ISO 12949-2011 Standard test method for measuring the heat release rate of low flammability mattresses and mattress sets《低可燃性床垫和床垫套件放热率测量用标准试验法》.pdf
《ISO 12949-2011 Standard test method for measuring the heat release rate of low flammability mattresses and mattress sets《低可燃性床垫和床垫套件放热率测量用标准试验法》.pdf》由会员分享,可在线阅读,更多相关《ISO 12949-2011 Standard test method for measuring the heat release rate of low flammability mattresses and mattress sets《低可燃性床垫和床垫套件放热率测量用标准试验法》.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、Standard test method for measuring the heat release rate of low flammability mattresses and mattress sets Mthode dessai normalise pour mesurer le dbit calorifique de matelas et dlments de matelas inflammabilit rduite ISO 2011 Reference number ISO 12949:2011(E) First edition 2011-11-01 ISO 12949 INTE
2、RNATIONAL STANDARDISO 12949:2011(E)COPYRIGHT PROTECTED DOCUMENT ISO 2011 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writi
3、ng from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2011 All rights reservedISO 12949:2
4、011(E) ISO 2011 All rights reserved iii Contents Page Foreword . v Introduction .vi 1 Scope 1 2 Normative references . 1 3 Terms and definitions . 1 4 Summary of test method . 2 5 Significance and use 2 6 Apparatus and equipment . 2 6.1 Test area . 2 6.2 Test frame 5 6.3 Ignition source . 6 6.4 Fuel
5、 supply and control .10 6.5 Ignition burner gas flow . 11 7 Test specimens 12 8 Test preparation .12 8.1 Specimen conditioning 12 8.2 Instrument calibration 13 8.3 Specimen orientation .13 8.4 Burner set-up 13 8.5 Burner alignment procedure 14 8.6 Video recording 17 9 Test procedure .18 9.1 Safety p
6、recautions 18 9.2 Burner preparation 18 9.3 Initiation of recording systems 18 9.4 Test initiation 18 9.5 Test conduct .19 10 Test report .19 Annex A (informative) Reducing fire hazards associated with mattress flammability 21 Bibliography .23Foreword ISO (the International Organization for Standard
7、ization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to
8、be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Stand
9、ards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an Inte
10、rnational Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 12949
11、was prepared by Technical Committee ISO/TC 92, Fire safety, Subcommittee SC 1, Fire initiation and growth. ISO 12949:2011(E)iv ISO 2011 All rights reservedIntroduction A typical bed consists of several components, including a mattress, a foundation, and a collection of bedclothes (e.g. mattress pad,
12、 sheets, pillows, blankets, quilts and/or comforters). Mattress and bedding fires are a major contributor to residential fire deaths 1 . A significant portion of these deaths and injuries results from fires in which the bedclothes are the first items ignited, and those flames ignite the mattress or
13、foundation. In the United States, approximately two-thirds of all deaths from flaming bed fires occur after the room has reached the point of flashover 2 . This accounts for nearly all the fatalities that occur outside the room of fire origin and about half of the fatalities that occur within the ro
14、om of origin. A burning mattress is generally the primary energy contributor to a fatal bedroom fire. Once the mattress is ignited, the fire develops rapidly. Room flashover occurs at heat release rates near or above 1 000 kW (1 MW) for small-to-medium size bedrooms 3 . 1 m wide mattresses, without
15、bedclothes, have been shown to reach peak heat release rates of 2 MW and flash over a room in less than 300 s 3 . In addition, a typical set of bedclothes on a 1 m wide bed can lead to a fire whose peak rate of heat release is approximately 100 kW to 200 kW 4 , with values up to 400 kW possible for
16、the heaviest sets 5 . A bed clothes fire can become appreciably more threatening on larger beds 6 . It follows that a significant reduction in bed fire fatalities can be achieved by reducing the combined peak heat release rate of a bed, the bedclothes, and other furnishings ignited by the bedclothes
17、 to a level well below 1 MW. Current regulation in the United States limits the peak rate of heat release of a mattress and foundation to 200 kW and the total heat release to 15 MJ during the first 10 min of the test 7, 8 . Combined with the typical heat release rate of the bedclothes, which general
18、ly occurs well before the peak heat release from the mattress, the overall heat release rate from the burning bed is substantially below the value that leads to room flashover. Furthermore, as the intensity of the bed fire is decreased this much, there is an accompanying reduction in the spatial ext
19、ent of the radiant heat from flames. This reduces the likelihood that other bedroom furnishings will be ignited by the bed fire and greatly increases the time available for occupants to recognize and escape the fire. This International Standard addresses a fire hazard scenario different from one in
20、which a cigarette ignites the bed and threatens people who might be asleep on the bed with their heads near the location of the dropped cigarette. The resulting deaths most often result from inhalation of the toxic fumes from the smouldering fire and are distinct from the deaths that are to be avert
21、ed by limiting the flaming intensity of the bed fire. In several countries, mattresses are tested for cigarette ignition resistance 9 , which reduces the likelihood of smouldering fires, but infrequently addresses the fire hazard addressed by this International Standard. ISO 12949:2011(E) ISO 2011 A
22、ll rights reserved vINTERNATIONAL STANDARD ISO 12949:2011(E) Standard test method for measuring the heat release rate of low flammability mattresses and mattress sets WARNING So that suitable precautions can be taken to safeguard health, the attention of all concerned with fire tests is drawn to the
23、 possibility that toxic or harmful gases are evolved during combustion of test specimens. The test procedures involve high temperatures. Hazards can therefore exist for burns and ignition of extraneous objects or clothing. The operators should use protective clothing, helmets, face-shields, and brea
24、thing equipment for avoiding exposure to toxic gases. Laboratory safety procedures should be set up to ensure the safe termination of tests. It is imperative that adequate means of extinguishing such a fire are provided. 1 Scope This International Standard provides a full-scale test method for deter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO129492011STANDARDTESTMETHODFORMEASURINGTHEHEATRELEASERATEOFLOWFLAMMABILITYMATTRESSESANDMATTRESSSETS

链接地址:http://www.mydoc123.com/p-1250616.html