UL 60730-2-6 (ND)-2013 National Differences For UL 60730-2-6 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Automatic E.pdf
《UL 60730-2-6 (ND)-2013 National Differences For UL 60730-2-6 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Automatic E.pdf》由会员分享,可在线阅读,更多相关《UL 60730-2-6 (ND)-2013 National Differences For UL 60730-2-6 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Automatic E.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-6Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Automatic Electrical Pressure Sensing Controls Inc
2、luding MechanicalRequirementsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-6Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Automatic Electrical
3、Pressure Sensing Controls Including Mechanical RequirementsEdition: 2Edition Date: October 18, 2013These revisions are being issued to reflect the established effective date for UL60730-2-6.AS OF OCTOBER 19, 2018, THE FIRST EDITION OF UL 60730-2-6 AND THE TWELFTHEDITION OF UL 873 WILL BE WITHDRAWN A
4、ND WILL BE REPLACED BY THISSTANDARD.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any mean
5、s, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no e
6、vent will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been
7、advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and ag
8、ainst any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2014 Underwriters Laboratories Inc.JUNE 10, 2014NATIONAL D
9、IFFERENCES FOR UL UL 60730-2-62UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based s
10、tandards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhi
11、ch would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - T
12、hese are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements
13、.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, su
14、bclause, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is a
15、n altering of the existing base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.JUNE 10, 2014 NATIONAL DIFFERENCES FOR UL UL 60730-2-6 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FUR
16、THER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1.1DV DE Modification of 1.1 of the part 2 by adding the following:Conversions: -60 kPa to -8,71 psi and 4,2 MPa to 609,58 psi.1.1.1DV DE Modification to clarify 1.1.1 of the part 2:In IEC terminology, safety is defined a
17、s an acceptable level of risk. This is consistent withthe intention of UL requirements to reduce the risk of fire, electric shock or injury topersons.4.3.1.101DV D2 Modification of 4.3.1.101 of the part 2 by adding the following note:NOTE In the U.S.A., the number of cycles specified in Annex AA app
18、ly for independently mounted,integrated and incorporated pressure controls.Table 7.2DV D2 Replacement of Table 7.2 of the part 2:Table 7.2DVRequirement Information Clause or subclause MethodModification:Replace the following items by:6 Purpose of control 2.2.101 to 2.2.103,4.3.5, 6.3D26 Number of cy
19、cles of ACTUATION (M) for eachMANUAL ACTION101A)6.10, Annex AA X27 Number of automatic cycles (A) for eachAUTOMATIC ACTION101A)6.11, Annex AA X34 Not applicable37 See additional notes102A), 103A)4, 15, 17 X44 Not applicable48 Operating pressure104A)2.3.11 D(or pressures) 15Additional items: 18101 PR
20、ESSURE MEDIUM 2.3.101 X102 OPERATING DIFFERENTIAL 2.3.26 D103 MAXIMUM WORKING PRESSURE 2.3.29 D104A A low voltage (0 30 volt) cut-out to be wiredwith NEC Class 1 wiring methodsD105A Date code of manufacturing for INDEPENDENTLYMOUNTED CONTROLS105A)CAddition to Note 4:For pressure sensing controls, li
21、mits of activating quantity are specified either in the applicable household appliancepart 2, by the appliance manufacturer or as declared by the pressure sensing control manufacturer (see 17.7 and 17.8).Additional notes:101A)The minimum number of cycles for independently mounted, integrated and INC
22、ORPORATED CONTROLS are indicated inAnnex AA.JUNE 10, 2014NATIONAL DIFFERENCES FOR UL UL 60730-2-64Table 7.2DV Continued on Next PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 7.2DV ContinuedRequirement Information Clause or subclaus
23、e Method102A)For Type 2 controls, the required deviations and DRIFT tolerances are indicated in Table AA.101DV.103A)Deviation and DRIFT applies to a SPDT cutout terminal which is de-energized on pressure rise.105A)The date code shall be the date or other dating period of manufacture not exceeding an
24、y three consecutivemonths. The date of manufacture may be abbreviated; or may be in a nationally accepted conventional code or in acode affirmed by the manufacturer, provided that the code:a) Does not repeat in less than 20 years, andb) Does not require reference to the product records of the manufa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6073026ND2013NATIONALDIFFERENCESFORUL6073026STANDARDFORAUTOMATICELECTRICALCONTROLSFORHOUSEHOLDANDSIMILARUSEPART2PARTICULARREQUIREMENTSFORAUTOMATICEPDF

链接地址:http://www.mydoc123.com/p-1068498.html