HD 620 S1 VOL 1-1996 Distribution Cables with Extruded Insulation for Rated Voltages from 3 6 6 (7 2) kV to 20 8 36 (42) kV (Volume 1 Parts 1 to 5)《额定电压3 6 6(7 .pdf
《HD 620 S1 VOL 1-1996 Distribution Cables with Extruded Insulation for Rated Voltages from 3 6 6 (7 2) kV to 20 8 36 (42) kV (Volume 1 Parts 1 to 5)《额定电压3 6 6(7 .pdf》由会员分享,可在线阅读,更多相关《HD 620 S1 VOL 1-1996 Distribution Cables with Extruded Insulation for Rated Voltages from 3 6 6 (7 2) kV to 20 8 36 (42) kV (Volume 1 Parts 1 to 5)《额定电压3 6 6(7 .pdf(703页珍藏版)》请在麦多课文档分享上搜索。
1、STD.CENELEC HD bSO SL-ENGL Lb ei 3404583 0190175 534 m HARMONIZATION DOCUMENT HD 620 SI DOCUMENT DHARMONISATION (Volume I: Parts 1 to 5) . HARMONISIERUNGSDOKUMENT June 1996 ICs 29.060.20 Descriptors: Electric cable, insulated cable. polyvinyl chloride, polyethylene, designation, composition, dimensi
2、on, construction characteristics, mechanical characteristics, test, marking English version Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV Cbles de distribution, isolation extrude, pour des tensions assignes de 3,6/6 (7,Z) kV 20,8/36 (42) kV in
3、clus Energieverteilungskabel mit extrudierter Isolierung fr Nennspannungen von 3,6/6 (7,2) kV bis 20,8/36 (42) kV This Harmonization Document was approved by CENELEC on 1995-1 1-28. CENELEC members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for implem
4、entation of this Harmonization Document on a national level. Up-to-date lists and bibliographical references concerning such national implementation may be obtained on application to the Central Secretariat or to any CENELEC member. This Harmonization Document exists in three official versions (Engl
5、ish, French, German). CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electro
6、technical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Centrai Secretariat: rue de Stassart 35, B - 1050 Brussels o 1996 Copyright reserved to CENELEC member. Ref. No. WD 620 S1:1996 E STD=CENELEC HD b20 SL-ENGL 199b 3404583 OL90L7b
7、 450 m Page 0-2 HD 620 S1:1996 FOREWORD This Harmonisation Document was prepared by WG9 of CENELEC Technical Committee TC20, Electric Cables. It was agreed by TC20 at its Helsinki meeting (May 1994) to be submitted for formal vote by National Committees. The document contains the following Parts, ar
8、ranged according to the main constructional features of the cables covered: Part 1 - Part 3 - Part 4 - Part 5 - Part 6 - Part 7 - Part 8 - Part 9 - General requirements PVC insulated single core cables PVC insulated three core cables XLPE insulated single core cables, and single core pre-assembled c
9、ables XLPE insulated three core cables EPR insulated single core cables and single core pre-assembled cables EPR insulated three core cables HEPR insulated single core cables, and single core pre-assembled cables There is no Part 2, which was to have covered Additional Test Methods. These have been
10、combined with the corresponding Part from HD 622 (Power cables having rated voltage from 3.6/6(7.2)kV up to and including 20.8/36(42)kV with special fire performance for use in power stations) to form Amendment No. 1 to HD 605. Each of Parts 3-9 inclusive are further divided into particular sections
11、 and, by decision of the Technical Board (D68/047) National Committees need at present only implement in their national language those sections having national applicability. The obligation remains however to announce the full HD in public by titles and numbers, and also to withdraw any conflicting
12、national standards. Page numbering reflects the arrangement into Parts and particular sections, e.g. Page 442-3 is page 3 of particular section C of Part 4. References to other HDs, ENS and international standards are given in the particular parts or sections. The draft was submitted to the formal v
