ASTM D7192-2018 Standard Test Method for High Speed Puncture Properties of Plastic Films Using Load and Displacement Sensors.pdf
《ASTM D7192-2018 Standard Test Method for High Speed Puncture Properties of Plastic Films Using Load and Displacement Sensors.pdf》由会员分享,可在线阅读,更多相关《ASTM D7192-2018 Standard Test Method for High Speed Puncture Properties of Plastic Films Using Load and Displacement Sensors.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7192 10D7192 18Standard Test Method forHigh Speed Puncture Properties of Plastic Films Using Loadand Displacement Sensors1This standard is issued under the fixed designation D7192; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of puncture properties of plastic films, over a ran
3、ge of test velocities.1.1.1 Test Method ASTM Terminology Standard D1004D883 has defined film as having a thickness not greater than 0.25 mm.Plastic materials having a thickness above this limit are not to be excluded from use unless shown to be rigid (see 3.2.1). TestMethod D3763 is the recommended
4、method for instrumented puncture testing of rigid plastics.1.2 Test data obtained by this test method is relevant and appropriate for use in engineering design.1.3 The values stated in SI units are to be regarded as standard.1.4 This standard does not purport to address all of the safety concerns, i
5、f any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.NOTE 1This test method does not closely conform to ISO 7765-2.
6、The only similarity between the two tests is that they are both instrumented impacttests. The differences in striker, fixture, specimen geometries and in test velocity can produce significantly different test results.NOTE 1This test method does not closely conform to ISO 7765-2. The only similarity
7、between the two tests is that they are both instrumented impacttests. The differences in striker, fixture, specimen geometries and in test velocity can produce significantly different test results.1.5 This international standard was developed in accordance with internationally recognized principles
8、on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics
9、for TestingD883 Terminology Relating to PlasticsD1004 Test Method for Tear Resistance (Graves Tear) of Plastic Film and SheetingD1600 Terminology for Abbreviated Terms Relating to PlasticsD3763 Test Method for High Speed Puncture Properties of Plastics Using Load and Displacement SensorsD4000 Classi
10、fication System for Specifying Plastic MaterialsD6988 Guide for Determination of Thickness of Plastic Film Test Specimens3. Terminology3.1 DefinitionsFor definitions see Terminology D883 and for abbreviations, see Terminology D1600.3.2 Definitions of Terms Specific to This Standard:3.2.1 rigid, adja
11、ny plastic specimen that, when placed on the support component of the open clamp assembly, does not deflectinto the center of the unsupported region (under its own weight) by more than 0.05 mm from the horizontal plane of the supportcomponent.1 This test method is under the jurisdiction of ASTM Comm
12、ittee D20 on Plastics and is the direct responsibility of Subcommittee D20.19 on Film, Sheeting, and MoldedProducts.Current edition approved April 1, 2010Nov. 1, 2018. Published May 2010November 2018. Originally approved in 2005. Last previous edition approved in 20082010 asD7192 - 08a.D7192 - 10. D
13、OI: 10.1520/D7192-10.10.1520/D7192-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an
14、 ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. I
15、n all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.1.
16、1 DiscussionThis definition is provided as a guideline to allow testing of soft, pliable plastic materials that are thicker than 0.25 mm.4. Significance and Use4.1 This test method is designed to provide load versus deformation response of plastic films under essentially multi-axialdeformation condi
17、tions at impact velocities. This test method further provides a measure of the rate sensitivity of the plastic filmsto impact.4.2 Multi-axial impact response, while partly dependent on thickness, does not necessarily have a linear correlation withspecimen thickness. Therefore, results should be comp
18、ared only for specimens of essentially the same thickness, unless specificresponses versus thickness formulae have been established for the plastic films being tested.4.3 For many plastic films, there may be it is possible that a specification exists that requires the use of this test method, butwit
19、h some procedural modifications that take precedence when adhering to the specification. Therefore, it is advisable to refer tothat material specification before using this test method. Table 1 of Classification System D4000 lists the ASTM materialsstandards that currently exist.4.4 The values obtai
20、ned by this test method are highly dependent on the method and conditions of film fabrication as well asthe type and grade of resin. Results can vary significantly, depending upon sample quality, uniformity of film gage, die marks,contaminants, and so forth.5. Apparatus5.1 The testing machine shall
21、consist of two assemblies, one fixed and the other driven by a suitable method to achieve therequired impact velocity (that is, hydraulic, pneumatic, mechanical, or gravity):5.1.1 Specimen Clamp AssemblyThis device shall be permitted to be variable with respect to the holding of the specimenmaterial
22、, depending upon specimen characteristics. The unsupported region of the specimen clamp assembly shall have a diameterof 76 6 3.0 mm. The edges of the unsupported region shall be rounded to a radius of 0.8 6 0.4 mm. The holding techniqueemployed on the specimen must not interfere with the radius edg
23、e of the clamp assembly. Specimens should be held taut but notstretched so as to cause damage to the specimen prior to test.NOTE 2The following techniques have been successfully employed for different types of plastic films: Parallel rigid plates clamped together with sufficient force (mechanically,
24、 pneumatically or hydraulically) to prevent slippage of the specimen in theclamp during impact. Rubber-like gaskets or o-rings affixed to the rigid plates to provide cushioning or gripping of the specimen when clamping force is applied. Removable assemblies, consisting of two concentric rings (one s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD71922018STANDARDTESTMETHODFORHIGHSPEEDPUNCTUREPROPERTIESOFPLASTICFILMSUSINGLOADANDDISPLACEMENTSENSORSPDF

链接地址:http://www.mydoc123.com/p-1243729.html