SAE J 2913-2016 R-1234yf [HFO-1234yf] Refrigerant Electronic Leak Detectors Minimum Performance Criteria.pdf
《SAE J 2913-2016 R-1234yf [HFO-1234yf] Refrigerant Electronic Leak Detectors Minimum Performance Criteria.pdf》由会员分享,可在线阅读,更多相关《SAE J 2913-2016 R-1234yf [HFO-1234yf] Refrigerant Electronic Leak Detectors Minimum Performance Criteria.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2016 SAE InternationalAll rights reserved. No part of this publi
3、cation may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (out
4、side USA)Fax: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visitHTTP:/STANDARDS.SAE.ORG/J2319_201610SURFACE VEHICLESTANDARDJ2913 OCT2016Issued 2011-02Revised 2016-10Superseding J2913 FEB2011R-123
5、4yf HFO-1234yf Refrigerant Electronic Leak Detectors, Minimum Performance CriteriaRATIONALEModification of this standard to include “Definition of Equipment Used for Certification” for prototype or preproduction product used for certification as stated in SAE J2911. In addition, modification to incl
6、ude certification grace period and recertification requirements for the specific revision to this standard.1. SCOPEThis SAE Standard provides testing and functional requirements to meet specified minimum performance criteria for electronic probe-type leak detectors. The equipment specified here will
7、 identify smaller refrigerant leaks when servicing motor vehicle air conditioning systems, including those engineered with improved sealing and smaller refrigerant charges to address environmental concerns and increase system efficiency. This document does not address any safety issues concerning th
8、e equipment design or use beyond that of sampling a flammable refrigerant save those described in 3.1 and 3.2 of this document. All requirements of this standard shall be verified in SAE J2911.1.1 PurposeThe purpose of this SAE Standard is to establish minimum performance criteria for a modern class
9、 of electronic probe- type leak detectors intended for use in automotive air conditioning systems with R-1234yf, an A2L flammable refrigerant.1.2 Grace PeriodThis revision is subject to a 0 day grace period from the date of publication. After the grace period, only the most recent version of this st
10、andard may be used for certification and/or recertification. To certify equipment to the prior version of this standard, actual laboratory testing, not merely the signing of a contract, etc. must have begun prior to the publication date of this new version. No laboratory certification to any prior v
11、ersion of this standard, shall be accepted by SAE for listing under the provisions of J2911 after 90 days from the publication date of this revision.SAE INTERNATIONAL J2319 OCT2016 Page 2 of 132. REFERENCES 2.1 Applicable DocumentsThe following publications form a part of this specification to the e
12、xtent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply.2.1.1 SAE PublicationsAvailable from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or +1 724-776-4970 (outside USA), www.sae.org.SAE
13、J639 Safety Standards for Motor Vehicle Refrigerant Vapor Compression Systems SAE J2791 HFC-134a Refrigerant Electronic Leak Detectors, Minimum Performance CriteriaSAE J2845 R-1234yf HFO-1234yf and R-744 Technician Training for Service and Containment of Refrigerants Used in Mobile A/C SystemsSAE J2
14、911 Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J StandardsSAE J1739 Potential Failure Mode and Effects Analysis in Design (Design FMEA), Potential Failure Mode and Effects Analysis in Manufa
15、cturing and Assembly Processes (Process FMEA)3. TECHNICAL REQUIREMENTS3.1 The detector shall be tested to meet the performance specifications of this standard by an independent testing facility as defined in SAE J2911, and in accordance with the procedures set for in SAE J2911. The independent testi
16、ng facility shall maintain all documentation related to its testing, including calibration and maintenance data for its equipment, for a period of five years following the test of the specific detector. 3.1.1 The manufacturer may state certification of compliance with this Standard (including use of
17、 any labeling) only after meeting the requirements in SAE J2911 “Procedure for Certification That Requirements for Mobile Air Conditioning System Components, Service Equipment and Service Technicians Meet SAE J Standards”. See Appendix B.3.1.2 To certify pre-production or prototype units as defined
18、in SAE J2911, they shall not be marketed with a label indicating that they meet the appropriate SAE standard until the following requirement is met. The SAE label shall not be applied to these units until the independent laboratory has confirmed that the manufacturer has made, in one months serial p
19、roduction, at least 150 completed serial production units.3.2 The detector shall be suitable for use in safely identifying R-1234yf an A2L flammable refrigerant. As a safety factor against use of a more flammable refrigerant in vehicle service, the marketer shall certify that at peak sensitivity, th
20、e temperature anywhere within the detector does not exceed 400 C (752 F) so that ignition cannot occur. This shall be verified by prolonged exposure of any component subject to producing high temperature to a flammable propane-air mixture, such as from a propane torch. 3.2.1 If any components may op
21、erate at that temperature or above, they shall meet ANSI/ISA 12.12.01 and/or be enclosed or housed in a location within the detector that will, in case of separation at any connections within the refrigerant sampling flow route, prevent refrigerant from coming into contact with same.3.2.2 If any com
22、ponents, such as switches, solenoids and motors, come into contact with the refrigerant sample, they shall be of arc-suppression design as specified in ANSI/ISA12.12.01. 3.2.3 The detector shall be suitable for use in an automotive service garage and operate in ambient temperatures of 15 to 49 C (59
23、 to 120 F).SAE INTERNATIONAL J2319 OCT2016 Page 3 of 133.3 The detector shall have at least three scales that can be manually selected: (1) 4 g/year (0.15 ounce/year); (2) 7 g/year (0.25 ounce/year); (3) 14 g/year (0.5 ounce/year).3.4 If it passes, the detector shall carry a label that states “Desig
24、n certified by (name of independent testing laboratory) to meet SAE J2913 with lettering in bold face type at least 3 mm high.3.5 If it does not pass, the detector may be retested subject to the limits of Section 10. If a detector fails beyond these retest limits, it may be retested only after the m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ29132016R1234YFHFO1234YFREFRIGERANTELECTRONICLEAKDETECTORSMINIMUMPERFORMANCECRITERIAPDF

链接地址:http://www.mydoc123.com/p-1027692.html