《ASTM B868 - 96(2013) Standard Practice for Contact Performance Classification of Electrical Connection Systems (Withdrawn 2017).pdf》由会员分享,可在线阅读,更多相关《ASTM B868 - 96(2013) Standard Practice for Contact Performance Classification of Electrical Connection Systems (Withdrawn 2017).pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B868 96 (Reapproved 2013)Standard Practice forContact Performance Classification of Electrical ConnectionSystems1This standard is issued under the fixed designation B868; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides a uniform method of specifyingperformance requirements for (or reporting test resu
3、lts of)electrical contact and connection systems. Both conductor andconnector system performance may be specified by thispractice, separately or in combination.1.2 This practice may be used for separable or permanentcontacts employing metallic conductors and contacts.1.3 This practice provides metho
4、ds for both signal andpower applications.1.4 This practice does not specify the sample preparation ortest sequences required for determining contact performance. Itis the responsibility of the user of this practice to determine theapplied test sequence(s) appropriate for the application.1.5 This sta
5、ndard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to become familiarwith all hazards including those identified in the appropriateMaterial Safety Data Sheet (MSDS) for this product/materialas provided by
6、 the manufacturer, to establish appropriatesafety and health practices, and determine the applicability ofregulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B539 Test Methods for Measuring Resistance of ElectricalConnections (Static Contacts)B542 Terminology Relating to E
7、lectrical Contacts and TheirUseB812 Test Method for Resistance to Environmental Degra-dation of Electrical Pressure Connections Involving Alu-minum and Intended for Residential Applications2.2 UL Standard:UL 486B Wire Connectors for Use with AluminumConductors, Third Edition, 199133. Terminology3.1
8、Terms used in this practice are defined in TerminologyB542 except as noted in 3.2.3.2 Definitions of Terms Specific to This Standard:3.2.1 conductor, nelectrically conductive member carry-ing current to a contact interface. Examples are wire and cable,busbar, and conductive paths on an etched printe
9、d circuitboard.3.2.2 contact performance, ncontact interface behavior asindicated by initial electrical resistance and resistance changeunder the applied test conditions.4. Summary of Practice4.1 The prescribed performance specification (or reporting)statement consists of three sections, as follows:
10、4.1.1 Performance Classification, in accordance with thispractice (Section 6).4.1.2 Variability Index, determined by sample size anddistribution of resistance values measured at end of test, inaccordance with this practice (Section 7).4.1.3 Statement of test method employed to determineperformance c
11、lassification.4.2 The format for the performance specification (or report-ing) statement is as follows:1This practice is under the jurisdiction ofASTM Committee B02 on NonferrousMetals and Alloys and is the direct responsibility of Subcommittee B02.11 onElectrical Contact Test Methods.Current editio
12、n approved Oct. 1, 2013. Published October 2013. Originallyapproved in 1996. Last previous edition approved in 2008 as B868 96 (2008).DOI: 10.1520/B0868-96R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of
13、ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Underwriters Laboratories (UL), 333 Pfingsten Rd.,Northbrook, IL 60062-2096, http:/.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Un
14、ited StatesNOTICE: This standard has either been superseded and replaced by a new version or withdrawn.Contact ASTM International (www.astm.org) for the latest information15. Significance and Use5.1 This practice is based on the use of electrical resistanceas an indicator of contact performance.5.2
15、Existing standards, such as those referenced in Section 2as representative examples, provide the basis for applied testconditions. Modifications in procedure or sample size, or both,of existing standards may have to be made to provide forresistance measurement and to meet variability index require-m
16、ents that a user may specify.5.3 This practice accommodates the use of multiple testmethods, as may be required to assure satisfactory performancein a given application.6. Performance Classification6.1 The performance classification statement consists ofthree letters in sequence indicating, respecti
17、vely, category ofcontact (signal or power), average initial contact resistance,and change of average contact resistance as a consequence ofthe applied test conditions.6.2 For this standard classification method, the performanceof a connection system for power applications is expressed asthe ratio of
18、 the contact resistance to the equivalent resistance ofthe attached conductor. The equivalent resistance of the con-ductor is the resistance of a length of solid circular conductorexactly one diameter in length. The conductor size used for theevaluation shall be that which is normally specified or u
19、tilizedwith the particular connection system being evaluated.6.2.1 For connection systems involving solid circularconductors, the equivalent resistance Rdis calculated accord-ing to the formula:Rd5 R 3 Dwhere:Rd= equivalent resistance,R = resistance per unit length, , andD = diameter of conductor (i
20、n same length unit).6.2.1.1 Appendix X1 provides representative nominal datafor some common sizes of copper and aluminum conductors ofcircular cross section for the purpose of establishing instru-mentation requirements.6.2.2 For conductors with other than solid circular crosssection, equivalent diam
21、eter based on actual conductive cross-section area shall be used. For example: a conductor ofrectangular cross section 0.5 by 6 mm has a cross-section areaequal to that of a solid circular conductor 1.95 mm in diameter,and therefore D in the equation in 6.2.1 is 1.95 mm.6.2.3 For contacts incorporat
22、ing or connecting conductorsof different materials or cross section, or both, the Rdvalueused for contact performance determination shall be based onthe conductor of minimum resistance per unit length.6.2.4 For contacts involving a connector, the conductormaterial and cross section used for determin
23、ation of the Rdvalue to be used shall be the wire, busbar, circuit boardconductive strip, or other, as appropriate for the rating orrepresentative application of the connector. The conductor sizemay be determined according to the connector manufacturersspecification, current rating, or conventional
24、application prac-tice.6.2.5 Conductor resistance per unit length is preferablydetermined by measurements incorporating the same instru-mentation used for contact resistance measurements, at thesame ambient temperature and current as for the contactperformance test being applied.6.2.6 When conductor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM B868 96 2013 Standard Practice for Contact Performance Classification of Electrical Connection Systems Withdrawn 2017

链接地址:http://www.mydoc123.com/p-286725.html