《UL 244A CRD-2012 UL Standard for Safety Solid-State Controls for Appliances - Section Paragraph Reference 24 3 Subject Abnormal Switching Test - Requirements for controls using el.pdf》由会员分享,可在线阅读,更多相关《UL 244A CRD-2012 UL Standard for Safety Solid-State Controls for Appliances - Section Paragraph Reference 24 3 Subject Abnormal Switching Test - Requirements for controls using el.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): ATNZStandard Number: UL 244AEdition Date: April 30, 2003Edition Number: 3Section / Paragraph Reference: 24.3Subject: Abnormal Switching Test - Requirements f
3、or controls using electronictriggering techniques, such as zero-crossing switching, to switch the controlsoutput switching device.DECISION:(NEW SECTION)24.3 Abnormal Switching Test24.3.1 Controls incorporating electronic circuitry to trigger the switching device during a moreadvantageous electrical
4、condition, such as at zero crossing, shall be subjected to this abnormal switchingtest. This test is applicable when:a) Loads and circuits are non-safety.b) Switching components are used beyond their ratings.24.3.2 Two test samples are prepared and connected as follows:a) The trigger circuit of the
5、switching device is to be removed or modified to allow randomswitching.b) A ground arc indicating fuse is connected to accessible dead metal of the control. Theground arc detection fuse shall be rated not greater than 3A and not less than the workingvoltage.c) The control shall be covered in a singl
6、e layer of cheesecloth except the mounting surface,and then placed on a softwood surface that has been covered with white tissue paper. Thecheesecloth requirements shall be according to 21.3.d) The rated supply shall be connected through a Branch Circuit Protection device sizedaccording to installat
7、ion requirements.e) The control is connected to its rated electrical load.24.3.3 The prepared test samples shall be operated in accordance with the endurance test requirementsspecifying the number of operating cycles and on/off periods using random switching. The test samplesshall be operated until
8、either the required number of endurance test cycles are achieved or until ultimateresults are demonstrated for 1h stabilized duration.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL24.3.4 Immediately after each abnormal switching test, each c
9、ontrol shall be subjected to the DielectricVoltage-Withstand Test, Section 33.24.3.5 The control shall either operate as intended in accordance with the endurance test requirements,or demonstrate an end-of-life fail safe condition with no evidence of an imminent electrical shock, fire orinjury to pe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL244ACRD2012ULSTANDARDFORSAFETYSOLIDSTATECONTROLSFORAPPLIANCESSECTIONPARAGRAPHREFERENCE243SUBJECTABNORMALSWITCHINGTESTREQUIREMENTSFORCONTROLSUSINGELPDF

链接地址:http://www.mydoc123.com/p-1067927.html