《UL SUBJECT 283A-2011 OUTLINE OF INVESTIGATION FOR AFTER-MARKET REFILLS FOR USE WITH SPECIFIC MANUFACTURER S LISTED DEODORIZER OR AIR FRESHENER (Issue 1)《与特定制造商的上市除臭剂或者空气清新剂一起使用的后市场.pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 283A-2011 OUTLINE OF INVESTIGATION FOR AFTER-MARKET REFILLS FOR USE WITH SPECIFIC MANUFACTURER S LISTED DEODORIZER OR AIR FRESHENER (Issue 1)《与特定制造商的上市除臭剂或者空气清新剂一起使用的后市场.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFebruary 11, 20111SUBJECT 283AOUTLINE OF INVESTIGATIONFORAFTER-MARKET REFILLS FOR USE WITH SPECIFIC MANUFACTURERSLISTED DEODORIZER OR AIR FRESHENERISSUE NO: 1February 11, 2011Summary of TopicsThi
2、s first issue of the Outline of Investigation for After-Market Refills ForUse With Specific Manufacturers Listed Deodorizer Or Air Freshener,Subject 283A, applies to after-market refills intended for consumerinstallation into electric deodorizer or air freshener appliances.COPYRIGHT 2011 UNDERWRITER
3、S LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFEBRUARY 11, 2011SUBJECT 283A2No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1
4、 Scope .42 General 43 Glossary .4CONSTRUCTION4 General 4PERFORMANCE5 General 56 After-market Refill Retention Test .5MARKINGS7 General 6INSTRUCTIONS8 General 7FEBRUARY 11, 2011 SUBJECT 283A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTR
5、ODUCTION1 Scope1.1 These requirements cover after-market refills (see 3.1) intended for consumer installation into electricdeodorizer or air freshener appliances.1.2 These requirements do not cover after-market refills requiring pouring by the user.2 General2.1 In addition to complying with Sections
6、38ofthese requirements, the after-market refill, alone andin combination with the appliance shall comply with the applicable requirements of the Standard for AirFresheners and Deodorizers, UL 283.3 Glossary3.1 AFTER-MARKET REFILL A consumable scent replacement for consumer installation into one ormo
7、re specific deodorizer or air freshener appliances. After-market refills are not integrally packaged orbundled with the appliance. They shall be one of the following types:a) Non-refillable gel pack, or;b) Non-refillable liquid consumables in either thermoplastic or glass containers.CONSTRUCTION4 Ge
8、neral4.1 The after-market refill shall be formed and assembled so that it may be installed, in accordance withthe user installation instructions, into its specified air freshener or deodorizer, without risk of fire or electricshock. Risk of fire or electric shock is determined by compliance with the
9、 construction and performancerequirements herein and the applicable requirements of the Standard for Air Fresheners and Deodorizers,UL 283.4.2 If the after-market refill is recommended for use with more than one deodorizer or air fresheningappliance, each representative combination of after-market r
10、efill and appliance is to be investigated.4.3 The flash point of an after-market refill liquid shall be conducted in accordance with UL 283, Clause56.1. The resulting flash point shall be not less than 30C (54F) higher than the operating temperature(wick or pad temperature) of the device.4.4 The fla
11、sh point of the liquid need not comply with the 30C temperature differential of Clause 4.3, ifall the following conditions are met:a) The fragrance complies with the flame ignition test in UL 283 Clause 56.2 and;b) The fragrance volume for normal use is less than 300 ml for the total volume; for app
12、lianceswhich utilize more than one fragrance container during normal use, the volume limitation isdetermined as a total of each container of fragrance used with the appliance, and;c) The operating temperature of the heater as determined by the Normal Temperature Test ofUL 283 Section 43 is less than
13、 300C, and;FEBRUARY 11, 2011SUBJECT 283A4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULd) The liquid container is not user refillable.4.5 The flash point of the liquid need not comply with the 30C temperature differential of Clause 4.3, ifth
14、e all following conditions are met:a) The fragrance complies with the flame ignition test in UL 283, Clause 56.2 and;b) The fragrance is subjected to the Ignition Temperature Test, in the Standard for Tests forComparative Flammability of Liquids, UL 340, and the resulting Ignition Temperature is 50C
15、greater than the highest temperature of the following:i) The operating temperature of the wick or pad as determined by the NormalTemperature Test of UL 283 Section 43; or;ii) The fragrance Flash point as determined by the test of UL 283, Clause 56.1.PERFORMANCE5 General5.1 If the after-market refill
16、 is recommended for use with more than one deodorizer or air fresheningappliance, each representative combination of after-market refill and appliance is to be investigated.6 After-market Refill Retention Test6.1 The after-market refill shall be able to be installed onto the specified appliance and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT283A2011OUTLINEOFINVESTIGATIONFORAFTERMARKETREFILLSFORUSEWITHSPECIFICMANUFACTURERSLISTEDDEODORIZERORAIRFRESHENERISSUE1

链接地址:http://www.mydoc123.com/p-1069354.html