13、ote and was approved by CENELEC as HD 620 S1 on 1995-1 1-28. The following dates were fixed: - latest date by which the existance of the HD has to be announced at national level (doa) 1996-06-01 latest date by which the HD has to be implemented at national level by publication of a harmonized nation
14、al standard or by endorsement (dop) 1996-1 2-01 latest date by which the national standards conflicting with the HD have to be withdrawn (daw) 1996-1 2-01 STD.CENELEC HD 620 SL-ENGL L99b 3404583 OL90L77 397 111 Page 0-3 HD 620 S1:1996 CONTENTS Volume I PART 1 General reauirements PART 3 PVC insulate
15、d sinale core cables 3-A 3-C Cables with PVC sheath (Type 3A Cables with PVC sheath (Type 3C) PART 4 PVC insulated three core cables 4-A 4-C Cables with PVC sheath (Type 4A) Cables with PVC sheath (Type 4C) PART 5 XLPE insulated sinale core cables, and sinale core ore-assembled cables 5-A 5-B 5-c 5-
16、D 5-E-1 5-E-2 5-F 5-G 5-H 5-J 5-K 5-L 5-M 5-N 5-0-1 5-0-2 5-0-3 5-0-4 5-0-5 5-0-6 5-P Cables with PE (Type 5A-1) or PVC sheath (Type 5A-2) Cables with PE (Type 5B-1) or PVC sheath (Type 58-21 Cables with PE (Type 5C-1) or PVC sheath (Type 5C-2) Cables with PE (Type 5D-1) or PVC sheath (Type 5D-2) Ca
17、bles with PVC sheath (Type 5E-1) or PVC separation sheath and PVC outer sheath (Type 5E-2) Bundle assembled cables with steel messenger core for overhead distribution and service MV (Type 5E-3) Cables with aluminium conductors and PVC sheath (Type 5F-1 1, cables with aluminium conductors and PE shea
18、th, laid-up (Type 5F-21, cables with aluminium conductors and PE sheath, laid-up around a bare earth conductor (Type 5F-31, cables with aluminium conductors and PE sheath, laid-up around a steel messenger (Type 5F-4) and cables with copper conductors and PVC sheath (Type 5F-5) Cables with PVC sheath
19、 laid-up (Type 5G-11, cables with PVC sheath laid-up around an earth conductor (Type 5G-2 end Type 5G-31, cables with PVC sheath laid around a messenger (Type 5G-4) and cables with PVC sheath not laid-up (Type 5G-5) Cables with PE sheath (Type 5H) Cables with PE (Type 5J-11 or PVC sheath (Type 5J-2)
20、 or PVC flame retardant sheath (Type 5J-31 Cables with PE (Type 5K-1) or PVC sheath (Type 5K-2) Cables with PVC sheath, laid-up (Type 5L-1) or not (Type 5L-2) around an additional conductor Cables with PE sheath (Type 5M-1) and PVC sheath (Type 5M-2) Cables with PE sheath (Type 5N-1) or PVC sheath (
21、Type 5N-2) Single core XLPE insulated cables (Type 50-1) Single core XLPE insulated cables with lead sheath (Type 50-2) XLPE insulated Triplex cables with PE sheath (Type 50-3) Single core XLPE insulated cables with wire screens and PE sheath (Type 50-4) Cables with alternative wire screens and PE s
22、heath (Type 50-5) Single core XLPE insulated cables with wire screens and PVC sheath (Type 50-6) Cables with PVC sheath laid-up around an earth conductor (Type 5P-1 and Type 5P-2), cables with PVC sheath laid around a messenger (Type 5P-3) STD.CENELEC HD 620 SL-ENGL L77b 3404583 0170178 223 Page 0-4
23、 HD 620 S 1 :I 996 CONTENTS Volume II PART 6 XLPE insulated three core cables 6-A 6-C 6-D 6-F 6- J 6-K 6-M 6-N 6-0-1 6-0-2 6-0-3 Cables with PE (Type 6A-1) or PVC sheath (Type 6A-2) Cables with PE (Type 6C-1) or PVC sheath (Type 6C-2) Cables with PE (Type 6D-1) or PVC (Type 60-2) sheath Cables with
24、PVC sheath and individual copper screen (Type 6F-11, cables with PE sheath and individual copper screen (Type 6F-2) and cables with PE sheath and common copper screen (Type 6F-3) Cables with PE (Type 6J-1) or PVC sheath (Type 6J-21 or PVC flame retardant sheth (Type 6J-3) Cables with PE (Type 6K-1)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HD620S1VOL11996DISTRIBUTIONCABLESWITHEXTRUDEDINSULATIONFORRATEDVOLTAGESFROM36672KVTO2083642KVVOLUME1PARTS1TO5

链接地址:http://www.mydoc123.com/p-1341453.html