ASTM C279-17 Standard Specification for Chemical-Resistant Masonry Units.pdf
《ASTM C279-17 Standard Specification for Chemical-Resistant Masonry Units.pdf》由会员分享,可在线阅读,更多相关《ASTM C279-17 Standard Specification for Chemical-Resistant Masonry Units.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C279 17Standard Specification forChemical-Resistant Masonry Units1This standard is issued under the fixed designation C279; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenth
2、eses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers solid, kiln fired brick and tilemade from clay, shale, or mixtures thereof, suitable for indoorand outdoor use in masonry con
3、struction subjected to chemicalenvironments (see Terminology C1232).1.2 The brick and tile covered herein are intended for use inchemical environments where resistance to thermal shock maybe a consideration. The brick and tile are normally used withchemical-resistant mortars.1.3 The values stated in
4、 inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
5、is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization
6、established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C20 Test Methods for Apparent Porosity, Water Absorption,A
7、pparent Specific Gravity, and Bulk Density of BurnedRefractory Brick and Shapes by Boiling WaterC67 Test Methods for Sampling and Testing Brick andStructural Clay TileC1232 Terminology of MasonryE11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Terminology3.1 DefinitionsFor definiti
8、ons relating to chemical-resistant masonry units, refer to Terminology C1232.4. Classification4.1 The physical and chemical properties of brick and tilediffer from supplier to supplier, mainly because their compo-sition is determined by the source of raw materials. Regardlessof the differences, bric
9、k and tile are considered to be one ofthree types and one of two classes as follows:4.1.1 Type IFor use where low absorption and high acidresistance are not major factors.4.1.2 Type IIFor use where lower absorption and higheracid resistance are required.4.1.3 Type IIIFor use where minimum absorption
10、 andmaximum acid resistance are required.NOTE 1Types I, II, and III may not differ significantly in thermalshock resistance. The suitability of a given brick, for a particularapplication should be determined at the time of purchase by agreementbetween the purchaser and the supplier.NOTE 2Types I and
11、 III were formerly designated Type “H” and “L”respectively.4.1.4 Class SFor use in standard applications.4.1.5 Class XFor use where a higher degree of precisionand lower permissible variation in size than that permitted forClass S is required.5. Physical Properties5.1 StrengthThe brick and tile when
12、 tested in accordancewith Test Methods C67 shall conform to the requirements formodulus of rupture (flexural strength) for the type specified, asprescribed in Table 1.5.2 Water AbsorptionThe brick and tile when tested inaccordance with Test Methods C20 shall conform to therequirements for water abso
13、rption (based on the 2 h boil) forthe type specified, as prescribed in Table 1.6. Dimensions and Permissible Variations6.1 SizesThe sizes of the brick and tile shall be asspecified by the purchaser. The length, width, and depth1This specification is under the jurisdiction of ASTM Committee C15 onMan
14、ufactured Masonry Units and is the direct responsibility of SubcommitteeC15.02 on Brick and Structural Clay Tile.Current edition approved June 1, 2017. Published July 2017. Originally approvedin 1951. Last previous edition approved in 2013 as C279 13a. DOI: 10.1520/C0279-17.2For referenced ASTM stan
15、dards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM Intern
16、ational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, G
17、uides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1Mon Apr 30 39 measurements of the brick or tile shall be within 63 % of thespecified dimensions for Class S units and within 61.5 % ofthe specified dimensions for Class X units.6.2 WarpageTh
18、e brick and tile shall conform to therequirements as shown in Table 2.7. Finish and Appearance7.1 Surface TexturesBrick or tile surfaces are often tex-tured in order to promote better bonding. Texturing is accom-plished by scoring, wire cutting, matting, or other meansconsistent with a manufacturers
19、 process. If texturing is done,the protrusion or indentation shall not exceed18 in. (3 mm) indepth.7.2 The brick and tile shall be free of open surface lamina-tions or cracks which would impair the performance of theconstruction.NOTE 3Open laminations or cracks within the brick or tile observedin th
20、e brick or tile cut or broken during testing, should be noted with theirsize and number indicated as part of the test report. If internal openlaminations or cracks, or both, are reported, the purchaser shall determinethe suitability of such brick or tile for his application.7.3 Black HeartBrick or t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM C279 17 Standard Specification for Chemical Resistant Masonry Units

链接地址:http://www.mydoc123.com/p-286598.html