1、 Reference number ISO 7240-11:2011(E) ISO 2011INTERNATIONAL STANDARD ISO 7240-11 Second edition 2011-06-15 Fire detection and alarm systems Part 11: Manual call points Systmes de dtection et dalarme dincendie Partie 11: Dclencheurs manuels dalarme ISO 7240-11:2011(E) COPYRIGHT PROTECTED DOCUMENT ISO
2、 2011 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the
3、country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2011 All rights reservedISO 7240-11:2011(E) ISO 2011 All rights reserved iiiContents Page Foreword iv
4、Introductionvi 1 Scope1 2 Normative references1 3 Terms and definitions .2 4 Requirements.3 4.1 Compliance 3 4.2 Marking and data .3 4.3 Frangible element4 4.4 Indicators for alarm condition5 4.5 Reset facility 5 4.6 Test facility.5 4.7 Construction and design 5 4.8 Requirements for software control
5、led manual call points10 5 Tests .12 5.1 General .12 5.2 Operational performance14 5.3 Function test 16 5.4 Test facility test (operational) 16 5.5 Reliability (endurance)17 5.6 Variation of supply parameters17 5.7 Dry heat (operational) .18 5.8 Dry heat (endurance).19 5.9 Cold (operational)20 5.10
6、Damp heat, cyclic (operational) .21 5.11 Damp heat, cyclic (endurance) 22 5.12 Damp heat, steady state (endurance)22 5.13 SO 2corrosion (endurance) 23 5.14 Shock (operational) .24 5.15 Impact (operational) 25 5.16 Vibration, sinusoidal (operational) 26 5.17 Vibration, sinusoidal (endurance) .27 5.18
7、 Electromagnetic compatibility (EMC) (operational).28 5.19 Enclosure protection.29 5.20 Exposure to simulated solar radiation (endurance) 30 6 Test report31 Annex A (normative) Test apparatus for test of operation.32 Annex B (informative) Test apparatus for test for non-operation34 Annex C (informat
8、ive) Apparatus for impact test 35 Bibliography39 ISO 7240-11:2011(E) iv ISO 2011 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally
9、carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the wo
10、rk. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare Inte
11、rnational Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of t
12、he elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 7240-11 was prepared by Technical Committee ISO/TC 21, Equipment for fire protection and fire fighting, Subcommittee SC 3, Fire detection and alarm s
13、ystems. This second edition cancels and replaces the first edition (ISO 7240-11:2005), which has been technically revised. It also incorporates the Amendment ISO 7240-11:2005/Amd.1:2009. ISO 7240 consists of the following parts, under the general title Fire detection and alarm systems: Part 1: Gener
14、al and definitions Part 2: Control and indicating equipment Part 3: Audible alarm devices Part 4: Power supply equipment Part 5: Point-type heat detectors Part 6: Carbon monoxide fire detectors using electro-chemical cells Part 7: Point-type smoke detectors using scattered light, transmitted light o
15、r ionization Part 8: Carbon monoxide fire detectors using an electro-chemical cell in combination with a heat sensor Part 9: Test fires for fire detectors Technical Specification Part 10: Point-type flame detectors Part 11: Manual call points Part 12: Line type smoke detectors using a transmitted op
16、tical beam Part 13: Compatibility assessment of system components ISO 7240-11:2011(E) ISO 2011 All rights reserved v Part 14: Guidelines for drafting codes of practice for design, installation and use of fire detection and fire alarm systems in and around buildings Technical Report Part 15: Point ty
17、pe fire detectors using scattered light, transmitted light or ionization sensors in combination with a heat sensor Part 16: Sound system control and indicating equipment Part 17: Short-circuit isolators Part 18: Input/output devices Part 19: Design, installation, commissioning and service of sound s
18、ystems for emergency purposes Part 20: Aspirating smoke detectors Part 21: Routing equipment Part 22: Smoke-detection equipment for ducts Part 24: Sound-system loudspeakers Part 25: Components using radio transmission paths Part 27: Point-type fire detectors using a scattered-light, transmitted-ligh
19、t or ionization smoke sensor, an electrochemical-cell carbon-monoxide sensor and a heat sensor Part 28: Fire protection control equipment A part 23 dealing with visual alarm devices and a part 29 dealing with video fire detectors are under development. ISO 7240-11:2011(E) vi ISO 2011 All rights rese
20、rvedIntroduction This part of ISO 7240 has been prepared by ISO/TC 21/SC 3, the secretariat of which is held by SA and is based on ISO 7240-11:2005. This part of ISO 7240 has been drafted on the basis of appearance and functions that should be provided on all manual call points for use in fire detec
21、tion and fire alarm systems. The colours, dimensions, shapes and methods of operation are based on recognized operating principles that give confidence and recognition to the user when operating in genuine fire alarm situations. The purpose of a manual call point is to enable a person discovering a
22、fire to initiate the operation of a fire alarm system so that appropriate measures can be taken. It is important for manual call points to be recognizable and simple to use, without the requirement to read elaborate instructions so that anyone discovering a fire is able to use the manual call point
23、without previous familiarity with it. The intention of this part of ISO 7240 is to specify requirements for operation and reliability. The methods of operation of the manual call points covered are as follows: type A: direct operation (single action); type B: indirect operation (double action). Both
24、 types require the breaking or the visible displacement by change of the position of a frangible element forming part of the front face, which is considered as the most suitable method for general application and which acts as a deterrent to the misuse of the device. Importance has been placed on id
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO7240112011FIREDETECTIONANDALARMSYSTEMSPART11MANUALCALLPOINTS 火灾 探测 报警 系统 11 部分 人工 PDF

链接地址:http://www.mydoc123.com/p-1255234.html