TIA TSB62-7-2000 ITM-7 Characterization of Fiber Strip Damage by Dynamic Tensile Testing《ITM-7 用动态伸长测试的光纤剥去损害特征》.pdf
《TIA TSB62-7-2000 ITM-7 Characterization of Fiber Strip Damage by Dynamic Tensile Testing《ITM-7 用动态伸长测试的光纤剥去损害特征》.pdf》由会员分享,可在线阅读,更多相关《TIA TSB62-7-2000 ITM-7 Characterization of Fiber Strip Damage by Dynamic Tensile Testing《ITM-7 用动态伸长测试的光纤剥去损害特征》.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、TIA/EIA TELECOMMUNICATIONS SYSTEMS BULLETIN ITM-7 Characterization of Fiber Strip Damage by Dynamic Tensile Testing TSB62-7 APRIL 2000 TELECOMMUNICATIONS INDUSTRY ASSOCIATION Representing the telecommunications indushy in association with the Electronic Industries Aiance Elsctronk Industrias- Allian
2、ce NOTICE TWEIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimu
3、m delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of TWEIA rom manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and P
4、ublications preclude their voluntary use by those other than TWEIA members, whether the standard is to be used either domestically or internationally. Standards, Publications and Bulletins are adopted by EIA in accordance with the American National Standards Institute (ANSI) patent policy. By such a
5、ction, TWEIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard, Publication, or Bulletin. Technical Bulletins are distinguished rom TWEIA Standards or Interim Standards, in that they contain a compilation of engineering dat
6、a or information useful to the technical community, and represent approaches to good engineering practices that are suggested by the formulating committee. This Bulletin is not intended to preclude or discourage other approaches that similarly represent good engineering practice, or that may be acce
7、ptable to, or have been accepted by, appropriate bodies. Parties who wish to bring other approaches to the attention of the formulating committee to be considered for inclusion in future revisions of this Bulletin are encouraged to do so. It is the intention of the formulating committee to revise an
8、d update this Bulletin rom time to time as may be occasioned by changes in technology, industry practice, or government regulations, or for other appropriate reasons. (From Project No. 361 8, formulated under the cognizance of the TIA FO-6.6 Subcommittee on Fibers and Materials.) Published by TELECO
9、MMUNICATIONS INDUSTRY ASSOCIATION 2000 Standards and Technology Department 2500 Wilson Boulevard Arlington, VA 2220 1 PRICE: Please refer to the current Catalog of ELECTRONIC INDUSTRIES ALLIANCE STANDARDS and ENGINEERING PUBLICATIONS or call Global Engineering Documents, USA and Canada (1-800-854-71
10、79) International (303-397-7956) All rights reserved Printed in U.S.A. TINE IA-TSB-62-7 ITM-7 Characterization of fiber strip damage by dynamic tensile testing Contents Section Fiqure 1 2 3 4 5 6 Annex A Foreword Introduction Normative references Apparatus Sampling and specimens Procedu re Calculati
11、ons or interpretation of results Documentation Fi ber- holding fixture Strip length for end-stripping Strip length for center-stripping Fiber mounted on holding fixture Tensile test setup for end-stripping Tensile test setup for center-stripping Comparison with IEC and ITU Paqe iii 1 2 2 3 5 9 9 10
12、I TINEIA-TSB-62-7 rhis page left blank. II TINE IA-TSB-62-7 ITM-7 Characterization of fiber strip damage by dynamic tensile testing Foreword This Informative Test Method comes from TIA Project No. 3618, and was formulated under the cognizance of TIA FO-6.6, Subcommittee on Optical Fibers, and of FO-
13、6.6.8, Working Group on Fiber Reliability This ITM is part of the series of informative test methods included within TINEIA-TSB-62. There is one informative annex. Keywords: fiber stripping, fiber splicing . 111 TINEIA-TSB-62-7 rhis page left blank. IV TINE IA-TSB-62-7 ITM-7 Characterization of fibe
14、r strip damage by dynamic tensile testing 1 Introduction 1.1 Intent This method characterizes the tensile strength of stripped optical fiber. The results of this test provide an indication of the mechanical damage that is attributable to the stripping operation. 1.2 Scope An ideal coating removal pr
15、ocedure should be able to remove the protective coating without damaging the surface of the glass fiber with a nick or scratch. Practical stripping tools and/or stripping procedures (abbreviated to ?strippers?) may produce surface flaws that increase in size and weaken with stress and humidity, ther
16、eby lowering the tensile strength of the fiber, and increasing the risk of fiber failure. 1.3 Stripping methods Fiber coatings may be removed with a stripper or with a chemical solution. For most field applications the coating is removed from the end of the fiber (end-strip) with a stripper. Center-
17、stripping entails removing a length of coating while leaving the fiber coating intact on both sides of the stripped portion. Many mechanical and most chemical strippers may be capable of center-stripping. Center-stripped fiber is relatively easier to load and test without doing additional damage. Se
18、lection of the test method depends upon the information desired. technique, large coatings Design - operator 1.4 Variables Fiber strip damage depends on the fiber coating, the stripper (design, condition, age), wiping (dry wipe, wet wipe, number of wipes), and operator skill. 1 TINEIA-TSB-62-7 1.5 F
19、ailure modes Potential failure modes tested by this method include, but are not limited to: 0 Fiber breakage 0 Reduction in fiber tensile strength 2 Normative references Test requirements may include, but are not limited to, the most recent editions of the following references: FOTP-28 (EIMIA-455-28
20、C) Measuring dynamic strength and fatigue parameters of optical fibers by tension FOTP-I 78 (ElMIA-455-1 78B) Measurement of strip force required for mechanically removing coatings from optical fibers 3 Apparatus 3.1 Test Equipment Unless otherwise specified, equipment requirements shall be as speci
21、fied in clause 3 of FOTP- 28. 3.2 Strain Rate Use a tensile tester capable of imparting a constant strain rate of 2.5 to 5.0 %/min., without jerking, to the fiber under test. 3.3 Fiber holding fixture for end-strip method Mount the test fiber on a fiber holding fixture, typically made of paper, cons
22、truction paper, cardboard, or poster board, as shown in Figure 1. The holding fixture allows stress to be transferred to the fiber without producing damage by gripping stripped fiber. It must be made of material that allows the fiber to be glued to it and that can be cut. 2 TINE IA-TSB-62-7 7 20mmx3
23、0mm i cut-out i i, a 90mm Figure 1 - Fiber-holding fixture -A- 40 mm . 4 Sampling and specimens 4.1 Representative specimens: fiber and stripper The specimens shall be representative of both the fiber and the stripper under test. 4.2 Strip length The fiber surface area subjected to possible strip da
24、mage is proportional to the strip length. Fiber strip length (before cleaving) is influenced by the following factors: The amount of stripped fiber required by the splicing system (after cleaving the fiber to I engt h) 0 The minimum length of fiber required for cleaving Stripper restrictions Operato
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- TIATSB6272000ITM7CHARACTERIZATIONOFFIBERSTRIPDAMAGEBYDYNAMICTENSILETESTINGITM7 动态 伸长 测试 光纤 剥去 损害 特征 PDF

链接地址:http://www.mydoc123.com/p-1059841.html