SAE J 2296-2012 Retest of Refrigerant Container《制冷剂容器的重新测试》.pdf
《SAE J 2296-2012 Retest of Refrigerant Container《制冷剂容器的重新测试》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2296-2012 Retest of Refrigerant Container《制冷剂容器的重新测试》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2012 SAE International All rights reserved. No part of this pub
3、lication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970
4、(outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J2296_201206SURFACEVEHICLESTANDARDJ2296 JUN2012 Issued 1996-09Revised 2012-06Superse
5、ding J2296 NOV1998 Retest of Refrigerant Container RATIONALEThis standard has been updated to update references and clarify regional requirements as well as the five year re-test requirement.1. SCOPE To provide a procedure to inspect a refrigerant cylinder used in equipment servicing mobile air-cond
6、itioning (A/C) systems. This includes the pressure cylinder used for refrigerant recovery/recycling and charging equipment. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue
7、 of SAE publications shall apply. 2.1.1 CGA Specifications Available from Compressed Gas Association, Crystal Square #2, Jefferson Davis Highway, Arlington, VA 22202-4102. CGA S-1.1 Pressure Relief Device Standards - Cylinders for Compressed Gases CGA C-6 Standards for Visual Inspection of Steel Com
8、pressed Gas Cylinders CGA C-6.1 Standards for Visual Inspection of High Pressure Aluminum Compressed Gas Cylinders 2.1.2 DOT Specifications Available from the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402. DOT 39 DOT approved cylinder specifications (except those
9、 operating under exemptions) are found in 49 Code of Federal Regulations (CFR) sections 178.1 through 178.68. SAE J2296 Revised JUN2012 Page 2 of 7 2.1.3 Underwriters Laboratories Available from Underwriters Laboratories, 333 Pfingsten Road, Northbrook, IL 60062-2096. UL 1769 Cylinder Valves UL 1963
10、 Standard for Refrigerant Recovery/Recycling Equipment, First Edition 1993, Copyright 1989 2.2 Related Publications The following publications are provided for information purposes only and are not a required part of this SAE Technical Report.2.2.1 SAE Publications Available from SAE International,
11、400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.SAE J513 Refrigeration Tube Fittings - General Specifications SAE J1990 Recovery and Recycle Equipment for Mobile Automotive Air-Conditioning Systems SAE J2197 HFC-
12、134a (R-134a) Service Hose Fittings for Automotive Air-Conditioning Service Equipment SAE J2209 CFC-12 (R-12) Refrigerant Recovery Equipment for Mobile Automotive Air-Conditioning Systems SAE J2210 HFC-134a (R-134a) Recovery/Recycling Equipment for Mobile Air-Conditioning Systems 2.2.2 ARI Publicati
13、on Available from ARI, 4301 North Fairfax Drive, Suite 425, Arlington, VA. ARI Guideline K 1990 Cylinders for Recovered Fluorocarbon Refrigerants 2.2.3 DOT Publication Available from the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402. Part III Environmental Protec
14、tion Agency, 40CFR Part 82 - Protection of Stratospheric Ozone: Labeling Supplemental Proposal Final Rule SAE J2296 Revised JUN2012 Page 3 of 7 3. STORAGE CONTAINERS (CYLINDER/TANK) 3.1 Federal Requirements The container stores the refrigerant and protects it from outside contamination. Most refrige
15、rants are under pressure at ambient temperatures. Refrigerants should never be charged and stored in unapproved containers such as DOT Specification 39 disposable cylinders. 3.1.1 DOT Stands for the U.S. Department of Transportation Federal law forbids transporting DOT 39 cylinders if refilled and p
16、enalties up to a $25 000 fine and 5 years imprisonment may be expected (Title 49 U.S.C. (United States Code) Sec. 1809).3.1.2 Proper storage containers are DOT approved refillable containers which are stamped with the information in Figure 1: FIGURE 1 - INFORMATION FOR CONTAINERS 3.1.2.1 The sample
17、information is for a tank commonly called a “50-lb tank.” Other size tanks shall have the appropriate W.C. and T.W. markings. 3.1.3 The first line is the DOT code for a container rated at 400 psig (2760 kPa) or 302 psig (2084 kPa) or 350 psig (2415 kPa) working pressure. 3.1.3.1 The second line is t
18、he container manufacturer serial number. 3.1.3.2 The third line is the container manufacturer identification number. 3.1.3.3 The fourth line W.C. is the water capacity in pounds when completely filled and T.W. is the cylinder tare weight in pounds. Since common refrigerants are heavier than water, t
19、his tank can safely be filled with 23 kg for CFC-12 (R-12) or 21 kg of HFC-134a (R-134a). 3.1.3.4 The fifth line is the manufacturers date code, which is important for the retested date. 3.2 The containers and valves should meet UL 1963 which requires that: 3.2.1 The storage container shall comply w
20、ith DOT Specifications, 49 CFR, and have a service pressure rating not less than the recovery equipments pressure limiting device. 3.2.2 The cylinder valve shall comply with the Standard for Cylinder valves, UL 1769. The pressure relief device shall comply with the Pressure Relief Device Standard Pa
21、rt 1 - Pressure Relief Device Standards - Cylinders for Compressed Gases”, Compressed Gas Association Pamphlet S-1.1. 3.2.3 The tank assembly shall be marked to indicate the first retest date, which shall be 5 years from date of manufacture. Also the marking shall indicate that retest must be perfor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ22962012RETESTOFREFRIGERANTCONTAINER 制冷剂 容器 重新 测试 PDF

链接地址:http://www.mydoc123.com/p-1026839.html