UL 2459-2008 UL Standard for Safety Insulated Multi-Pole Splicing Wire Connectors (First Edition Reprint with revisions through and including January 31 2014)《绝缘的多极分线连接器》.pdf
《UL 2459-2008 UL Standard for Safety Insulated Multi-Pole Splicing Wire Connectors (First Edition Reprint with revisions through and including January 31 2014)《绝缘的多极分线连接器》.pdf》由会员分享,可在线阅读,更多相关《UL 2459-2008 UL Standard for Safety Insulated Multi-Pole Splicing Wire Connectors (First Edition Reprint with revisions through and including January 31 2014)《绝缘的多极分线连接器》.pdf(64页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2459 Insulated Multi-Pole Splicing Wire ConnectorsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHOR
2、IZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Insulated Multi-Pole Splicing Wire Connectors, UL 2459 First Edition, Dated August 22, 2008 Summary of Topics This revision is being issued to clarify the scope, editorial changes, revisions to the sa
3、mpling requirements, and mechanical sequence. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. The revisions are substantially in accordance with Proposal(s) on this subject dated September 20, 2013. All rights res
4、erved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or
5、implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of t
6、he use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic
7、 versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on
8、 the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the preface. The prior text for requirements that have been revised and that
9、 have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. JANUARY 31, 2014 UL 2459 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 31, 2014 UL 2459 tr2 No Text on This Page
10、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Canadian Standards Association CSA C22.2 No. 2459-08 First Edition Underwriters Laboratories Inc. UL 2459 First Edition Insulated Multi-Pole Splicing Wire Connectors August 22, 2008 (Title Page
11、 Reprinted: January 31, 2014) ANSI/UL 2459-2014UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard is issued jointly by the Canadian Standards Association (CSA) and Underwriters Laboratories Inc. (UL). Com
12、ments or proposals for revisions on any part of the standard may be submitted to CSA or UL at any time. Revisions to this standard will be made only after processing according to the standards development procedures of CSA and UL. CSA and UL will issue revisions to this standard by means of a new ed
13、ition or revised or additional pages bearing their date of issue. ISBN 1-55436-435-3 2008 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. To purchase CSA Standards and related publications, visit CSAs
14、Online Store at www.ShopCSA.ca or call toll-free 1-800-463-6727 or 416-747-4044. Copyright 2014 Underwriters Laboratories Inc. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ow
15、nerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety consists of the First edition including revisions through January 31, 2014. The most recent designation of ANSI/UL 2459 as an American National Standard (ANSI) occurred
16、 on January 31, 2014. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request
17、 in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. To purchase UL Standards, visit Comm 2000 at http:/m- or call toll-free 1-888-853-3503.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface .5 1 Scope .
18、6A 2 Reference publications and denitions .8 2.1 Reference publications 8 2.2 Denitions .9 3 Units of measurement 11 4 Construction .11 4.1 General 11 4.2 Materials .12 4.3 Accessibility of parts .14 4.4 Spacings .15 4.5 Mating-type (separable-type) connectors .16 4.6 Integral pigtail leads .16 5 Te
19、st requirements 16 5.1 General 16 5.2 Grounding contact Short-time withstand current .17 5.3 Latching mechanism .17 5.4 Abnormal overload 18 5.5 Temperature 18 5.6 Dielectric voltage withstand .18 5.7 Dielectric withstand Puncture 19 5.8 Mold stress relief 19 5.9 Current cycling 20 5.10 Mechanical s
20、equence .21 5.11 Stress corrosion/moist ammonia (NH 4 )21 5.12 Stress corrosion/mercurous nitrate (HgNO 3 ) .21 5.13 Spring action 21 6 Sampling requirements .21 7 Test methods 22 7.1 General 22 7.2 Grounding contact Short-time withstand current .28 7.3 Latching or locking mechanism 29 7.4 Abnormal
21、overload 29 7.5 Temperature rise 30 7.6 Dielectric voltage withstand .31 7.7 Dielectric withstand Puncture 31 7.8 Mold stress relief 32 7.9 Current cycling 32 7.10 Mechanical sequence .33 7.11 Stress corrosion/moist ammonia (NH 4 )34 7.12 Stress corrosion/mercurous nitrate (HgNO 3 ) .35 7.13 Spring-
22、action sequence .35 8 Marking, labelling, and packaging 36 TABLES .39 FIGURES 47 JANUARY 31, 2014 CSA C22.2 NO. 2459-08 UL 2459 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Annex A (Informative) A.1 Example of a stability factor calculat
23、ion .54 Annex B (Informative) B.1 Example of application of Clause 7.10.2.4 55 Annex C (Informative) C.1 French translations and markings (See Clause 8.) .56 AUGUST 22, 2008 CSA C22.2 NO. 2459-08 UL 2459 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISS
24、ION FROM UL Preface This is the harmonized CSA Group and UL standard for insulated multi-pole splicing wire connectors. It is the rst edition of CSA C22.2 No. 2459 and the rst edition of UL 2459. This harmonized standard has been jointly revised on January 31, 2014. This harmonized standard was prep
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL24592008ULSTANDARDFORSAFETYINSULATEDMULTIPOLESPLICINGWIRECONNECTORSFIRSTEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJANUARY312014

链接地址:http://www.mydoc123.com/p-1067930.html