-287133.html