UL 2459 CRD-2010 UL Standard for Safety Insulated Multi-Pole Splicing Wire Connectors - Section Paragraph Reference Par 1 3 Subject a) LED Retrofit Application Addition to Scope b.pdf
《UL 2459 CRD-2010 UL Standard for Safety Insulated Multi-Pole Splicing Wire Connectors - Section Paragraph Reference Par 1 3 Subject a) LED Retrofit Application Addition to Scope b.pdf》由会员分享,可在线阅读,更多相关《UL 2459 CRD-2010 UL Standard for Safety Insulated Multi-Pole Splicing Wire Connectors - Section Paragraph Reference Par 1 3 Subject a) LED Retrofit Application Addition to Scope b.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): ZMNA/ZMNA7Standard Number: UL 2459Edition Date: August 22, 2008Edition Number: 1Section / Paragraph Reference: Par. 1.3Subject: a) LED Retrofit Application A
3、ddition to Scope; b) Allowabale attachmentdirectly to branch circuit except for interrupting of circuitSupercedes prior Certification Requirement Decision issued 2010-07-20DECISION:1.3 These wire connectors requirements also cover Luminaire disconnects that are may additionally beused:(a) internal t
4、o luminaries to facilitate replacement of the ballast, or(b) for LED retrofit applications.Luminaire disconnects are and may not be to be directly attached to the branch circuit conductors for thepurpose of interrupting (making and breaking) branch circuit conductors These wire connectorsLuminaire d
5、isconnects are suitable for may have one or more conductors per contact.RATIONALE FOR DECISION:a) As noted in clause 1.3 of UL 2459, Luminaire Disconnects were initially used internal to luminaries,such as a fluorescent luminaire, to facilitate replacement of the ballast. These products are now used
6、 toretrofit LED modules with an Edison screw base adaptor. These LED retrofits use a power supply ratherthan a ballast.While a luminaire connector was not covered for an LED retrofit application, the concept and overallsimilarity of application, ballast vs. power supply, has been used by the UL as r
7、ationale to accept thisconnector in LED retrofit applications. Consequently, an expansion of clause 1.3 is proposed to addressthis allowance.Clause 1.3 is being revised to more clearly address the Luminaire application.b) Clause 1.3 of standard 2459 states that Ballast Disconnect type connectors may
8、 not be directlyattached to the branch circuit conductors. When this was first discussed, it was intended that this wouldprevent the Ballast Disconnect connector from being used to splice branch circuit conductors together.Ballast Disconnect connectors should not be used as a splicing wire connector
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL2459CRD2010ULSTANDARDFORSAFETYINSULATEDMULTIPOLESPLICINGWIRECONNECTORSSECTIONPARAGRAPHREFERENCEPAR13SUBJECTALEDRETROFITAPPLICATIONADDITIONTOSCOPEBPDF

链接地址:http://www.mydoc123.com/p-1067929.html