《UL 2272 CRD-2018 UL Standard for Safety Electrical Systems for Personal E-Mobility Devices - Section Paragraph Reference 9 16 24 26 27 28 Subject Clarification of Requirement for .pdf》由会员分享,可在线阅读,更多相关《UL 2272 CRD-2018 UL Standard for Safety Electrical Systems for Personal E-Mobility Devices - Section Paragraph Reference 9 16 24 26 27 28 Subject Clarification of Requirement for .pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): FKIS, FKIS7Standard Number: UL 2272Standard Title: Standard for Electrical Systems for Personal E-Mobility DevicesEdition Date: November 21, 2016Edition Number: 1Section / Paragraph Reference: 9, 16,
3、24, 26, 27, 28Subject: Clarification of Requirement for Personal E-mobility Device Powered byLead-Acid BatteryDECISION:9 Enclosures9.1 General9.1.5 For personal e-mobility devices powered by lead acid batteries, openings in the enclosure shall beconstructed to prevent accumulation of flammable gases
4、 that could lead to a hazardous condition fromconcentrations of hydrogen gas due to electrolysis of aqueous electrolytes greater than 25% of the LFLof hydrogen (equivalent to 1% concentration in a volume of air). Ventilation openings shall have aminimum opening area of:A=0.005NC5(cm2)Where:A = Total
5、 cross sectional area of ventilation holes required (cm2)N = Number of cells in batteryC5= Capacity of battery at the 5-h rate (Ah)Exception No. 1: The area of ventilation openings can be reduced if it can be demonstrated that there issufficient ventilation within the device to prevent hydrogen accu
6、mulations above 25% of the LFL ofhydrogen during overcharging test and imbalanced charging test. If this exception is used to determinethe compliance, a gas monitor suitable for detecting 25% of the lower flammability limit (LFL) of thehydrogen is to be used to measure the concentration of hydrogen
7、during the overcharge test andimbalanced charging test. A minimum of two sampling locations where concentrations may occur such asat vent openings or vent ducts shall be used for taking measurements.16 Protective Circuits and Safety Analysis16.1 The personal e-mobility devices protective circuitry s
8、hall maintain the cells within their specifiedoperating region for charging and discharging through the life of the device. If cell specified operatinglimits are exceeded, the protective circuitry shall limit or shut down the charging or discharging to mitigateexcursions beyond specified operating l
9、imits. Compliance is determined through a review of the cellspecifications and safety analysis of 16.2 and through the testing of this standard. If applicable to theUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULpersonal e-mobility device des
10、ign, the analysis and testing needs to evaluate the overcharge protectioncontrols ability to mitigate overcharge due to regenerative charging during use. Chargers withstandardized output connectors (e.g. USB connectors, 3-pin round dc “aviation” connectors that mayresult in the use of unspecified ch
11、argers shall not be considered as a reliable control to prevent anovervoltage or overcurrent condition.16.1.1 Since it is not practical to monitor and control individual cells of a monobloc battery, personale-mobility devices using lead-acid batteries as the power source shall protect the batteries
12、fromovercharge through voltage protection and from overheating through either current protection ortemperature protection or both.16.5 Devices relied upon for critical safety as noted in 16.4(a) - (b) shall minimally comply with theapplicable Environmental Stress tests described in Sections9-22ofthe
13、StandardforTests forSafety-Related Controls Employing Solid-State Devices, UL 991, or fully comply with appropriatefunctional safety requirements below. Devices solely relied upon for critical safety as noted in 16.4 (c)shall fully comply with appropriate functional safety requirements in one of the
14、 following standards asappropriate to the design of the electronic and software protection scheme:a) The Standard for Tests for Safety-Related Controls Employing Solid-State Devices, UL 991,or the Standard for Safety Functions Incorporating Electronic Technology, CSA-C22.2 No. 0.8,and the Standard f
15、or Software in Programmable Components, UL 1998;b) The Standard for Automatic Electrical Controls for Household and Similar Use - Part 1:General Requirements, UL 60730-1 or CAN/CSA-E60730-1; andc) The Standard for Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Syst
16、ems - Part 1: General Requirements, IEC 61508-1, and all parts.Exception: For lead acid batteries, this requirement does not apply.24 Overcharge Test24.2 A fully charged sample is to be discharged at a 0.2 C constant discharge rate or a higher dischargerate permitted by the cell manufacturer to the
17、manufacturers specified EODV. The DUT is then subjectedto a constant current charging at the cell manufacturers maximum specified charging rate and under asingle fault condition in the charging protection circuitry that could lead to an overcharge condition.Protective devices that have been determin
18、ed reliable may remain in the circuit as noted in 20.5. Forinformation purposes, temperatures are to be monitored on the cell/module where temperatures may behighest. The output control circuitry of external chargers with standardized output connectors (e.g. USBconnectors, standardized round dc “avi
19、ation” connectors) that may result in the use of unspecifiedchargers shall not be considered as a reliable control to prevent an overcharging condition, and for thistest, the charger shall be replaced with a power supply capable of delivering 110% of the specified upperlimit charging voltage during
20、the test. Voltages on cells/cell blocks are to be monitored during the test andfor lead acid batteries, voltages on the batteries are to be monitored.24.3 The test is to be continued until the voltage has reached 110% of the specified upper limit chargingvoltage or the maximum obtainable charging vo
21、ltage (if the 110% of specified upper limit charging voltagecannot be reached due to remaining protection circuitry), and monitored temperatures return to ambientor steady state conditions and an additional 2 h has elapsed, or explosion/fire occur. If the DUT isoperational after the test, it shall b
22、e subjected to a minimum of one charge/discharge cycle at the cellmanufacturers maximum specified values per Section 22, Post Test Cycle. The test shall be followed byan observation period per 20.7.STANDARD NUMBER: UL 2272 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBU
23、TION WITHOUT PERMISSION FROM UL24.6 As a result of the overcharge test, any of the following results in (a) - (e) below are considered anon-compliant result. See also Table 22.1 and Section 23, Results Criteria.a) E - Explosion;b) F - Fire;c) R - Rupture (enclosure);d) L - Electrolyte Leakage (exter
24、nal to enclosure); ande) S - Electric shock hazard (resistance below isolation resistance limits or dielectricbreakdown).For lead-acid battery, the maximum voltage measured on the battery shall not exceed the specified upperlimit charging voltage for the battery.For other batteries, the voltage limi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL2272CRD2018ULSTANDARDFORSAFETYELECTRICALSYSTEMSFORPERSONALEMOBILITYDEVICESSECTIONPARAGRAPHREFERENCE91624262728SUBJECTCLARIFICATIONOFREQUIREMENTFORPDF

链接地址:http://www.mydoc123.com/p-1067888.html